• Title/Summary/Keyword: Candle

Search Result 118, Processing Time 0.021 seconds

CuO/3Al$_2$O$_3$ㆍ2SiO$_2$, 촉매담지 세라믹 캔들필터를 이용한 먼지/NOx/SOx/HCl 제거기술

  • 문수호;홍민선;이재춘;이동섭
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.133-143
    • /
    • 2004
  • Simultaneous removal technology of particulate/NOx/SOx/HCl using CuO/3Al$_2$O$_3$ㆍ2SiO$_2$catalyst impregnated ceramic candle filters is an advanced air pollution process and provides significantly to reduce hazardous gases emitted from coal-fired power plant. This process uses a high-temperature catalytic filter for integrating SOx and HCl reduction through injection an alkali sorbent (such as hydrated lime or sodium bicarbonate), NOx removal through ammonia injection and selective catalytic reduction (SCR), and particulate collection on the catalytic filter surface. The advantages of the process include : compact integration of the emission control technologies into a single component; easy handling of dry sorbent and by-product; and improved SCR catalytic life due to lowered SOx, HCl and particulate levels. CuO/3Al$_2$O$_3$ㆍ2SiO$_2$ catalyst impregnated ceramic candle filters showed a possibility of simultaneous treatment from results which have ascertained high removal efficiency at various combined gases conditions, and in pilot plant test for 3 months, NO conversion was showed 90% over.

Applicability of precoat filtration for the drinking water treatment

  • Shin, Dae-Yewn;Ko Youn;Ji, Sung-Nam;Suh, Dong-Woo;Cho, Young-Kwan;Park, Byong-hun
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.128-131
    • /
    • 2003
  • The objective of this investigation was to evaluate applicability of precoat filtration for drinking water treatment. Precoat filter used in this experiment are candle filter. Element disk of candle used in this experiment are pore size 5$\mu\textrm{m}$(W), 10$\mu\textrm{m}$(R), 20$\mu\textrm{m}$(B) and 40$\mu\textrm{m}$(Y). And diatomaceous earth are cake pore size 3.5$\mu\textrm{m}$(A), 7$\mu\textrm{m}$(B) and 17$\mu\textrm{m}$(C). Filtrate of precoat filter during 30min are R-C 11.3, B-C 10.2, W-C 8.9, Y-C 8.6, Y-B 7.1, R-A 5.4(㎥/㎡). Turbidity of the effluent can be attained under 0.1NTU with the all combination.

  • PDF

Core-Collapse Supernovae in Spiral Galaxy M74 and the Hubble Constant

  • Jang, In Sung;Lee, Myung Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.68.1-68.1
    • /
    • 2014
  • M74 is a nearby face-on spiral galaxy that hosts three core-collapse supernovae (SNe) : SN Ic 2002ap, SN II-P 2003gd, and SN II-P 2013ej. Therefore it is an ideal target to investigate the properties of the core-collapse SNe and to improve the calibration of Type II-P SNe as a standardizable candle. However, its distance is not well known. We present a new distance estimate to M74 based on the tip of the red giant branch (TRGB). From the photometry of archival F555W and F814W images taken with the Hubble Space Telescope, we derive the TRGB to be at $ITRGB=26.13{\pm}0.02$ and the distance modulus to be $30.04{\pm}0.04$ (random) ${\pm}0.12$ (systematic) (corresponding to a linear distance, $10.19{\pm}0.14{\pm}0.56Mpc$). With this result, we calibrate the standardized candle method of SNe II-P. From the absolute magnitude of SN 2003gd corrected for its expansion velocity and reddening, we derive the value of the Hubble constant, $H0=72{\pm}6{\pm}7km\;s-1\;Mpc-1$. It is in agreement with the uncertainty with the recent estimates based on the luminosity calibration of Type Ia SNe.

