• Title/Summary/Keyword: Cancer patients

Search Result 10,735, Processing Time 0.047 seconds

Identification of Genes Connected with the Sensitivity to 5-FU and Cisplatin in Squamous Cell Carcinoma Cell Lines (편평세포암 세포주에서 5-FU와 Cisplatin에의 감수성과 관련된 유전자의 동정)

  • Choi, Na-Young;Kim, Ok-Joon;Lee, Geum-Sug;Kim, Byung-Gook;Kim, Jae-Hyeong;Jang, Youn-Young;Lim, Won-Bong;Chong, Min-A;Choi, Hong-Ran
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.287-300
    • /
    • 2005
  • Squamous cell carcinoma (SCC) in head and neck show a variability in the response to chemotherapy, even when it present with similar histological tumor type, grade, and clinical stage. The purpose of present study it to identify predictive bio-marker for the sensitivity or resistance to conventional chemotherapeutic agents, 5-fluorouracil (5-FU) and Cisplatin Oral cancer cell lines were used in present study. MTT assay was performed to evaluate the sensitivity and/or resistance to 5-FU and Cisplatin. And RT-PCR was carried out for evaluation of the mRNA expressions of various genes associated with mutation, inflammation (COX pathway), cell cycle, senescence and extracellular matrix (ECM). The molecules which are correlated with the sensitivity to 5-FU are XPA, XPC, OGG, APEX, COX-2, PPAR, Cyclin E, Cyclin B1, CDC2, hTERT, hTR, TIMP-3, TIMP-4 and HSP47. And the molecules are correlated with the sensitivity to Cisplatin are COX-1, iNOS, eNOS, PCNA, collagen 1 and MMP-9. Taken together, when choosing the appropriate chemotherpeutic agents for patients, considering the molecules which are correlated or reversely correlated is helpful to choose the resonable agents for cancer patients.

A Study on the Incidence of Thyroid Cancer in Gender Ultrasound (초음파검사에서 성별에 따른 갑상샘 암의 빈도에 관한 연구)

  • Kwak, Eun-Suk;Lim, Cheong-Hwan;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.145-153
    • /
    • 2015
  • Thyroid nodules are an endocrine disease often found in clinical practice, and patients with thyroid nodules found by chance have rapidly increased alongside development of thyroid ultrasound techniques for health examination purposes. This study analyzes the subjects' general characteristics, thyroid ultrasounds, and fine needle aspiration cytology in order to find out the relationship between male and female thyroid nodules and thyroid cancer frequency. An ultrasound examination of the thyroid was performed for 32,973 individuals who visited the K Hospital of Health Examination. Subjects have no history of thyroid disease and are 20 years old or over. Data of general characteristics, diabetes) was collected by a written survey completed by the subject, and the ultrasound of the thyroid(thyroid nodules existence, size, number) and FNAC was used to find out the malignancy rate. Frequency of patients with thyroid nodule was 4,611(26.1%) in men and 5,341(34.9%) in women between 32,973 individuals. Women's prevalence rate is significantly higher than men, and the prevalence rate significantly increased with age in men and women(p < 0.05). The prevalence of multiple nodules was significantly higher in women(43.5%) than in men(35.6%), and significantly increased with age in men and women(p < 0.05). The fine needle aspiration cytology was performed in 692(men 342, women 350) subjects who showed signs of malignancy through ultrasound. Prevalence of malignancy of the nodules was higher in men(33.3%) than in women(29.4%) although it is not statistically significant. It is known that thyroid nodule prevalence in women is much higher than in men. But this study shows the men's prevalence rate was not too low compared with women, and the men showed a rather higher malignancy rate in nodules than women. It is considered that the role of thyroid ultrasound is both important in men and women.

