• Title/Summary/Keyword: Cancer metastasis

Search Result 2,584, Processing Time 0.034 seconds

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

The Role of External Irradiation for the Locally Advanced Papillary Thyroid Cancers (국소적으로 진행된 갑상선 유두암에서의 방사선치료의 역할)

  • Kim Tae-Hyun;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.187-194
    • /
    • 1999
  • Purpose : The aim of this study is to look for the possible efficacy of external irradiation for locally advanced papillary thyroid cancers (stage pT4 or Nl ). Methods and Materials : From August 1981 through September 1997, 91 Patients with locally advanced papillary thyroid cancers (stage pT4 or Nl ) have been treated with external irradiation and followed up at our clinic. All of the patients have been treated with surgical resection. After surgery, 23 patients received postoperative external irradiation with or without ablative radioiodine therapy, whereas the other 68 patients were treated with ablative radioiodine therapy alone. Distributions of sex, age, and stage were comparable in both irradiated and nonirradiated groups. Multivariate analysis of the influence by age, sex, stage, ablative radioiodine therapy and external irradiation on local control were peformed by using Cox's proportional hazard model. Results : Overall survival rates at 7 years were of no significant difference in both groups. There were $98.1\%$ for no RT group and $90\%$ for RT group (p=0.506). 5-year local control rates were significantly different, these were $95.2\%$ for RT group and $67.5\%$ for no RT group (p=0.0408). An analysis of the prognostic factors, age, sex, stage, and RAI were not significant variables, except for the external irradiation. Conclusion : Adjuvant postoperative external irradiation did not affect overall survival, but significantly improved local control in the patients with locally advanced papillary thyroid cancers (stage pT4 or lympy node involvement).

  • PDF

A Clinical Review and Results of Treatment in Non-squamous Cell Tumor of the Maxilla (상악동에 발생한 비편평세포암의 임상양상 및 치료성적)

  • Kim Se-Heon;Kim Kwang-Moon;Choi Eun-Chang;Keum Ki-Chang;Koh Yoon-Woo;Hong Won-Pyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.182-190
    • /
    • 1998
  • Background: Most of the cancers of maxillary sinus are the squamous variety, but various histopathologic types of malignant tumor can occur in the maxillary sinus. These non-squamous cell tumors have quite different patterns of clinical behavior compared with squamous variety, such as invasive characters, route of metastasis, treatment modality, and so on. Objectives: The authors intend to establish the clinical characteristics and treatment modalities of non-squamous cell tumors of the maxillary sinus. Material and Methods: We experienced 16 cases of non-squamous cell tumors arisen from the maxillary sinus during the 10-year period from 1987 to 1996. We analyzed their clinical features, therapeutic modalities and results with review of literatures. Results: According to AJCC TNM system, 13 patients presented with $T_{1-2}$, 3 with $T_{3-}4$, Two patients were treated with surgery after radiotherapy, 3 patients with surgery after chemotherapy and radiotherapy, 4 patients with chemotherapy and radiotherpy, 5 patients with chemotherapy and radiotherapy after surgery. Conclusion: In cases of adenoid cystic carcinoma, adenocarcinoma and sarcoma, we believe that the best form of therapy is wide surgical excision. If there is microscopic evidence of disease at or close to the resection margin, postoperative radiation was used to achieve better local control. In cases of undifferentiated carcinoma, preoperative chemotherapy and radiation therapy showed improved outcomes.

  • PDF

Simultaneous Elevation of Serum Parathyroid Hormone(PTH) and Parathyroid Hormone-related Protein(PTHrP) in a Case of Lung Cancer with Hypercalcemia (고칼슘혈증을 보인 폐암환자에서 부갑상선호르몬(PTH)과 부갑상선호르몬관련단백질(PTHrP)이 동시에 증가된 1예)

  • Kim, Yu-Il;Kim, Kyu-Sik;Yu, Young-Kwon;Park, Chang-Min;Rim, Myung-Soo;Ko, Kyung-Haeng;Hwang, Jun-Hwa;Park, Hyeong-Kwan;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.525-532
    • /
    • 1999
  • The parathyroid hormone related protein (PTHrP) is the most common causative peptide of humoral hypercalcemia of malignancy. In contrast, the serum level of parathyroid hormone (PTH) is low to undetectable in the majority of patients with malignancy associated hypercalcemia. Few cases exist in which the production and secretion of PTH by malignant nonparathyroid tumors have been authenticated. To our knowledge, there is very rare case in which a nonparathyroid tumor expressed simultaneously both the PTH and PTHrP. We report a case of squamous cell carcinoma of the lung with hypercalcemia which presented with simultaneous elevation of serum PTH and PTHrP. Severe hypercalcemia (serum calcium, 7.5 mEq/L) was found in a 65-year-old man who had a squamous cell carcinoma of the lung without any bony metastasis and detectable parathyroid abnormalities on isotope scintigraphy. The serum level of intact parathyroid hormone (PTH) con centration was markedly elevated as measured in two site radioimmunoreactive PTH assays (intact PTH 150 pg/mL ; normal 9~55). The serum level of a PTHrP was also increased as measured in C-terminal region specific radioimmunoassay (PTHrP 99.1 pmol/L; normal 13.8~55.3). There are no evidences of coincidental primary hyperparathyroidism in parathyroid MIBI scan and other imaging studies including neck ultrasonography and computed tomography. These results suggest that simultaneous elevation of serum PTH and PTHrP in this patient can be caused by production of both PTHrP and PTH in other nonparathyroid lesions such as squamous cell carcinoma.

