• Title/Summary/Keyword: Capacitance type

Search Result 457, Processing Time 0.027 seconds

The Design and Performance Verification of Collocated Capacitance Sensor for Magnetic Bearing (자기베어링과 공위한 축전센서의 설계 및 성능 평가)

  • 유선중;신동원;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.317-322
    • /
    • 1994
  • The design and performance verification of collocated capacitance sensor system for magnetic bearing is presented. Noncollocation between actuators and sensors may cause unstable rotor behavior. The capacitance sensor is not affected by magnetic field. PCB type capacitance sensor is installed between magnetic bearing polse. so, collocation of sensors and actuators can be achieved. Experiment of sensor's static and dynamic charactistics is conducted. Modeling of the rotor system supported by magnetic bearing is made. And performance comparison between simulation and experiment is showed.

  • PDF

Improvement of Sensitivity in Porous Silicon Alcohol Gas Sensors by UV Light (자외선조사에 의한 다공질 실리콘 알코올 센서의 감도 개선)

  • Kim, Seong-Jin;Choe, Bok-Gil
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.676-680
    • /
    • 1999
  • To do breath alcohol measurement, a sensor is necessary that it can detect low alcohol gas concentration of 0.01% at least. In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to measure low alcohol gas concentration. The sensor using porous silicon layer has some sensitivity at room temperature by very large effective surface area, but there is still much room for improvement. In this experiment, we measured the capacitance of the sensor under 254 nm UV light on the porous silicon layer, in which alcohol solution was kept in a flask at 25, 35, and $45^{\circ}C$ by a heater. As the result, the improvement of sensitivity by illuminating UV light was observed. The increasing rate of the capacitance was shown to be double more than those measured under UV-off state. It is supposed that UV light activates response of the oriental and interfacial polarizations which have slow relaxation time for AC field.

  • PDF

Development of a Capacitance-type wave Recorder for Measuring Real-Time Wave Height Based on Microprocessor Technique (마이크로프로세서 기술에 기초한 실시간 파고 계측용 용량식 파고계의 개발)

  • 김제윤;김환성;김상봉
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.162-167
    • /
    • 1996
  • This paper deals with an implementation method for the one chip microprocessor(8097)-based capacitance type wave recorder for a measuring real-time wave height. The system was developed to make it possible to real-time remote sensing the wave height by deploying the RS-232/422/485 communication methods. The system test results for the developed system such as linearity, system stability and robustness of the disturbance was also verified through the performance tests of the system. Furthermore, the system was developed after due consideration with connecting the public network such as satellite mobile communication system and LAN, through the deploying VLSI(Very Large Scale Integration) design techniques.

  • PDF

Development of Capacitance-type Humidity Sensors Using Porous Silicon Layer (다공질 실리콘층을 이용한 정전용량형 습도센서의 개발)

  • Kim, Seong-Jeen;Lee, Ju-Hyuk;Yoon, Yeo-Kyung;Choi, Bok-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1014-1016
    • /
    • 1998
  • A capacitance-type humidity sensor using porous silicon layer is developed. The unique property of this sensor is a structure which has electrodes on the surface of the wafer like a general IC device. To do this. the sensor was fabricated using process such as localized formation of porous silicon, oxidation of porous silicon layer, and etching of oxidized porous silicon layer. The measurement of humidity-sensing ability was done for two type of sensors using porous silicon layer formed in 25 and 35% HF solutions, respectively. As the result, the former sensors showed larger value and variation of capacitance for the relative humidity.

