• Title/Summary/Keyword: Capacitive-sensor

Search Result 329, Processing Time 0.035 seconds

A New Method for Artifact Reduction Based on Capacitive Sensor and Adaptive Filter in Oscillometric Blood Pressure Measurement (오실로메트릭 혈압 측정에서 커패시턴스 센서와 적응필터를 이용한 새로운 잡음제거방법에 관한 연구)

  • Choi, Hyun-Seok;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.239-248
    • /
    • 2008
  • In this study, a new method using a capacitive sensor and an adaptive filter was proposed to deal with artifacts contaminating an oscillation signal in oscilometric blood pressure measurement. The proposed method makes use of a variation of the capacitance between an electrode fixed to a cuff and an external object to detect artifacts caused by the external object bumping into the cuff. The proposed method utilizes the adaptive filter based on linear prediction to remove the detected artifacts. The conventional method using linear interpolation and the proposed method using the adaptive filter were applied to three types of the artifact-contaminated oscillation signals(no overlap, non-consecutive overlap, and consecutive overlap between artifacts and oscillations) to compare them in terms of the artifact reduction performance. The proposed method was more robust than the conventional method in the case of consecutive overlap between artifacts and oscillations. The proposed method could be useful for measuring blood pressure in such a noisy environment that the subject is being transported.

A Capacitive Type Humidity Sensor Using a Polyimide Film for Hermeticity Measurement of Micro Packages (마이크로 패키지의 밀폐도 측정을 위한 정전용량형 폴리이미드 습도센서)

  • Kim, Yong-Ho;Kim, Yong-Jun;Kim, Kyung-Il;Kim, Joong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.287-291
    • /
    • 2004
  • A capacitive type humidity sensor has been fabricated using a polyimide film without hydrophobic elements and its characteristics has been evaluated for hermeticity measurement of micro packages. For a highly sensitive humidity sensor, a polyimide film without hydrophobic elements has been synthesized and used instead of using a commercial one in which 7 group elements such as fluorine or chlorine are included. Sensitivity, stability and hysteresis has been performed to characterize the fabricated sensors. The sensitivity defined as normalized percent capacitance change was 0.3751%RH and hysteresis was 0.77% in the range of 10%RH to 90%RH. Maximum deviation from the average capacitance measured for 120 minutes at 50%RH was 0.25%. The proposed humidity sensor can be used for hermeticity measurement of micro packages.

A Study on Cutting Force Measurement Using a Cylindrical Capacitive Spindle Sensor (주축 변위 센서를 이용한 절삭력 측정에 관한 연구)

  • 김일해;장동영;한동철
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.17-23
    • /
    • 2002
  • A cylindrical capacitance-type spindle displacement sensor was developed and its effectiveness as a system to monitor cutting forces during hard turning was tested in this research. The sensor was installed between the face of spindle cover and the chucking element and measured pure radial motion of the spindle under the condition with presence of roundness error at measured surface. To prove the effectiveness of the developed system hard aiming tests using ceramic inserts and tool steel as workpiece were conducted. The workpiece was hardened up to 65 Rc. The variations of pure radial motion of the spindle ware measured during the cutting tests. The signals from the sensor showed the same pattern of cutting force variations from the tool dynamometer due to the progress of tool wear. As the flank wear of the ceramic tool increased both static component of cutting forces and the amount of center shift of spindle orbit increased, Results from the research showed that the developed sensor could be utilized as an effective and cheap on-line sensing device to monitor cutting conditions and tool performance in the un-manned machining center.

Design and Theoretic Analysis of 3D Tactile Sensor (3D 촉각 센서의 설계와 이론적인 해석)

  • Sim Kwee-Bo;Hwang Han-Kun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.7
    • /
    • pp.870-874
    • /
    • 2005
  • This paper presents capacitive tactile sensor that can detect normal and shear forces. This tactile sensor consists of index plate, sensing plate, and elastic dielectric layer. The calculated sensing character is based on the changes of space between two horizontal plate. Larger overlap areas and narrow space between top and bottom plate guarantees higher sensitivity. Tactile sense information can be calculated from the changes of phase of output signal. The symmetric arrangement of sensing plates makes the manufacturing process easier and guarantees the stability of the structure. In this paper, the sensor structure is designed, the mechanism of the Proposed sensor is theoretically explained, and the simulated result is presented.