  • PDF

Video-Assisted Thoracic Surgery Lobectomy: Experience with 36 Cases (비디오 흉강경을 이용한 폐엽절제술: 치험 36예)

  • Lee, Hee-Sung;Lee, Jae-Woong;Kim, Kun-Il;Cho, Sung-Woo;Park, Sang-Jun;Kim, Hyoung-Soo;Shin, Yoon-Cheol;Shin, Ho-Seung
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.732-737
    • /
    • 2009
  • Background: Many video-assisted thoracic surgery (VATS) lobectomies are performed as a potential alternative to thoracotomy despite the controversy about the safety and the associated morbidity/mortality rates. Material and Method: Between November 2006 and August 2008, we performed 87 lobectomies (VATS 36, Thoracotomy 51) and we retrospectively reviewed the surgical treatment results. A VATS lobectomy was performed by a 4~5 cm thoracotomy without rib spreading and this included anatomic hilar dissection, individual vessel and bronchus stapling and lymph node dissection. Result: We studied 52 male and 35 female patients whose age ranged from 6 to 79 (average age: $59.8{\pm}15.0$ years). The cases were diagnosed with lung cancer (66) (SQC 24, ADC 38, others 4), pulmonary metastasis (2), carcinoid (2) and benign diseases (17). There was no intraoperative death. Postoperative complications were seen in 5 (15.6%) VATS and 33 (64.7%) thoracotomies, and perioperative death caused by adult respiratory distress syndrome occurred in 1 (2.8%) VATS and 3 (5.9%) thoracotomies. Three patients Underwent conversion to thoracotomy (8.3%). The mean time to chest tube removal was 6 days for VATS and 9.4 days for thoracotomy (p<0.001), and the mean length of the hospital stay was 8 days for VATS and 12.8 days for thoracotomy (p<0.001). Conclusion: VATS lobectomy can be performed safely with low morbidity/mortality rates. Furthermore, all the patients benefited from earlier postoperative rehabilitation and less pain and they were candidates for an earlier return to normal activities.

A Prospective Randomized Comparative Clinical Trial Comparing the Efficacy between Ondansetron and Metoclopramide for Prevention of Nausea and Vomiting in Patients Undergoing Fractionated Radiotherapy to the Abdominal Region (복부 방사선치료를 받는 환자에서 발생하는 오심 및 구토에 대한 온단세트론과 메토클로프라미드의 효과 : 제 3상 전향적 무작위 비교임상시험)

  • Park Hee Chul;Suh Chang Ok;Seong Jinsil;Cho Jae Ho;Lim John Jihoon;Park Won;Song Jae Seok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.127-135
    • /
    • 2001
  • Purpose : This study is a prospective randomized clinical trial comparing the efficacy and complication of anti-emetic drugs for prevention of nausea and vomiting after radiotherapy which has moderate emetogenic potential. The aim of this study was to investigate whether the anti-emetic efficacy of ondansetron $(Zofran^{\circledR})$ 8 mg bid dose (Group O) is better than the efficacy of metoclopramide 5 mg lid dose (Group M) in patients undergoing fractionated radiotherapy to the abdominal region. Materials and Methods : Study entry was restricted to those patients who met the following eligibility criteria: histologically confirmed malignant disease; no distant metastasis; performance status of not more than ECOG grade 2; no previous chemotherapy and radiotherapy. Between March 1997 and February 1998, 60 patients enrolled in this study. All patients signed a written statement of informed consent prior to enrollment. Blinding was maintained by dosing identical number of tablets including one dose of matching placebo for Group O. The extent of nausea, appetite loss, and the number of emetic episodes were recorded everyday using diary card. The mean score of nausea, appetite loss and the mean number of emetic episodes were obtained in a weekly interval. Results : Prescription error occurred in one patient. And diary cards have not returned in 3 patients due to premature refusal of treatment. Card from one patient was excluded from the analysis because she had a history of treatment for neurosis. As a result, the analysis consisted of 55 patients. Patient characteristics and radiotherapy characteristics were similar except mean age was $52.9{\pm}11.2$ in group M, $46.5{\pm}9.5$ in group O. The difference of age was statistically significant. The mean score of nausea, appetite loss and emetic episodes in a weekly interval was higher in group M than O. In group M, the symptoms were most significant at 5th week. In a panel data analysis using mixed procedure, treatment group was only significant factor detecting the difference of weekly score for all three symptoms. Ondansetron $(Zofran^{\circledR})$ 8 mg bid dose and metoclopramide 5 mg lid dose were well tolerated without significant side effects. There were no clinically important changes In vital signs or clinical laboratory parameters with either drug. Conclusion : Concerning the fact that patients with younger age have higher emetogenic potential, there are possibilities that age difference between two treatment groups lowered the statistical power of analysis. There were significant difference favoring ondansetron group with respect to the severity of nausea, vomiting and loss of appetite. We concluded that ondansetron is more effective anti-emetic agents in the control of radiotherapy-induced nausea, vomiting, loss of appetite without significant toxicity, compared with commonly used drug, i.e., metoclopramide. However, there were patients suffering emesis despite the administration of ondansetron. The possible strategies to improve the prevention and the treatment of radiotherapy-induced emesis must be further studied.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF