• Title/Summary/Keyword: Capacitive heating

Search Result 24, Processing Time 0.028 seconds

Development and Thermal Distribution of An RF Capacitive Heating Device (유전가열장치의 개발과 온열분포)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh, John-Kyu;Kim, Byung-Soo
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.49-58
    • /
    • 1987
  • Hypertermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to treat malignant tumors has been well established and encouraging clinical results have been obserbed. Unfortunately, however, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We developed the radiofrequency capactive hyperthermia device (Greenytherm-GY8) in cooperation with Yonsei Cancer Center and Green Cross Medical Corporation. It was composed with $8{\sim}10MHz$ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control PC computer. The thermal profile was investigated in agar phantom, animals and in human tumors, heated with capactivie RF device. Deep and homogeneous heating could be achieved in a large phantom of 25cm diameter and 19cm thick when heated with a pair of 23cm diameter electrodes, coupled to both bases of the phantom, when the size of the two electrodes was not the same, the region near the smaller electrode was preferentially heated. It was, therefore, possible to control the depth of heating by choosing proper size of electrodes. Therapeutic temperature $(42^{\circ}C{\sim}43^{\circ}C)$ could be obtained in the living animal experiments. Indications are that deep heating of humn tumors might be achieved with the capacitive method, provided that subcutaenous fat layer is cooled by temperature controlled bolus and large size of electrodes.

  • PDF

Unusual Angular Arrangement of Electrodes in Capacitive Heating Device -Thermal Distribution and Clinical Application- (유전 가열장치에서 전극의 각도 배열 -온도 분포의 특성 및 임상 적용-)

  • Seong, Jin-Sil;Chu, Sung-Sil;Kim, Gwi-Eon;John, Juhn-Kyu;Yang, Sung-Wha
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.313-320
    • /
    • 1989
  • In capacitive heating device, which considered efficient for deep heating, parallel arrangement of the electrodes is a serious limiting factor in heating for eccentrically located lesions because it causes overheating of the exposed ipsilateral skin surface, the heating pattern is also frequently inappropriate, and the arrangement tends to be unstable due to the patient's gravity. Therefore we attempted an angular arrangement of the electordes to achieve more homogenous and efficient heating for such lesions. In phantom study, both the thermal profile and thermogram established the heating pattern in this unusual angular arrangement of the electrodes at $60^{\circ},\;90^{\circ}\; and\;120^{\circ}$ angles, respectively. An angular arrangement was also clinically applied to 3 patients. The patients' tolerance was good without significant complication and the thermal distribution was satisfactory. In conclusion, this unusual arrangement of electrodes appears to be promising in the clinical application to the eccentrically located lesions.

  • PDF

Activated Carbon-Nickel (II) Oxide Electrodes for Capacitive Deionization Process

  • Gandionco, Karl Adrian;Kim, Jin Won;Ocon, Joey D.;Lee, Jaeyoung
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2020
  • Activated carbon-nickel (II) oxide (AC-NiO) electrodes were studied as materials for the capacitive deionization (CDI) of aqueous sodium chloride solution. AC-NiO electrodes were fabricated through physical mixing and low-temperature heating of precursor materials. The amount of NiO in the electrodes was varied and its effect on the deionization performance was investigated using a single-pass mode CDI setup. The pure activated carbon electrode showed the highest specific surface area among the electrodes. However, the AC-NiO electrode with approximately 10 and 20% of NiO displayed better deionization performance. The addition of a dielectric material like NiO to the carbon material resulted in the enhancement of the electric field, which eventually led to an improved deionization performance. Among all as-prepared electrodes, the AC-NiO electrode with approximately 10% of NiO gave the highest salt adsorption capacity and charge efficiency, which are equal to 7.46 mg/g and 90.1%, respectively. This finding can be attributed to the optimum enhancement of the physical and chemical characteristics of the electrode brought by the addition of the appropriate amount of NiO.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

Thermal Distribution in a Phantom Using 8MHz RF Capacitive Type Hyperthermia (8 MHz 고주파 유전형 가열장치로 가열한 모형에서의 열분포)

  • Lee Jong Young;Park Kyung Ran;Kim Kye Jun;Sung Ki Joon
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.171-176
    • /
    • 1991
  • To evaluate the temperature distribution according to the size of the electorde and the thickness of the phantom using 8MHz radiofrequency capacitive heating device, various sized electrodes and phantoms were used in combination. The radii of the electrodes are 10, 15, 20, 25, and 30 cm and the thickness of cylindrical phantoms with diameter 30 cm were 10, 15, 20, 25, 30, and 35 cm. When the thickness of the phantom was 25 cm or 30 cm, homogenous heating was achieved by using the electrode which diameter was equal to or greater than the thickness of the phantom. When the thickness of the phantom was 20 cm or less. homogenous heating was not achieved by using the electrode which diameter was equal to the thickness of the phantom, but achieved by the larger diameter of the electorode. When the sizes of paired electrodes were not equal, the smaller electrode side was preferentially heated.