  • PDF

Effect of inlet structure of filtration system on the removal characteristics of iron particles by ceramic candle filters (집진장치의 유입구조에 따른 세라믹필터의 철입자 제거특성에 미치는 영향)

  • Park, Young-Ok;Jeong, Ju-Yeong;Seo, Yong-Chil
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.189-197
    • /
    • 2009
  • Wet-type particulate removal system is employed in most of ironmaking processes. These de-dusting systems require additional downstream aggregates for treatment of water and for drying of the collected slurry. Thus dried slurry can be pressed in shape of briquettes and recycled in the steelmaking process. Different from the wet-type, the dry-type particulate removal systems generate no slurry. A high-temperature, high-pressure de-dusting system with inertial inlet was developed. The target application of this system was to remove particulate matter generated from the novel ironmaking process and other steelmaking processes. In this study we conducted tests with this newly developed system to evaluate the performance of the silica-carbide (SiC) ceramic filters. In addition, for purpose of comparison, we also conducted tests with a unit which has conventional direct inlet. Fe-Particles collected from the novel ironmaking process were used in our tests as test dusts. The temperature and the pressure were kept constant at their respective values $800^{\circ}C$ and $3kg_f/cm^2$.

  • PDF

A Study on the Diatomaceous Earth Filtration of Settling Basin Effluent (정수장 침전지 유출수의 규조토 여과에 관한 연구)

  • Shin Dae-Yewn;Ji Sung-Nam;Moon Ok-Ran;Kim Ji-Yeong;Suh Dong-Woo;Cho Young-Kwan
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.410-416
    • /
    • 2004
  • The objective of this investigation was to evaluate applicability of precoat filtration that can be substituted for rapid sand filter of conventional water treatment system(CWTS). Precoat filter used in this experiment are candle filter. Element disk of candle are pore size $10{\mu}m(R),\;20{\mu}m(B)$ And diatomaceous earth are cake pore size $3.5{\mu}m$(Standard Super- Cel; A), $7{\mu}m$(Hyflo Super-Cel; B) and $17{\mu}m$(Celite 545RV; C). $2kg/m^2$ diatomaceous earth is used for precoating, it coated candle in $5{\sim}6mm$ thickness. 1. Al adsorption dosages by diatomaceous earth used in experimental we Hyflo Super-Cel 0.843mg/g, Standard Super-Cel 0.782 mg/g and Celite 545RV 0.766 mg/g. 2. Filtrate of precoat filter during 60min are R-C combination 20.7($m^3/m^2$)>B-C 18.3($m^3/m^2$)>B-B 15.0($m^3/m^2$)> R-B 12.9($m^3/m^2$)> R-A 11,093($l/m^2$). 3. Water quality of precoat filter effluent are thus. $KMnO_4$ consumption are $1.10{\sim}2.20mg/l$, removal rate are $30.9{\sim}65.6\%$. They are R-A 1.10(mg/l)(removal rate $65.6\%$). R-C(2.20 mg/l)(removal rate $30.9\%$). 4. $Al^{3+}$ are not detected with all combination, removal rate $100\%$. 5. Considering water quality and flux, continued running time of R-A combination is 7 hr. Accumulated filtrate are $74.4 m^3/m^2$, average flux is $177.2 l/m^2{\cdot}min$. And filtrate per diatomaceous earth 1g are 37.2 l. 6. R-A effluent's water quality are $KMnO_4$ Consumption 1.10(mg/l), DOC 1.161 mg/1, Al 0.0 mg/1, $UV_{254}$ 0.016/cm, Turbidity 0.1(NTU). R-A combination is suitable to precoat filtration for the settling basin effluent treatment.

Effects on Indoor Air Quality of Burning Chemicals (Scented Candles and Incense Sticks) (태우는 생활화학제품(향초와 인센스 스틱)의 사용이 실내 공기질에 미치는 영향)

  • Eun-Ah Park;Seungyeon Eo;Yerin Oh;Na-Youn Park;Myoungho Lee;Younglim Kho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.36-42
    • /
    • 2024
  • Background: The use of scented candles and incense sticks, both of which are household products that are burned for indoor deodorization and calming effects, is increasing. Fine dust has been designated as a group 1 carcinogen by the International Agency for Research on Cancer. Volatile organic compounds (VOCs) affect air pollution and can cause diseases. Objectives: This study aims to determine the effect on indoor air quality by measuring PM2.5 and VOCs generated when burning scented candles and incense sticks. Methods: Scented candles and incense sticks were selected as household products to burn. As for the target sample, top-selling products (five types of scented candles, five types of incense sticks) were purchased online. The PM2.5 concentration according to time was measured immediately next to the sample and three meters away from each other in an enclosed space using a real-time aerosol photometer. VOCs were collected as samples under the same conditions using Tenax tubes and were quantitatively analyzed by TD-GC/MS. Results: In the case of scented candles, the concentration of PM2.5 did not increase during combustion and after being extinguished by placing a cover on the candle. For the incense sticks, the concentration of PM2.5 averaged 1,901.27 ㎍/m3. After burning scented candles and incense sticks, some VOCs concentrations were increased such as ethyl acetate and BTEX (benzene, toluene, ethylbenzene, xylene). Conclusions: Therefore, when using scented candles, extinguishment by placing a cover on the candle can be expected to reduce PM2.5. It is advisable to avoid using incense sticks because PM2.5 concentration increases from the start of combustion.