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Long Term Follow Up Results of Serum Squamous Cell Carcinoma Antigen Level in Uterine Cervix Cancer Treated by Radiotherapy (자궁경부암 방사선치료 후 혈중 Squamous Cell Carcinoma 항원치의 장기추적 결과)

  • Yun, Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.283-290
    • /
    • 2003
  • Purpose: To evaluate the long term significance of the squamous cell carcinoma (SCC) antigen (Ag) as a tumor marker in uterine cervix carcinoma. Materials and Methods: The SCC antigen levels of pre-radiotherapy and serial post-radiotherapy serum were analyzed in 48 patients who received radiotherapy with histologically proven primary SCC of the uterine cervix. Results: Pre-radiotherapy SCC Ag level was high ($\geq$2 ng/ml) at 79.2$\%$. After the treatment, the SCC Ag level was significantly decreased. The SCC Ag level measured at about 3 months after radiotherapy was high at 23.0$\%$. In further follow up measurements, a rise of the SCC Ag to a high level was well associated with clinical relapse. The specificity of the elevated SCC Ag level in association with recurrent or persistent disease was 100$\%$, and the sensitivity was 85.7$\%$. In 3 of 4 lung metastasis cases, lung lesions were detected in chest PA before elevation of the SCC Ag level. The median lead time of the high SCC Ag level to clinical recurrence was 4 months. Conclusion: SCC Ag was a good tumor marker for monitoring treatment effect in patients with increased pre-treatment levels except in case of early lung metastasis. Elevation of the SCC Ag level after radiotherapy accurately predicted the treatment failure with lead time of 4 months. But, in early lung metastasis cases, the SCC level may be normal temporarily. Thus, chest PA should be checked to evaluate the presence of lung metastasis.

Thoracic Nodal Staging in Non-small Cell Lung Cancer by FDG-PET (비소세포폐암의 병기 판정에 있어서 N staging에서의 PET의 역할)

  • Yoo, Ji-Hoon;Kwon, Sung-Youn;Yoo, Chul-Gyu;Lee, Choon-Taek;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.290-297
    • /
    • 2000
  • Background : Current non-invasive methods for evaluating the mediastinum by computed tomographic (CT) scan have limited sensitivity and specificity. The recently introduced PET was reported to be a more sensitive and specific method for the mediastinal staging of NSCLC (sensitivity : 76-100 %, specificity : 81-100%) than CT or MRI. We assessed the usefulness of PET in the mediastinal staging of NSCLC. Methods : We reviewed the medical records of NSCLC patients that had undertaken staging work-up by both CT and PET before thoracotomy between January 1997 and December 1998. A total of 23 patients were enrolled in the study (14 males and 7 females) with a mean age of 61$\pm$9 years. By comparing the clinical(CT and PET) and pathologic stagings, we evaluated the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of PET in thoracic nodal staging. Results : Sensitivity, specificity, positive predicted value and negative predicted value were 38%, 40%, 25% and 50% respectively for computed tomography, and 50%, 60%, 30% and 69% for PET. The accuracy of FDG-PET in our study was lower than that reported by previous other studies. Conclusion : The addition of FDG-PET to CT scanning has limited benefit for the thoracic nodal staging of NSCLC, but its value in our study was lower than that observed by others.

  • PDF

RALY RNA Binding Protein-like Reduced Expression is Associated with Poor Prognosis in Clear Cell Renal Cell Carcinoma

  • Cui, Zhi-Wen;Xia, Ye;Ye, Yi-Wang;Jiang, Zhi-Mao;Wang, Ya-Dong;Wu, Jian-Ting;Sun, Liang;Zhao, Jun;Fa, Ping-Ping;Sun, Xiao-Juan;Gui, Yao-Ting;Cai, Zhi-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3403-3408
    • /
    • 2012
  • The molecular mechanisms involved in the progression of clear cell renal cell carcinomas (ccRCCs) are still unclear. The aim of this study was to analyse the relationships between expression of RALYL and clinical characteristics. In 41 paired samples of ccRCCs and adjacent normal tissues, we used real-time qPCR to evaluate the expression of RALYL mRNA. RALYL protein levels were determined in 146 samples of ccRCC and 37 adjacent normal tissues by immunohistochemistry. Statistical analysis was used to explore the relationships between expression of RALYL and the clinical characteristics (gender, age, tumor size, T stage, N stage, M stage, survival times and survival outcome) in ccRCC. In addition, these patients were follow-up period 64 months (range: 4~116months) to investigate the influence on prognosis. We found significantly differences between ccRCC tissues and normal tissues (p<0.001, paired-sample t test) in mRNA levels of RALYL. Immunohistochemistry analyses in 146 ccRCC samples and 37 adjacent normal tissues showed significantly lower RALYL protein levels in ccRCC samples (${\chi}^2$-test, p<0.001), inversely correlating with tumour size (p=0.024), T stage (0.005), N stage (p<0.001) as well as M stage (p=0.019), but not age (p=0.357) and gender (p=0.348). Kaplan-Meier survival analysis demonstrated that people with lower level of RALYL expression had a poorer survival rate than those with a higher level of RALYL expression, significantly different by the log-rank test (p=0.011). Cox regression analysis indicated that RALYL expression (p=0.039), N stage (p=0.008) and distant metastasis (p<0.001) were independent prognosis factors for the overall survival of ccRCC patients. We demonstrated that the expression of RALYL was significantly low in ccRCC and correlated with a poor prognosis in a large number of clinical samples. Our findings showed that RALYL may be a potential therapeutic target as well as a poor prognostic factor.

