• 제목/요약/키워드: CapSim

검색결과 83건 처리시간 0.249초

Effect of Storage Temperature and Humidity on Water Vapor Permeability of Al-foil Laminate Paper (저장온도(貯藏溫度) 및 습도(濕度)가 알루미늄박(箔) 적층지(積層紙)의 수분투과율(水分透過率)에 미치는 영향(影響))

  • Park, Kil-Dong;Choi, Jin-Ho;Sung, Hyun-Soon;Hong, Soon-Keun
    • Korean Journal of Food Science and Technology
    • /
    • 제13권4호
    • /
    • pp.314-318
    • /
    • 1981
  • In order to improve the storage stability of spray and freeze dried red ginseng extract powder packed in a bottle, the water vapor permeability of Al-foil laminate paper used for cap closure and shelf life of those products on various storage temperatures and relative humidities were investigated. The thickness of the laminate paper was $93{\pm}3\:{\mu}m$ and its physical properties were equal to standard of ASTM (B-377-66) The absorption rate of the freeze dried powder was 2-6 times greater than that of the spray dried powder at $37^{\circ}C$. Therefore it was considered that the laminate could be used for cap closures for the spray dried powder but unsuitable for the freeze dried powder. The shelf life of the spray dried powder was longer than that of the freeze-dried powder at $37^{\circ}C$.

  • PDF

Fine Structure of Mature Sperms of Cephalopods (Octopus minor, Octopus ocellatus and Todarodes pacificus) Inhabiting the Korean Waters II (한국 연근해산 두족류 (Octopus minor, Octopus ocellatus and Todarodes pacificus) 성숙정자의 미세구조 II)

  • Kim, Sang-Won;Chang, Nam-Sub
    • Applied Microscopy
    • /
    • 제31권4호
    • /
    • pp.333-345
    • /
    • 2001
  • The mature sperms of three species of cephalopods (Octopus minar, Octopus ocellatus, Todarodes pacificus) were observed by electron microscopy. The results obtained are as follows: The sperm lengths of Octopus minor and Octopus ocellatus of octopods are long and they are about $390{\mu}m$ and $125\sim130{\mu}m$, respectively, but the sperm length of Todarodes pacificus is short and about $35{\mu}m$. The sperm of Octopus minor has a helical acrosome and a head bent a little like a banana while Octopus ocellatus of octopod has a twisted acrosome and a long rod-shaped head. A number of horizontal stripes are observed as a periodic structure in their subacrosome cavities and dense plugs are formed in the cavities of their heads. On the other hand, the acrosome of Todarodes pacificus is circular cap-shaped, and its head is long and oval. It is notable that two small cavities were observed in its basal acrosome. Juxtanuclear acrosomal materials of high electron density filled the subacrosomal cavity. In the middle piece of mature sperms of Octopus minor and Octopus ocellatus, the mitochondria form the mitochondrial sleeve, but the numbers of mitochondria differ between the species so that they are $11\sim12$ and $8\sim9$, respectively. Meanwhile, in the middle piece of mature sperms of Todarodes pacificus, the mitochondria are separated from the axoneme, forming a mitochondrial spur in which $10\sim13$ mitochondria and some electron dense materials concentrate. The axoneme of Octopus minor, Octopus ocellatus and Todarodes pacificus are of 9+2 type in common, surrounded by 9 coarse fibres. A number of glycogen were observed only in the axoneme of Todarodes pacificus. The coarse fibres were found as far as the main piece of sperm tail in Octopks minor and Todarodes pacificus, while to the end piece of sperm tail in Octopus ocellatus.

  • PDF

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • 제33권4호
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Estimation of Pollution Sources of Oenam Watershed in Juam Lake using Nitrogen Concentration and Isotope Analysis (주암호 외남천 유역 하천수의 질소농도와 동위원소비 분석을 이용한 오염원 평가)