The Effect of Temperature Variations and Bonding Agents on Piezoelectric Sensor Diagnostics (온도 변화에 따른 압전체 센서 자가진단법 및 접합제의 영향에 대한 실험적 고찰)

  • Jo, HyeJin;Park, Tong-il;Park, Gyuhae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.799-804
    • /
    • 2013
  • The sensor/actuator active sensor diagnostics procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is a critical component to successfully complete the structural health monitoring (SHM) process with large numbers of active sensors typically installed in a structure. The basis of this process is to track the changes in the capacitive value of piezoelectric materials, which shows up in measured admittance. Due to the temperature dependent nature of piezoelectric materials, we investigated the effects of temperature variations on sensor diagnostic process. The effect of temperature variations found to be remarkable, modifying the measured capacitive values significantly. In addition we analyzed the effect of bonding agents between a PZT patch and a host structure. This paper summarizes considerations needed to develop such sensor diagnostic processes, experimental procedures and results, and additional issues that can be used as guidelines for future investigations.

  • PDF

Asymmetric Capacitive Sensor for On-line and Real-time Partial Discharge Detection in Power Cables

  • Changhee Son;Hyewon Cheon;Hakson Lee;Daekyung Kang;Jonghoo Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.219-222
    • /
    • 2023
  • Partial discharges (PD) have long been recognized as a major contributing factor to catastrophic failures in high-power equipment. As the demand for high voltage direct current (HVDC) facilities continues to rise, the significance of on-line and real-time monitoring of PD becomes increasingly prominent. In this study, we have designed, fabricated, and characterized a highly sensitive and cost-effective PD sensor comprising a pair of copper electrodes with different arc lengths. The key advantage of our sensor is its non-invasive nature, as it can be installed at any location along the entire power cable without requiring structural modifications. In contrast, conventional PD sensors are typically limited to installation at cable terminals or insulation joint boxes, often necessitating invasive alterations. Our PD sensor demonstrates exceptional accuracy in estimating PD location, with a success rate exceeding 95% in the straight sections of the power cable and surpassing 89% in curved sections. These remarkable characteristics indicate its high potential for realtime and on-line detection of PD.

Implementation of Capacitive Passive Telemetry RF Sensor System Using RLS Estimation Algorithm (RLS 추정 알고리즘을 이용한 정전용량형 원격 RF 센서 시스템 구현)

  • Kim, Gyeong-Yeop;Yu, Dong-Guk;Lee, Jun-Tak
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.131-137
    • /
    • 2007
  • 본 연구에서는 RLS(Rescursive Least Square) 추정 알고리즘을 이용하여 정전용량형 센서를 사용한 원격 RF 센서 시스템을 구현하고자 한다. IC 칩 형태의 원격 RF 센서 시스템이 가지는 구성의 복잡성 그리고 전력소모 문제를 해결하기 위해 보다 간단한 유도결합모델이 제안된다. 원격 RF 시스템은 페이저법을 이용하여 수학적으로 모델링되며, 모델기반의 RLS 알고리즘을 적용하기위해 시스템의 파라메타를 재배열한다. 오차 제곱합의 수렴특성을 가진 RLS 알고리즘을 이용하여 정전용량 파라메타를 추정한다. 실제 위상차를 측정하기 위해 Exclusive OR를 이용한 위상차 감지 장치를 제안한다. 센서로는 각종 환경 측정-습도, 압력 등-에 실제 활용되고 있는 정전용량형 센서를 채택한다. 잡음을 내포한 측정 데이터에 대한 추정 성능을 확인함으로써 그 유효성을 검증하고자 한다.

  • PDF

A Porous Silicon-Based Capacitive Humidity Sensor (다공질 실리콘 산화막을 이용한 용량형 습도 센서)

  • Min, Nam-Ki;Chin, Min-Suk;Ahn, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1209-1212
    • /
    • 1995
  • This paper presents a capacitive humidity sensor using porous silicon layers formed tom the anodization of p-type silicon in HF solution. The upper electrodes consist of many aluminum strips over porous silicon, between which the porous silicon is etched away. The sensor showed a good sensitivity(20pF/%RH) and lineaity in the range of 40%RH$\sim$80%RH, a hysteresis of ${\pm}2%$ RH, and a slow transient response. These preliminary resluts show that futher improvement can still be expected.

  • PDF

A Study on the On-machine Profile Measurement of Large Aspheric Form using Capasitive Sensor (정전용량센서를 이용한 대구경 비구면 형상의 기상측정에 관한 연구)

  • Kim, Geon-Hee;Won, Jonh-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.3
    • /
    • pp.56-61
    • /
    • 2003
  • This paper described about on-machine profile measurement of aspheric surfaces using contact probing technique in ultra precision machine. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime using a circle leaf spring mechanism and a capacitive-type sensor. The contact probe which is installed on the z-axis is In touch with the aspheric objects which is fixed on the spindle of the diamond turning machine(DTM) during the measuring procedure. The x, z-axis motions of the machine are monitored by a set of two orthogonal plane mirror type laser interferometers. As a results, the developed contact probe on-machine measurement system showed 10 nanometers repeatability with a ${\pm}2{\sigma}$ and uncertainty of 200 nmPv.

  • PDF