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Analysis of the Movement of Surgical Clips Implanted in Tumor Bed during Normal Breathing for Breast Cancer Patients (유방암 환자의 정상 호흡에서 종양에 삽입된 외과적 클립의 움직임 분석)

  • Lee, Re-Na;Chung, Eun-Ah;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Ji-Hye
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.192-200
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: To evaluate the movement of surgical clips implanted in breast tumor bed during normal breathing. $\underline{Materials\;and\;Methods}$: Seven patients receiving breast post-operative radiotherapy were selected for this study. Each patient was simulated in a common treatment position. Fluoroscopic images were recorded every 0.033 s, 30 frames per 1 second, for 10 seconds in anterior to posterior (AP), lateral, and tangential direction except one patient's images which were recorded as a rate of 15 frames per second. The movement of surgical clips was recorded and measured, thereby calculated maximal displacement of each clip in AP, lateral, tangential, and superior to inferior (SI) direction. For the comparison, we also measured the movement of diaphragm in SI direction. $\underline{Results}$: From AP direction's images, average movement of surgical clips in lateral and SI direction was $0.8{\pm}0.5\;mm$ and $0.9{\pm}0.2\;mm$ and maximal movement was 1.9 mm and 1.2 mm. Surgical clips in lateral direction's images were averagely moved $1.3{\pm}0.7\;mm$ and $1.3{\pm}0.5\;mm$ in AP and SI direction with 2.6 mm and 2.6 mm maximal movement in each direction. In tangential direction's images, average movement of surgical clips and maximal movement was $1.2{\pm}0.5\;mm$ and 2.4 mm in tangential direction and $0.9{\pm}0.4\;mm$ and 1.7 mm in SI direction. Diaphragm was averagely moved $14.0{\pm}2.4\;mm$ and 18.8 mm maximally in SI direction. $\underline{Conclusion}$: The movement of clips caused by breathing was not as significant as the movement of diaphragm. And all surgical clip movements were within 3 mm in all directions. These results suggest that for breast radiotherapy, it may not necessary to use breath-holding technique or devices to control breath.

Analysis of target volume motion followed by induced abdominal compression in tomotherapy for prostate cancer (전립선암 환자의 복부압박에 따른 표적 움직임 분석)

  • Oh, Jeong Hun;Jung, Geon A;Jung, Won Seok;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2014
  • Purpose : To evaluate the changes of the motion of abdominal cavity between interfraction and intrafraction by using abdominal compression for reducing abdominal motion. Materials and Methods : 60 MVCT images were obtained before and after tomotherapy from 10 prostate cancer patients over the whole radiotherapy period. Shift values ( X -lateral Y -longitudinal Z -vertical and Roll ) were measured and from it, the correlation of between interfraction set up change and intrafraction target motion was analyzed when applying abdominal compression. Results : The motion changes of interfraction were X-average $0.65{\pm}2.32mm$, Y-average $1.41{\pm}4.83mm$, Z-average $0.73{\pm}0.52mm$ and Roll-average $0.96{\pm}0.21mm$. The motion changes of intrafraction were X-average $0.15{\pm}0.44mm$, Y-average $0.13{\pm}0.44mm$, Z-average $0.24{\pm}0.64mm$ and Roll-average $0.1{\pm}0.9mm$. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : Abdominal compression can minimize the motion of internal organs and patients. So it is considered to be able to get more ideal dose volume without damage of normal structures from generating margin in small in producing PTV.