  • Choi, Yujin;Jung, Jaewoon;Choi, Woojung;Yoon, Kwangsik;Choi, Dongho;Lim, Sangsun;Jeong, Juhong;Lim, Byungjin;Chang, Namik
    • Journal of Korean Society on Water Environment
    • /
    • 제27권4호
    • /
    • pp.467-474
    • /
    • 2011
  • In an effort to investigate water pollution characteristics of Juam lake, water samples were collected from three sites (Sites A, B, and C) of Oenam stream which is a typical tributary of rural watershed in the lake and analyzed for N concentration and the corresponding isotope ratio (${\delta}^{15}N$) of ${NO_3}^-$. Concentrations of ${NO_3}^-$ were not dramatically different among the sites; $0.8{\pm}0.2mgNL^{-1}$ (range: $0.0{\sim}4.3mgNL^{-1}$) for Site A, $1.1{\pm}0.2mgNL^{-1}$ ($0.0{\sim}4.3mgNL^{-1}$) for Site B, and $1.1{\pm}0.1mgNL^{-1}$ ($0.1{\sim}2.6mgNL^{-1}$) for Site C. Meanwhile, ${\delta}^{15}N$ tended to decrease with river flow; it was highest for Site A ($45.5{\pm}5.3$‰) followed by Site B ($19.7{\pm}2.0$‰) and Site C ($8.7{\pm}1.5$‰). Such high ${\delta}^{15}N$ values of ${NO_3}^-$ in Site A suggested that ${NO_3}^-$ derived from livestock feedlot (specifically livestock excrete of which ${\delta}^{15}N$ is higher than 10‰) is the predominant pollution sources despite mountainous area occupied the most of land-use in the watershed. Using the two-sources isotope mixing model, it was estimated that the contribution of cropping activities (i.e. fertilization) became greater in down-stream area (Sites B and C) due to the higher agricultural land-use than the up-stream area (Site A). Particularly, during the active cropping season, the low contribution of organic pollution sources indicated that domestic sewage was not the predominant pollution source. Therefore, it was suggested that agricultural sources such as livestock farming and cropping rather than mountainous and residential are the dominant sources of water pollution in the study area. These results could be effectively utilized in elucidating water pollution sources in rural areas and selecting water management practices.

A Small Monopole Antenna with Novel Impedance Matching Structure (새로운 임피던스 매칭 구조를 가지는 소형 모노폴 안테나)

  • Kim, Dong-Jin;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제18권7호
    • /
    • pp.828-833
    • /
    • 2007
  • A small monopole antenna with a novel impedance matching structure is proposed in this paper. The proposed antenna is designed for W-LAN(IEEE 802.11b). The antenna design concept is based on a ${\lambda}/8$ folded monopole antenna with a self-impedance matching structure. The size of the proposed antenna is smaller than the resonant length, thus the impedance at the terminal of the antenna becomes very capacitive. To compensate fur this impedance mismatching, the proposed antenna employs a novel self-impedance matching structure. The self-impedance matching structure is located on the top of the antenna; it improves the impedance matching and ultimately the efficiency of the antenna. The measured results of the proposed antenna show reasonable agreement with prediction.

Impact on Quality of Life of Single-parent Female Head of Household Economic Stress (한부모여성가구주의 경제적 스트레스가 삶의 질에 미치는 영향)

  • Lee, Hyun-Sim;Han, Kyu-Chul;Jeon, Gi-Bog
    • The Journal of the Korea Contents Association
    • /
    • 제13권3호
    • /
    • pp.174-183
    • /
    • 2013
  • This study in the lives of single-parent female households demographic and economic variables and economic stress quality financial satisfaction and physical health status and psychological distressed affect were analyzed. The study took advantage of an analysis of a sample of 430 people living in care facilities nationwide cap material. Using SAS 9.1 (Statistical Analysis System) were analyzed by the research model to set a single-parent female head of household demographic and economic characteristics, economic satisfaction, physical health status, was found to have a negative effect on the quality of life psychologically distressed. Also was identified as a single-parent female households experience economic stress have a negative effect on their quality of life. Especially, showed the biggest influence on the psychologically distressed was a significant influence financial satisfaction and physical health status in.

Fruit Fly Optimization based EEG Channel Selection Method for BCI (BCI 시스템을 위한 Fruit Fly Optimization 알고리즘 기반 최적의 EEG 채널 선택 기법)

  • Yu, Xin-Yang;Yu, Je-Hun;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제22권3호
    • /
    • pp.199-203
    • /
    • 2016
  • A brain-computer interface or BCI provides an alternative method for acting on the world. Brain signals can be recorded from the electrical activity along the scalp using an electrode cap. By analyzing the EEG, it is possible to determine whether a person is thinking about his/her hand or foot movement and this information can be transferred to a machine and then translated into commands. However, we do not know which information relates to motor imagery and which channel is good for extracting features. A general approach is to use all electronic channels to analyze the EEG signals, but this causes many problems, such as overfitting and problems removing noisy and artificial signals. To overcome these problems, in this paper we used a new optimization method called the Fruit Fly optimization algorithm (FOA) to select the best channels and then combine them with CSP method to extract features to improve the classification accuracy by linear discriminant analysis. We also used particle swarm optimization (PSO) and a genetic algorithm (GA) to select the optimal EEG channel and compared the performance with that of the FOA algorithm. The results show that for some subjects, the FOA algorithm is a better method for selecting the optimal EEG channel in a short time.