  • PDF

Capacitance properties of DLPC LB films with MLS structure fabricated by moving wall type method (Moving wall형 LB법으로 제작된 MLS DLPC LB 박막의 제작과 캐패시턴스 특성)

  • Lee, Woo-Sun;Chung, Yong-Ho;Son, Kyeong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1297-1299
    • /
    • 1998
  • LB layers of L-$\alpha$-DLPC deposited by LB method were deposited onto n-type silicon wafer as Z-type film. Films made up of 8, 16 layers of lipid with long alkyl chain and the thickness of monolayer and multilayers was determined by ellipsometry. It was deposited Ag and Al onto LB layers and silicon wafer for electrode and small electrode exhibit high capacitance and low leakage current. The C-V curves of the MLS capacitor shows very high saturation value of capacitance. And cross-sectional SEM image of MLS capacitor indicated the presence of pore with Al electrode and we found that the Ag is good for electrode metal.

  • PDF

A Study on the Changes of Meridians Potential Induced by the Manual art during Acupuncture Therapy (수기자극에 의해 유발되는 경락전위변화에 관한 연구)

  • Lee Yong-Heum;Lee Qyoon-Jung;Kim Han-Sung;Shin Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1625-1632
    • /
    • 2006
  • We studied the effects or electric potential in ST37(+) and ST39(-) generated by various the manual art stimulus or acupuncture at ST36. And compared with data on the change of electric potential from hand of performer acupuncture therapy. Electric potential induced via acupuncture from performer may be important factor that is the initiation of electric potential changes in meridian and meridian point of being performer. The results for various manual art stimulus in acupuncture therapy was that four type of electro-wave observed. That is the capacitance currents type, sign wave type, triangle wave type and circle type triangle wave. And the change of electric potential ransfer from performer acupuncture therapy in stable electro-circle condition, were capacitance currents type. So we suggested that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between performer acupuncture therapy and being performer acupuncture therapy.

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

Experimental Investigation of Parametric Effects on the Void Fraction Measurement and Flow Regime Characterization by Capacitance Transducers -Part I : Stationary Test- (캐패시턴스 변환기를 이용한 기포율 측정과 유동영역결정에 미치는 각종변수의 영향에 관한 실험적연구 -제1부 : 적정실험결과-)

  • Moon-Hyun Chun;Chang-Kyung Sung
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.34-44
    • /
    • 1985
  • The main purpose of this work is to study the effects of (1) configuration, size, and materials of electrodes, (2) flow pattern, (3) electrode position with respect to a dielectric boundary on the void fraction measurement and flow regime characterization by capacitance transducers. From the experimental results, relationships between the measured relative capacitance and void fraction are obtained for both annular and stratified flow systems under static condition, and this result is compared with theoretical predictions. From this study it can be concluded that (1) the strip-type electrodes are more sensitive than ring-type electrodes for both annular and stratified flows, (2) electrode size does not affect the relative capacitance vs. (1-$\alpha$) curve, and (3) electrode position is important for stratified flows but it has no effect on annular flows.

  • PDF

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor (정전용량 수분센서의 배지 함수량 정량화)

  • Baek, Jeong-Hyeon;Park, Ju-Sung;Lee, Ho-Jin;An, Jin-Hee;Choi, Eun-Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.27-36
    • /
    • 2021
  • A capacitive water sensor was developed to measure the capacitance over a wide part of a substrate using an insulated electrode plate (30 cm × 10 cm) with copper and Teflon attached on either side of the substrate. This study aimed to convert the capacitance output obtained from the condenser-type capacitance sensor into the substrate water content. The quantification experiment was performed by measuring the changes in substrate water weight and capacitance while providing a nutrient solution and by subsequently comparing these values. The substrate water weight and capacitance were measured every 20 to 30 seconds using the sensor and load cell with a software developed specifically for this study. Using a curve-fitting program, the substrate water content was estimated from the output of the capacitance using the water weight and capacitance of the substrate as variables. When the amount of water supplied was increased, the capacitance tended to increase. Coefficient of variation (CV) in capacitance according to the water weight in substrate was greater with the 1.0 kg of water weight, compared with other weights. Thus, the fitting was performed with higher than 1.0 kg, from 1.7 to 6.0 kg of water weight. The correlation coefficient between the capacitance and water weight in substrate was 0.9696. The calibration equation estimated water content from the capacitance, and it was compared with the substrate water weight measured by the load cell.