• 제목/요약/키워드: Canal transportation

검색결과 61건 처리시간 0.021초

만곡근관의 확대시 기구에 따른 형태변화에 관한 연구 (TRANSPORTATION OF CURVED CANAL AFTER CANAL ENLARGEMENT ACCORDING TO FILING INSTRUMENTS)

  • 이석종;신영근;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.503-510
    • /
    • 1999
  • The purpose of this study was to evaluate the amount of transportation of original canal, zip formation, permanent deformation and fracture of instruments after canal enlargement. In this study, the 60 resin blocks that have curved canals were randomly divided into 3 experimental groups with 20 teeth each according to instrument types and filling methods for canal enlargement. The curved canals of each experimental groups were enlarged to No 40 ISO size with the K-flexo stainless steel file (Group 1), Engine-driven Ni-Ti Profile new series(Group 2) and Engine-driven Ni-Ti Quantec 2000 series(Group 3) according to the manufacturer's recommendation. Pre- and postoperative X-rays were taken at same position and the films were scanned and the canal images were traced to determine the canal curvature according to the method of Schneider. The amount of reduction in canal curvature were calculated between pre- and postoperative X-rays. In addition to zip formation, permanent deformation and fracture of instruments were examined after canal enlargement. The results were as follows : 1. All experimental groups showed some loss of canal curvature after instrumentation. There was a significant change in curvature between before and after instrumentation in each group(p<0.001). 2. Engine-driven Ni-Ti instrumentations resulted in an average loss of curvature of 2.36 degrees for Profile new series, 3.43 degrees for Quantec series, and hand instrumentation showed an average loss of curvature of 6.48 degrees for K-flexo file. There was a statistical significant difference between hand instrumentation and engine-driven Ni-Ti instrumentations(p<0.05). But there was no statistical difference between Profile new series and Quantec series. 3. There were many apical zip formations in group 1(Hand instrumentation). But there were no apical zip formations in group 2,3(Engine-driven Ni-Ti instrumentation). 4. The instrument deformation occured 9 cases in group 1(K-flexo file), 2 cases in group 2(Profile new series) and 3 cases in group 3(Quantec) after instrumentation. And the instrument fracture occured 1 case in each group. The results showed that the engine-driven Ni-Ti instruments, if we use carefully according to manufacturer's recommendations, can be use effectively for instrumenting the curved root canals in case of the MAF was over size 40.

  • PDF

레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구 (A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS)

  • 양인석;강인철;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.393-401
    • /
    • 2005
  • 본 연구는 형태 및 재질이 동일한 엔진구동형 ProTaper파일과 수동형 ProTaper파일을 이용하여 레진모형근관을 성형한 후 근관형태 변화를 비교 분석하고자 시행되었다. 본 연구에서는 레진모형근관으로 총 40개의 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다. 근관 성형 기구로는 엔진구동형 Ni-Ti 파일로 $ProTaper^{TM}$, 수동형 Ni-Ti 파일로 $ProTaper^{(R)}$ For Hand Use를 사용하였다. 사용된 레진모형근관과 파일의 종류에 따라 10개씩 4개의 그룹으로 나누어 근관성형을 시행하였다. 근관 성형 전$\cdot$후 이미지를 스캐너 (Color scanner, UMAX Technologies, Inc., USA)를 이용하여 얻은 후. Photoshop 7.0 프로그램 (Adobe System Inc., USA)을 이용하여 이미지를 중첩하였다. 이미지 분석 프로그램 (Image-$Pro^{(R)}$ Plus, Media Cybernetic, USA)을 이용하여 치근단 쪽에서부터 0, 1, 2, 3, 4, 5, 6 및 7 mm 수준에서 근관 성형에 따른 근관의 내측 및 외측 폭경의 변화량, 근관 총폭경의 변화량, 근관 중심축의 변위량을 측정하였다. 또한 근관 성형 시간을 기록하였다. 두 기구 사이의 유의성 검정을 위해 독립 표본 t-검정을 시행하여, 근관 성형 시 수동형 ProTaper 파일이 엔진구동형 ProTaper 파일에 비해 근관 중심축의 변위가 유의하게 덜 일어나며 근관의 원래 형태를 더욱 잘 유지할 수 있지만, 근관 성형시간은 길어질 수 있다는 결론을 얻었다.