Impact of Central Line Insertion Bundle on the Adherence of Bundle and Central Line-Associated Bloodstream Infections in the Operating Room (수술실에서 중심정맥관 삽입 시 번들적용이 중심정맥관 관련 혈류감염에 미치는 영향)

  • Shin, Eun Jeong;Jeong, Jae Sim;Choi, Sang Ho;Huh, In Young
    • Journal of Korean Biological Nursing Science
    • /
    • 제18권4호
    • /
    • pp.257-263
    • /
    • 2016
  • Background: This study purposed to examine how the incidence of the central line-associated bloodstream infection (CLABSI) in a operating room (OR) is affected by bundle application on central line insertion (CLI) practice. Methods: The study design was a pretest-posttest experimental trial. The subjects were 83 patients before the bundle application on CLI and 70 patients after. Results: The compliance(%) of bundle on CLI of among those who observed all of the five items increased from 7.2% before the intervention to 72.9% after. By items, compliance with the maximal barrier precaution was 100% for the use of a mask and cap before and after the intervention, but increased from 73.5% before the intervention to 88.6% after for the hand hygiene, from 73.5% to 88.6% for the use of a sterile gown, and from 9.6% to 75.7% for the use of a sterile large drape covering the whole body. CLABSI did not happen on CLI either before or after the application of the bundle intervention. Conclusion: Bundle application increased compliance with the use of a sterile gown and the use of a sterile large drape. However, its effect in the prevention of CLABSI was not clear probably due to the short period of intervention in a single hospital.

Development of a new brown button mushroom cultivar 'Hogam' (갈색 양송이 신품종 '호감' 육성)

  • Oh, Youn-Lee;Jang, Kab-Yeul;Kong, Won-Sik;Shin, Pyung-Gyun;Kim, Eun-Seon;Oh, Min ji;Choi, In-Geol
    • Journal of Mushroom
    • /
    • 제13권3호
    • /
    • pp.237-242
    • /
    • 2015
  • A new brown button mushroom cultivar, 'Hogam', C34 line, was made by crossing homokaryons, ASI1164-37 and ASI1175-66, selected by RAPD analysis and by cultivating three times. Mycelium of 'Hogam' on CDA (compost dextrose agar) media grew well at $25^{\circ}C$. The optimum pin-heading temperature of new variety and optimum growing temperature was $14-18^{\circ}C$. The thickness of the mature cap and stipe were thicker than a control, 'Dahyang' that developed in 2010. The color of pileus was light brown and lighter than 'Dahyang'. Days required from casing to first harvesting were three days longer than control strain, but the weight of harvested fruiting body increased by 1.35 times. 'Hogam' cultivar are expected to contribute to the diversification of domestic mushroom cultivars.

Selective Epitaxial Growth of Si and SiGe using Si-Ge-H-CI System for Self-Aligned HBT Applications (Si-Ge-H-CI 계를 이용한 자기정렬 HBT용 Si 및 SiGe 의 선택적 에피성장)

  • Kim, Sang-Hoon;Shim, Kyu-Hwan;Kang, Jin-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.182-185
    • /
    • 2002
  • 자기정렬구조의 실리콘-게르마늄 이종접합 트랜지스터에서 $f_{max}$를 높이기 위한 방안으로 베이스의 저항 값을 감소시키고자 외부 베이스에 실리콘 및 실리콘-게르마늄 박막을 저온에서 선택적으로 성장할 수 있는 방법을 연구하였다. RPCVD를 이용하여 $SiH_{2}Cl_{2}$$GeH_{4}$를 소스 가스로 하고 HCI을 첨가하여 선택성을 향상시킴으로써 $675\sim725^{\circ}C$의 저온에서도 실리콘 및 실리콘-게르마늄의 선택적 에피성장이 가능하였다. 고온 공정에 주로 이용되는 $SiH_{2}Cl_{2}$를 이용한 실리콘 증착은 $675^{\circ}C$에서 열분해가 잘 이루어지지 않고 HCl의 첨가에 의한 식각반응이 동시에 진행되어 실리콘 기판에서도 증착이 진행되지 않으나 $700^{\circ}C$ 이상에서는 HCI을 첨가한 경우에 한해서 선택성이 유지되면서 실리콘의 성장이 이루어졌다, 반면 실리콘-게르마늄막은 실리콘에 비해 열분해 온도가 낮고 GeO를 형성하여 잠입시간을 지연하는 효과가 있는 게르마늄의 특성으로 인해 선택성이나 증착속도 모두에서 유리하였으나 실리사이드 공정시에 표면으로 게르마늄이 석출되는 현상 등의 저항성분이 크게 작용하여 실리콘-게르마늄막 만으로는 외부 베이스에의 적용은 적절하지 않았다. 그러나 실리콘막을 실리콘-게르마늄막 위에 Cap 층으로 증착하거나 실리콘막 만으로 외부 베이스에 선택적으로 증착하여 베이스의 저항을 70% 가량 감소시킬 수 있었다.

  • PDF