• Title/Summary/Keyword: Canopy hood

Search Result 8, Processing Time 0.027 seconds

A Study of Local Ventilation Design on PC Programm (국소환기 설계의 전산화에 관한 연구)

  • Yoon, Myong Cho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.213-226
    • /
    • 1993
  • The purpose of this study is to computerize the design of single source for a duct work system which is essential for the improvement of working places. There are different types of hood, such as general hood, push pull hood and canopy hood. And out of these three types, general hood and canopy hood were used as subjects of this study. The software used here was Quattro Pro 123 programm, and the hardware was IBM PS/SX(type 5510-SK4 S/N 83-05164). And the results are tabulated in

    and
    . All of the hazardous factors of working places, except for physical factors, such as noise, vibration, illumination and etc, are control measurement related. In order words, workiong places that have problems with toxic gas, mist, fume, dust, odors, biological factors or wetness can be improved by means of the local ventilation design. However, the reqires very complicate processes, and in the case of canopy hood, particularly, one runs into difficulties due to frequent discrepancies generated from calculations through many processes. Recently, progress of the computer hardware technics has been dazzling, and also the software is development rapidly. As proven in the results of this study, it is good that designs for industrial ventilation systems are readily available for easy use. It is hopeful that young scholars will develop easier and quicker methods for local ventilation designs in the future.

  • PDF
  • A Numerical Study on Performance Improvement of Canopy Hood in Melting Process (용해공정의 캐노피 후드 성능 개선에 관한 수치 해석적 연구)

    • Jung, Yu-Jin;Shon, Byung-Hyun;Lee, Sang-Man;Jung, Jong-Hyeon
      • Journal of the Korea Academia-Industrial cooperation Society
      • /
      • v.14 no.3
      • /
      • pp.1519-1526
      • /
      • 2013
    • This study reviewed the capturing performance of a canopy hood used in some melting processes of a casting manufacturing factory through a site survey. In addition, this study compared and evaluated the flow field and pressure field for the plans to enhance the hazardous air pollutants collection capacity by using CFD model. The case-2(flange attached + double hood) can be improved in terms of collection performance, but is expected to increase in hood static pressure by about 70% more than the existing structure, so it was shown that its site applicability is not good. It is judged that the shape of case-3(flange attached + double cone attached) is most suitable to improve the suction efficiency. This is because a double cone is installed at the center of the opening to concentrate the flow rate on the edge of the hood and control the hume rising to the center of the hood without a static pressure rise via the slope of the cone.

    Development of Industrial Ventilation system Design Software for the Improvement of Industrial Environment (작업환경 개선을 위한 산업환기 시스템 설계 소프트웨어 개발)

    • 김태형;배병훈
      • Journal of Environmental Science International
      • /
      • v.5 no.6
      • /
      • pp.683-697
      • /
      • 1996
    • Industrial ventilation is a crucial engineering measure to protect workers from hazardous airborne contaminants. Designing a ventilation system is not an easy task. To solve this problem, many U. S. computer programs and softwares have been developed. In Korea, asoftware, called as VPMC, was developed by Korea Industrial Safety Corporation. But VPMC could not stand alone since it can be used to design not a hood, but a ventilation system. In this research, therefore, a preprocessing software was developed. It can be used to design general ventilation system, canopy hood, open surface tank hood. The program was written in Microsoft Visual Basic. In near future, this software will be incorporated into a total package software which can be used to design a whole ventilation system.

    • PDF

    기술사 마당 - 주방 후드 부스타 배기 방식

    • Jin, Nam Gi
      • Journal of the Korean Professional Engineers Association
      • /
      • v.45 no.6
      • /
      • pp.44-51
      • /
      • 2012
    • Local functional, closed the hood and exhaust are classified as open-style hood. Around the closed hood contaminants prevent the spread of contaminants. Surrounded Some pollutants (open-style hood is used in cases where the odor, vapor diffusion, and inferior) of indoor allowed to Hood expressions, which are used for kitchen, laboratory, factory canopy is typical. Contamination that occurs during cooking, kitchen ventilation barrier materials are the biggest problem, its solution by introducing fresh outside air in the kitchen troubleshoot and. Study on the kitchen exhaust airflow for my kitchen, and perform a number of each Institute and at the University of hydrodynamic analysis is investigated.

    • PDF

    A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process (PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구)

    • Park, Dong Uk
      • Journal of Korean Society of Occupational and Environmental Hygiene
      • /
      • v.3 no.1
      • /
      • pp.91-98
      • /
      • 1993
    • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

    • PDF

    Status of Welding Fume Concentration and Local exhaust Ventilation System at Welding Laboratory in Technical High School (공업고등학교 용접실습실의 용접흄 발생농도와 국소배기 실태)

