• 제목/요약/키워드: Capacitively coupled electrode

검색결과 40건 처리시간 0.029초

Multi-hole RF CCP 방전에서 방전 주파수가 미치는 영향

  • 이헌수;이윤성;서상훈;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.145-145
    • /
    • 2011
  • Recently, multi-hole electrode RF capacitively coupled plasma discharge is being used in the deposition of microcrystalline silicon for thin film solar cell to increase the speed of deposition. To make efficient multi-hole electrode RF capacitively coupled plasma discharge, the hole diameter is to be designed concerning the plasma parameters. In past studies, the relationship between plasma parameters such as pressures and gas species, and hole diameter for efficient plasma density enhancement is experimentally shown. In the presentation, the relationship between plasma deriving frequency and hole diameter for efficient multi-hole electrode RF capacitively coupled plasma discharge is shown. In usual capacitively coupled plasma discharge, plasma parameter, such as plasma density, plasma impedence and plasma temperature, change as frequency increases. Because of the change, the optimum hole diameter of the multi-hole electrode RF capacitively coupled plasma for high density plasma is thought to be modified when the plasma deriving frequency changes. To see the frequency effect on the multi-hole RF capacitively coupled plasma is discharged and one of its electrode is changed from a plane electrode to a variety of multi-hole electrodes with different hole diameters. The discharge is derived by RF power source with various frequency and the plasma parameter is measured with RF compensated single Langmuir probe. The shrinkage of the hole diameter for efficient discharge is observed as the plasma deriving frequency increases.

  • PDF

용량성 결합 능동 전극의 내부 잡음 분석 (A Study on Intrinsic Noise of Capacitively Coupled Active Electrode)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제13권1호
    • /
    • pp.44-49
    • /
    • 2012
  • 간접접촉 심전도 측정(Indirect-Contact ECG)은 일상생활에서의 무구속 무자각 측정에 적합한 새로운 심전도 측정 방법이다. 간접접촉 심전도 측정 에 서 관측되는 큰 배경 잡음을 줄이기 위한 기초 연구로서, 본 연구에서는 간접 접촉 심전도에서 사용되는 용량성 결합 능동 전극(Capacitively coupled active electrode)의 열잡음(Thermal Noise) 모델을 구성하였다. 실험을 통해, 용량성 결합 능동 전극만의 배경 잡음의 크기가 열잡음 모델에서 예상한 수준과 거의 일치함을 확인하였다. 면으로 된 직물의 실제의 전기적 특성을 열잡음 모델에 적용하여, 면 위에서 측정된 간접접촉 심전도의 이론적 열잡음을 계산하였다. 이 연구를 통해, op-amp의 내부 잡음(intrinsic noise)은 저항에 의한 열잡음에 비해 무시할 수 있을 정도로 작음을 알 수 있었다. 그리고 열잡음의 크기와 능동 전극의 입력 저항간의 관계를 도출할 수 있게 되어, 능동 전극의 입력 저항의 최적 값 선정을 위한 향후 연구의 기반이 되었다.

이중 주파수 전원의 용량성 결합 플라즈마 식각장비에서 전극하전에 의한 입사이온 에너지분포 변화연구 (Electrode Charging Effect on Ion Energy Distribution of Dual-Frequency Driven Capacitively Coupled Plasma Etcher)

  • 최명선;장윤창;이석환;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제13권3호
    • /
    • pp.39-43
    • /
    • 2014
  • The effect of electrode charging on the ion energy distribution (IED) was investigated in the dual-frequency capacitively coupled plasma source which was powered of 100 MHz RF at the top electrode and 400 kHz bias on the bottom electrode. The charging property was analyzed with the distortion of the measured current and voltage waveforms. The capacitance and the resistance of electrode sheath can change the property of ion and electron charging on the electrode so it is sensitive to the plasma density which is controlled by the main power. The ion energy distribution was estimated by equivalent circuit model, being compared with the measured distribution obtained from the ion energy analyzer. Results show that the low frequency bias power changes effectively the low energy population of ion in the energy distribution.

Numerical Modeling of Floating Electrodes in a Plasma Processing System

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제24권4호
    • /
    • pp.102-110
    • /
    • 2015
  • Fluid model based numerical analysis is done to simulate a plasma processing system with electrodes at floating potential. $V_f$ is a function of electron temperature, electron mass and ion mass. Commercial plasma fluid simulation softwares do not provide options for floating electrode boundary value condition. We developed a user subroutine in CFD-ACE+ and compared four different cases: grounded, dielectric, zero normal electric field and floating electric potential for a 2D-CCP (capacitively coupled plasma) with a ring electrode.

Capacitively Coupled Plasma Source를 이용한 Etcher의 상부 전극 온도 변화에 따른 Etch 특성 변화 개선 (Improvement of Repeatability during Dielectric Etching by Controlling Upper Electrode Temperature)

  • 신한수;노용한;이내응
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.322-326
    • /
    • 2011
  • 상부 전극에 RF power 가 직접 인가되는 capacitively coupled plasma source를 이용한 oxide layer etching 공정은 현재 반도체 제조 공정에서 매우 유용하게 사용되고 있는 방식이다. 그러나 디바이스의 사이즈가 점점 작아지면서 공정을 진행하기 위한 RF power도 커지고, plasma ignition 되는 electrode 사이의 간격도 점점 좁아지는 기술적 변화가 이루어지고 있다. 이러한 H/W의 변화에 따라 예상치 못한 문제들로 공정을 적용하는데 많은 문제점이 발생하고 있는데, 공정 진행 시에 plasma의 영향으로 인한 electrode의 온도 변화도 그 중 하나이다. 이러한 온도 변화로 인해 wafer to wafer의 공정 진행 결과가 서로 다르게 나타나게 하는 문제가 야기되고 있다. 아래의 내용에서는 상부 electrode의 온도 변화에 따른 etch 특성을 연구하고, 이를 개선할 수 있는 방법에 대해 논하고자 한다.