LightSpeed and SimpliFil : Designed for Successful Endodontics

  • Senia, Steve
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 춘계학술대회
    • /
    • pp.259-259
    • /
    • 2001
  • ;A new root canal instrument and instrumentation technique: a preliminary report. Cleaning and shaping the root canal system has been and continues to be a challenge for even the most experienced endodontist. Curved. narrow canals. in particular. cause difficulties for the beginner as well as the specialist. A new instrument designed to incorporate new concepts was developed to ameliorate the problems in cleaning and shaping root canal systems. This new instrument has been given the name of SW (Senia and Wildey). The new SW instrument uses controlled right and left rotational forces. This motion was used to clean and shape simulated root canals in plastic blocks and root canals in extracted teeth. Instrumentation appeared to be easier. faster. and more precise than with conventional instruments. especially in curved canals where there was remarkable reduction of canal transportation. A mechanical version of the SW instrument was also developed. It was used to flare the coronal portion of the root canal system. Wildey WL. Senia ES., Oral Surg Oral Med Oral Pathol1989 Feb:67(2):198-207 Another look at root canal instrumentation. Several aspects of root canal instrumentation need additional research. Various factors must be considered in an analysis of instrumentation of the root canal system: the dentin that is cut: the technique used to cut it: the design of the instruments: the material and manufacturing process used to make the instruments: the irrigant used during the procedure: and the anatomic configuration of the root canal system. An analysis of these factors clearly indicates that existing root canal instruments and techniques are less than ideal and. in fact. do not accomplish what is expected of them. Root canals must be properly. but. at the same time. destructive and unnecessary removal of dentin should be kept to a minimum. The Flex-R and Canal Master instruments were developed to address some of the shortcomings of existing instruments and techniques. More scientifically based research is needed to fully evaluate these new instruments and techniques and to develop future instruments. Wildey WL; Senia ES. Montgomery S., Oral Surg Oral Med Oral Pathol1992 Oct:74(4):499-50799-507

  • PDF

근관형성 기구 및 방법에 따른 근관 형태의 변화 (CHANGES IN ROOT CANAL CONFIGURATION USING DIFFERENT FILE TYPES AND TECHNIQUES)

  • 허영주;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.291-304
    • /
    • 1997
  • The purposes of this study were to evaluate the changes in root canal configuration with canal instrumentation using different file types and techniques and to investigate most appropriate instrumentation technique in maintaining the original canal configuration with different file types. Fifty curved mesiobuccal or distobuccal canals of extracted human maxillary molar teeth were instrumented using a step-back technique with stainless steel K-files or nickel-titanium K-files, a crown-down pressureless technique with stainless steel K-files or nickel-titanium K-files and nickel-titanium engine-driven files. Radiographs were taken before and after instrumentation using a specially designed device that allowed for the pre-and postinstrumentation canals to be taken with the same X-ray angulation. Magnified X-ray images on a magnifier screen were traced and post instrumentation canal images were compared with the preinstrumentation ones. Changes in canal curvature and the incidence of procedural accidents were analyzed. The results were as follows : Crown-down pressureless technique with nickel-titanium K-files and nickel-titanium engine-driven filing produced no significant changes in canal curvature (p>0.05), while the step-back technique with stainless steel K-files or nickel-titanium K-files (p<0.01) and the crown-down pressureless technique with stainless steel K-files (p<0.05) produced significant changes. With nickel-titanium K-file, crown-down pressureless technique produced significantly less changes in canal curvature than step-back technique (p<0.05), while there was no significant difference between techniques with stainless steel K-files (p>0.05). File types exerted no significant influences in the changes of canal curvature both in the step-back technique and crown-down pressureless technique (0>0.05). Regardless of the file types used, step-back technique produced more procedural accidents such as ledge or elbow formation, apical zipping and apical transportation than the crowndown pressureless technique and nickel-titanium engine-driven filing. Both with stainless steel K-files and with nickel-titanium K-files, the incidence of apical extrusion of canal debris was higher in step-back technique than in crown-down pressureless technique.

  • PDF

수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향 (EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE)

  • 이철환;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구 (A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY)

  • 소문섭;임미경;이건일;이용근;이수종
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

Comparison of root canal preparation by three Ni-Ti instruments

  • Shibutani, Takuya;Ozaki, Kazumi;Matsuo, Takashi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.547-547
    • /
    • 2003
  • The aim of this study was to compare the effects of three Ni-Ti instruments on leaning ability by evaluating the volumetric and morphological changes in the apical 6mm of the root canals before and after preparation, using three-dimensionally reconstructed root canals of extracted human teeth. Forty-five teeth were used in this study. They were opened the chambers and removed the all pulp remnants ultrasonically. Subsequently, the canal wall was coated with silver paste and prepared using ProTaper, ProFile and GT rotary files according to the manufacturers instructions. Before and after root canal preparation, all the specimens were scanned with micro computed tomography and examined the differences in dentine volume removed, canal straightening, the proportion of the unchanged area and canal transportation. Quantitative analysis revealed that instrumentation increased in canal volume ranging between 0.081 and $1.866{\;}\textrm{mm}^3$. On average, the large apical preparation produced by ProTaper demonstrated smaller proportions of unchanged surface areas compared to the two other instruments in small canals. But in large canals like maxillary central incisor, the preparation of ProTaper instruments was not enough. ProTaper instrument was tended to increase more in canal volume as compared with the other two instruments but unchanged area was no significant difference. These results showed that three instruments had similar preparation ability and micro computed tomography in combination with the coated wall of root canal using silver paste is a nondestructive and valuable tool to study root canal geometry and changes after preparations in detail.