    • Hwang, Sung-Hwan;Son, Bu-Soon;Jang, Bong-Ki;Park, Jong-An;Lee, Jong-Wha
      • Journal of Korean Society of Occupational and Environmental Hygiene
      • /
      • v.11 no.1
      • /
      • pp.1-8
      • /
      • 2001
    • This study was performed to evaluate a local exhaust ventilation system capability and welding fume concentration in welding laboratory at 5 technical high schools. Results of the study are as follows; 1. The personal exposure of welding fume in welding laboratory was measured. The geometric mean of 73 personal samples was $6.27mg/m^3$($3.85{\sim}9.88mg/m^3$), and 68.5% of these exceeded TLV of the Korea Ministry of Labor. 2. The geometric mean of welding fume at outside of booth was $2.27mg/m^3$($1.57{\sim}2.58mg/m^3$). All of measured concentrations were lower than TLV of the Korea Ministry of Labor. 3. Local exhaust ventilation system in welding laboratory could not remove hazardous substance effectively because of inappropriate canopy hood and absurd design. 4. The possibility of exposure risk was estimated to be high because of working point under breathing zone, misplacement of working table and insufficient supply of respiratory protector. 5. The mean values of capture velocity and transportation velocity of local exhaust ventilation system in welding laboratory were 0.38m/sec, 4.27m/sec respectively. These values were satisfied the guideline of the Korea Ministry of Labor. 6. The efficiency of performance of local ventilation system was anticipated to be decreased because of accumulated dust and alien substance on fan and duct.

    • PDF

    Exposure Characteristics of Particles during the After-treatment Processes of Aluminum Oxide Fibers and Nickel Powders (산화알루미늄 섬유와 니켈분말 후처리공정에서 입자의 노출특성)

    • Kim, Jong Bum;Kim, Kyung Hwan;Ryu, Sung Hee;Yun, Seong-Taek;Bae, Gwi-Nam
      • Journal of Korean Society of Occupational and Environmental Hygiene
      • /
      • v.26 no.2
      • /
      • pp.225-236
      • /
      • 2016
    • Objectives: Nanomaterials have been used in various fields. As use of nanoproducts is increasing, workers dealing with nanomaterials are also gradually increasing. Exposure assessments for nanomaterials have been carried out for protection of worker's health in workplace. Exposure studies were mainly focused on manufacturing processes, but these studies on after-treatment processes such as refinement, weighing, and packing were insufficient. So, we investigated exposure characteristics of particles during after-treatment processes of $Al_2O_3$ fibers and Ni powders. Methods: Mass-production of Ni powder process was carried out in enclosed capture-type canopy hood. In a developing stage, $Al_2O_3$ was handled with a local ventilation unit. Exposure characteristics of particles were investigated for $Al_2O_3$ fiber and Ni powder processes during the periods of 10:00 to 16:00, 20 May 2014 and 13:00 to 16:00, 21 May 2014, respectively. Three real-time aerosol instruments were utilized in exposure assessment. A scanning mobility particle sizer(SMPS, nanoscan, model 3910, TSI) and an optical particle counter(OPC, portable aerosol spectrometer, model 1.109, Grimm) were used to determine the particle size distribution in the size range of 10-420 nm and $0.25-32{\mu}m$, respectively. In addition, a nanoparticle aerosol monitor(NAM, model 9000, TSI) was used to measure lung-deposited nanoparticle surface area. Membrane filters(isopore membrane filter, pore size of 100 nm) were also used for air sampling for the FE-SEM(model S-5000H, Hitachi) analysis using a personal sampling pump(model GilAir Plus by 2.5 L/min, Gilian). Conclusions: For Ni powder after-treatment process, only 27% increase in particle concentration was found during the process. However, for $Al_2O_3$ fiber after-treatment process, significant exposure(1.56-3.34 times) was observed during the process.

    The Relationship of the Severity of Sleep Apnea Syndrome to the Resting Energy Expenditure and Leptin (수면무호흡증의 중증도와 안정시 에너지 대사 및 혈중 Leptin과의 관계)

    • Lee, Kwan-Ho;Shin, Kyeong-Cheol;Ahn, Jae-Hee
      • Tuberculosis and Respiratory Diseases
      • /
      • v.46 no.6
      • /
      • pp.836-845
      • /
      • 1999
    • Background : Obesity is present in the majority of adult patients with obstructive sleep apnea(OSA) and is considered to be a major risk factor for its development. A reduction in body weight has been associated with substantial improvement in the severity of apnea. However, a variety of treatment strategies for obesity have yielded limited sucess. This study was done to determine resting energy expenditure(REE) in patients with obstructive sleep apnea and the correlation between the severity of sleep apnea and REE, and to investigate whether leptin influences REE and correlated with the severity of sleep apnea in 39 patients with OSA and 45 controls matched for obesity. Method : Overnight polysomnography was performed on all subjects using standard techniques. Measurements of REE were made using a Sensormedic Vmax 229 and a canopy system. Serum leptin concentration was measured by human leptin RIA kit of LINCO Research INC. Results : REE was greater in patients with OSA compared with controls, but there was no difference between the two groups on REE%. And also there was no significant correlation between anthropometric data, polysomnographic data and REE%. Serum leptin was linearly related to body mass index(BMI), apnea index, apnea hypopnea index and lowest arterial oxygen saturation($SaO_2$) but not related to REE%. Conclusion : This study suggests the followings. Firstly patients patients with sleep apnea have a pattern of obesity characterized by energy homeostasis at an elevated body weight set-point. In order to achieve a lower body weight in these patients, it may be necessary to increase energy expenditure by increasing physical activity. Secondly leptin level was not correlated with REE, suggesting that leptin may predominantly regulate body fat by altering eating behavior rather than calorigenesis. Lastly leptin level was significantly correlated with the severity of sleep apnea. These elevated level of leptin in patients of sleep apnea may be related to the obesity, however it needs further studies to determine the relationship between the severity of sleep apnea and serum leptin.

    • PDF

    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.