  • PDF

직류 전류 이용 종양세포의 효율적 치료에 관한 시뮬레이션 연구

  • Kim, Jae-Hong;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.289-289
    • /
    • 2010
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 암세포가 사멸되는 임계온도 보다 높게 악성조직에 열을 가하는 방법이 연구되어지고 있다 [1]. 전류가 흐를 수 있는 4개의 전기탐침을 종양조직에 삽입하여 국부적으로 열을 발생시키는 발열요법으로 암을 치료하는 연구가 고려되고 있다. 발열요법은 1960년대에 시작하여 우리나라에서는 1985년 연세 암센터에서 capacitive type의 RF heating 또는 전자파에 의한 국소가온법과 방사선치료와 병용으로 이용되고 있다. 주로 이용되는 방법은 Radio frequency heating, Microwave heating, ultrasound heating을 들수 있다. 라디오주파수는 보통 300 MHz 이하의 주파수를 가리킨다. 본 연구에서는 교류파 대신에 직류전원에 의해 열을 발생하는 경우에 관한 연구이다. 전극에 의해 형성되는 전기장에 대한 방정식은 전도매질에서의 DC 응용모드이고, 조직 내에서의 직류 전류에 의해 발생되는 온도 분포를 모델링하는 bioheat 방정식과 연계된 문제이다. 전기장에 의해 발생되는 열의 근원은 resistive heat 또는 Joule 열이다. 본 연구에서는 교류 전류에 의한 RF heating 대신 단순한 모델의 경우로 직류 전류에 의한 열 발생에 관한 이론적 연구를 수행하였다. 종양 조직 내에 삽입된 전극에 22V를 인가하면 60초 이내에 $80^{\circ}C$까지 급속히 증가 된 후, 서서히 $90^{\circ}C$에 까지 도달한다. 4 개의 전극에 대칭적인 전위가 인가 된 경우 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하게 하여 효과적인 치료를 수행 할 수 있는 조건을 제시한다.

  • PDF

Design and implementation of RF hyperthermia system for deep-seated cancer therapy. (심재성 암치료를 위한 RF hyperthermia system의 설계 및 제작)

  • Yoo, Jae-Hyoung;Park, Mi-Gnon
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1985 no.06
    • /
    • pp.9-12
    • /
    • 1985
  • This paper covers the design and implementation process of RF hypertermia system for cancer therapy. Among many hyperthermic methods, RF capacitive heating method is discussed because it can heat the deep-seated tumors selectively. The RF power oscillator and its applicators were designed and implemented. And the experiments were performed with agar phantom and dog to prove that the system can heat any depth selectively. And the electrical safety and appropriateness of clinical application was proved through the human living-body test.

  • PDF

Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter (듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기)

  • Lee, Sang-Wook;Ryu, Yeoi-Joung;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

A study on a dielectric heating system for amplifying the resonant gain using the capacitance of electrodes (전극의 용량성분을 이용한 공진이득 증폭형 유전가열장치에 관한 연구)

  • Kim, Shin-Hyo;Lee, Chang-Woo;Bae, Han-Nah;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.940-946
    • /
    • 2015
  • In this paper, we study a method that amplifies the output gain of a high voltage pulse using 300 kHz or higher frequency. We conducted a study on a method for amplifying the output gain using the resonance between the capacitance components of the load and the parasitic components of the circuit, instead of the conservative method for amplifying the pulse-amplitude by raising the voltage of the power stage. In particular, the method simplifies the circuit configuration throughout the appliance of flyback-type topology instead of the bridge-type. There are advantages that prevent damage from overload and the heat in the output circuit through the hard switching by amplifying the gain of the output voltage applying to the load as given by the capacitance component of the output electrode to the output pulse waveform. This study proposed a method to enhance the spatial and electrical efficiency of the contact-type heating device through the dielectric heating method applied to the field of medical and industrial heating.