  • PDF

Ecological health assessment of Mae Kha Canal, Chiang Mai Province, Thailand in 2023

  • Onalenna Manene;Nick Deadman;Chotiwut Techakijvej;Songyot Kullasoot;Pitak Sapewisut;Nattawut Sareein;Chitchol Phalaraksh
    • Journal of Ecology and Environment
    • /
    • 제48권1호
    • /
    • pp.110-119
    • /
    • 2024
  • Background: The Mae Kha Canal is one of Chiang Mai's most important waterways. It supports local agriculture, irrigation, and transportation as well as provides stormwater drainage to prevent floods. Due to the unregulated rapid urbanization of the city and lack of efficient waste and wastewater management systems over the past few decades, the canal has become heavily polluted. This study aimed to evaluate the water quality of Mae Kha canal through assessment of the physico-chemical water quality and coliform bacteria. Moreover, benthic macroinvertebrates were samples and assessed using the Biological Monitoring Working Party (BMWPThai) and Average Score Per Taxon (ASPTThai) as biological indices. Results: The physico-chemical showed low dissolved oxygen levels, high levels of ammonia and phosphates, and elevated levels of biochemical oxygen demand, indicating that the water quality had significantly deteriorated. The canal was found to be heavily polluted, with most sites falling into the polluted to very heavily polluted. Coliform bacteria analysis revealed alarmingly high levels of total coliform bacteria and fecal coliform bacteria in the canal. The BMWPThai and ASPTThai scores indicated poor to very poor water quality. Conclusions: The physico-chemical and coliform bacteria indicated that the water quality of the Mae Kha canal had significantly deteriorated. The biological indices also indicated the poor to very poor water quality. This study underscores the urgent need for comprehensive remediation efforts, emphasizing strategic planning, investment, and community engagement to revive the canal's ecological health and water quality.

극동-북미간 운송비용 분석에 관한 연구 - 파나마운하 확장과 북미 랜드 브릿지를 중심으로 - (Transport Cost Analysis between Far East and North America - Expanded Panama Canal VS American Land Bridge -)

  • 유주영;김태원;곽규석;남기찬
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 추계학술대회 논문집(제1권)
    • /
    • pp.269-274
    • /
    • 2006
  • 최근 파나마 운하 확장이 국민투표로 결정됨에 따라 2014년부터는 12,000TEU급의 선박의 통행이 가능해진다. 파나마운하의 규모적 한계 때문에 포스트 파나막스급이상의 선박들은 파나마 운하대신 아메리칸 랜드브릿지 및 다른 운송루트를 이용해야 했다. 그러나 파나마 운하확장이 확정됨에 따라 향후 극동-북미 간 운송루트의 변화가 불가피할 것으로 예상된다. 따라서 본 연구는 극동-북미 간을 운행하는 선박의 규모별 루트별 총운송비용을 분석하여 두 구간의 경쟁력을 검토한다.

  • PDF

극동-북미간 운송비용 분석에 관한 연구 - 파나마운하 확장과 북미 랜드 브릿지를 중심으로 - (Transport Cost Analysis between Far East and North America - Expanded Panama Canal VS American Land Bridge -)

  • 김태원;곽규석;남기찬;유주영
    • 한국항해항만학회지
    • /
    • 제31권1호
    • /
    • pp.81-87
    • /
    • 2007
  • 최근 파나마 운하 확장이 국민투표로 결정됨에 따라 2014년부터는 12,000TEU급의 선박의 통행이 가능해진다. 파나마운하의 규모적 한계 때문에 포스트 파나막스급이상의 선박들은 파나마 운하대신 아메리칸 랜드브릿지 및 다른 운송루트를 이용해야 했다. 그러나 파나마 운하 확장이 확정됨에 따라 향후 극동-북미 간 운송루트의 변화가 불가피할 것으로 예상된다. 따라서 본 연구는 극동-북미 간을 운행하는 선박의 규모별 루트별 총운송비용을 분석하여 두 구간의 경쟁력을 검토한다.