A Study and Analysis for Chemical Components both Air and Total Suspended Particulates at Industrial Region (대기와 부유분진중 화학 성분의 분석에 대한 비교 연구)

  • 박원우;박흥재
    • Journal of Environmental Science International
    • /
    • v.2 no.3
    • /
    • pp.217-225
    • /
    • 1993
  • This study was performed at Sa-Sang Industrial area in Pusan City. To measure the total suspended particulates(T.S.P) and $SO_3$ following places was selected industrial area, down town, residentail area. T.S.P was collected on glass filters by High-Volume Air Sampler, $SO_3$ was measured by PbO2 Candle method. The collected T.S.P was analyzed for various anlon(for example, $NO_3$, $SO_4$, $PO_4$, F, Cl) by ion Chromatography, and Pb by Inductively Coupled Plasma.

  • PDF

Fabrication and Evaluation of Ceramic Candle Filter for Pressurized Fluidized-Bed Combustion (가압유동층 복합발전용 세라믹 캔들필터의 제조 및 성능평가)

  • 이상훈;이승원;이기성;서두원;한인섭;박석주;박영옥;우상국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.187-191
    • /
    • 2002
  • 현재 석탄의 액화 및 가스화에 관한 연구가 활발하게 이루어지고 있으며 경제성과 환경문제에 우수한 성능을 보이는 석탄가스화 복합발전 시스템(PFBC, Pressurized Fluidized-Bed Combustion)이 부각되고 있다. 가압유동층 복합발전 시스템은 약 6~10기압 및 석탄 연소열에 의한 750~90$0^{\circ}C$의 고온고압의 연소기체를 가스터빈에 사용하여 증기터빈과 함께 복합발전을 한다.(중략)

  • PDF

기고문 - 대만(臺灣)이에리우Yehliu 해변에서 본 지진 조산운동(造山運動)으로 형성된 암반(巖盤)과 그 침식작용(侵蝕作用)으로인한 특이지형 경관(景觀)의 붕괴(崩壞)과정 소고(小考)

  • Cho, Kyu-Yeong
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.51
    • /
    • pp.30-43
    • /
    • 2010
  • Yehliu is located at Wanli of Taipei Country with a long cape. Because the rock layer of nearby seashore contains limestone subject to sea erosion, weathering and earth movements, Yehliu is full of seawater-eroded holes as well as numerous rocks in the shape of mushroom, candle, ginger, and chessboard. All these make this 1,700-meter-long cape a geology park with rich ecological resources and a prosperous fishing village. It indicates how the geological features formed by the foundation orogeny and collapsed due to the marine erosion over thousands of years.

  • PDF

Isolation and Identification of Campylobacter spp. from Raw Chicken Carcasses in food Service (집단 급식용 생계 육에서 Campylobacter의 분리 및 동정)

  • 박종현
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.4
    • /
    • pp.258-263
    • /
    • 2001
  • Campylobacter spp. isolated and identified from the raw chicken carcasses in food service, were characterized. Total bacterial counts on the skins of raw chicken were 10$^4$~10$^{6}$ CFU/g and a total of 205 strains were primarily isolated after enrichment culture and selective culture of the sample with candle and microaerophilic chamber method. Among them, twenty eight strains of Gram-negative, catalase-positive and oxidase-positive were further isolated by the determination of biochemical characteristics. Only sixteen strains of them were finally identified as Campylobacter with PCR of pA and pB primers. Nine strains, more than half of them, have grown at 42$^{\circ}C$ and $25^{\circ}C$ and seven strains defined as thermophilic Campylobacter grew not at $25^{\circ}C$, but at 42$^{\circ}C$. Therefore, more careful management of food safety for raw chicken is needed in food service. Particularly, we should concern the raw chicken carcasses with high bacteria contamination, more them 10$^{5}$ CFU/g, which possibly includes Campylobacter spp. grown at low temperature.

  • PDF