2차원 동역학 시뮬레이션을 활용한 부분적으로 자화된 용량성 결합 플라즈마 전산 모사 (2D Kinetic Simulation of Partially Magnetized Capacitively Coupled Plasma Sources)

  • 손성현;박준범;정경재
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.118-123
    • /
    • 2023
  • Partially magnetized capacitively coupled plasma (CCP) sources are investigated using a two-dimensional kinetic simulation code named EDIPIC-2D. A converging numerical solution was obtained for CCP with a 60 MHz power source, while properly capturing the dynamics of electrons and power absorption over a single RF period. The effects of magnetic fields with different orientations were evaluated. Axial magnetic fields caused changes in the spatial distribution of plasma density, affecting the loss channel. Transverse magnetic fields enhanced stochastic heating near the powered electrode, leading to an increase in plasma density while the significant E×B drift loss compensated for this rise.

  • PDF

Simulation of Capacitively Coupled RF Plasma; Effect of Secondary Electron Emission - Formation of Electron Shock Wave

  • Park, Seung-Kyu;Kim, Heon-Chang
    • 반도체디스플레이기술학회지
    • /
    • 제8권3호
    • /
    • pp.31-37
    • /
    • 2009
  • This paper presents one and two dimensional simulation results with discontinuous features (shocks) of capacitively coupled rf plasmas. The model consists of the first two and three moments of the Boltzmann equation for the ion and electron fluids respectively, coupled to Poisson's equation for the self-consistent electric field. The local field and drift-diffusion approximations are not employed, and as a result the charged species conservation equations are hyperbolic in nature. Hyperbolic equations may develop discontinuous solutions even if their initial conditions are smooth. Indeed, in this work, secondary electron emission is shown to produce transient electron shock waves. These shocks form at the boundary between the cathodic sheath (CS) and the quasi-neutral (QN) bulk region. In the CS, the electrons emitted from the electrode are accelerated to supersonic velocities due to the large electric field. On the other hand, in the QN the electric field is not significant and electrons have small directed velocities. Therefore, at the transition between these regions, the electron fluid decelerates from a supersonic to a subsonic velocity in the direction of flow and a jump in the electron velocity develops. The presented numerical results are consistent with both experimental observations and kinetic simulations.

  • PDF

Simulations of Capacitively Coupled Plasmas Between Unequal-sized Powered and Grounded Electrodes Using One- and Two-dimensional Fluid Models

  • So, Soon-Youl
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.220-229
    • /
    • 2004
  • We have examined a technique of one-dimensional (1D) fluid modeling for radio-frequency Ar capacitively coupled plasmas (CCP) between unequal-sized powered and grounded electrodes. In order to simulate a practical CCP reactor configuration with a grounded side wall by the 1D model, it has been assumed that the discharge space has a conic frustum shape; the grounded electrode is larger than the powered one and the discharge space expands with the distance from the powered electrode. In this paper, we focus on how much a 1D model can approximate a 2D model and evaluate their comparisons. The plasma density calculated by the 1D model has been compared with that by a two-dimensional (2D) fluid model, and a qualitative agreement between them has been obtained. In addition, 1D and 2D calculation results for another reactor configuration with equal-sized electrodes have also been presented together for comparison. In the discussion, four CCP models, which are 1D and 2D models with symmetric and asymmetric geometries, are compared with each other and the DC self-bias voltage has been focused on as a characteristic property that reflects the unequal electrode surface areas. Reactor configuration and experimental parameters, which the self-bias depends on, have been investigated to develop the ID modeling for reactor geometry with unequal-sized electrodes.

Monitoring Ion Energy Distribution in Capacitively Coupled Plasmas Using Non-invasive Radio-Frequency Voltage Measurements

  • Choi, Myung-Sun;Lee, Seok-Hwan;Jang, Yunchang;Ryu, Sangwon;Kim, Gon-Ho
    • Applied Science and Convergence Technology
    • /
    • 제23권6호
    • /
    • pp.357-365
    • /
    • 2014
  • A non-invasive method for ion energy distribution measurement at a RF biased surface is proposed for monitoring the property of ion bombardments in capacitively coupled plasma sources. To obtain the ion energy distribution, the measured electrode voltage is analyzed based on the circuit model which is developed with the linearized sheath capacitance on the assumption that the RF driven sheath behaves like a simple diode for a bias power whose frequency is much lower than the ion plasma frequency. The method is verified by comparing the ion energy distribution function obtained from the proposed model with the experimental result taken from the ion energy analyzer in a dual cathode capacitively coupled plasma source driven by a 100 MHz source power and a 400 kHz bias power.

Simulation of a Dually Excited Capacitively Coupled RF Plasma

  • Kim, Heon-Chang;Sul, Yong-Tae;Park, Sung-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.513-514
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combination of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self-dc bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF