• 제목/요약/키워드: Can beer

검색결과 71건 처리시간 0.029초

분광분포기반의 광선추적을 이용한 리어램프의 시뮬레이션 (Simulation of Rear Lamp using Spectral-Based Ray Tracing)

  • 이명영;이철희;이호근;하영호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.327-330
    • /
    • 2002
  • This paper proposes the simulation algorithm of rear lamp of car using a ray tracing method that models transmission and refraction of light frequently used in computer graphics At first. To reproduce an image accurately. incident on a sight of viewer, we propose the backward ray tracing method based on spectral distribution representing physical characteristics of illuminant and object used in real. We implement the reproduction algorithm of rear lamp image applying the Bouguer-Beer's law to an optical absorptive phenomenon. As the result, more realistic image can be reproduced.

  • PDF

환경영향을 고려한 WELD BONDING 시험편의 강도평가(인장전단의 경우) (Evaluation of Strength of Weld Bonding Specimen Considering Effects of Environments (In Case of Tensile Shear))

  • Lim, Ki-Chang;Kuen Ha, Shin;S.H. Lim
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.99-107
    • /
    • 1992
  • Weld bonding can be applied as a combined method of spot welding and adhesive to have more advantages than those. Weld bonding has many merits that enlarge the fatigue strength of spot Welding and also improve the creep of adhesive. But it has not beer proved well in the various environmental conditions. In this study, weld bonding test for fatigue properties and tensile strength is presented under such various coditions as temperatures, humidity, and etc.

  • PDF

엽록소 농도 결정을 위하여 측정한 흡광도 값의 신뢰도 검정 지표로서 엽록소 a/b 비례치 (Chlorophyll a/b Ratio as a Criterion for the Reliability of Absorbance Values Measured for the Determination of Chlorophyll Concentration)

  • 오광석;이춘환
    • 생명과학회지
    • /
    • 제29권5호
    • /
    • pp.509-513
    • /
    • 2019
  • 비어 람버트 법칙에 의하면 충분히 묽은 용액에서 주어진 파장에서 측정한 흡광도는 용질의 농도에 비례한다. 반대로 충분히 묽은 용액이란 측정한 흡광도 값이 용질의 농도에 비례관계를 가지는 범위에 있는 용액을 말하지만 실제 확신하기가 어렵다. 본 연구에서는 벼 잎에서 추출한 엽록소 80% 아세톤 용액을 사용하여, 측정한 흡광도 값의 신뢰도를 판단할 수 있는 기준으로서 엽록소 a/b 비례치의 사용 가능성을 4가지 다른 흡광분광분석기(Cary4E, UV-1650PC, Versamax, NanoDrop 100)을 사용하여 조사하였다: 우선 $0.2{\mu}g/ml$의 매우 저농도에서 $200{\mu}g/ml$까지의 다양하게 희석한 엽록소 용액을 사용하여, 645 nm와 663 nm에서 측정한 흡광도 값을 측정한 후, 흡광도 값과 엽록소 농도의 비례관계를 조사하였다. 그 결과, 이 비례관계로 판단한 측정치의 신뢰 범위에서 흡광도로부터 계산한 용액에서의 엽록소 농도와 이미 알고 있는 엽록소 농도 비교적 일치하였다. 그러나, 비례관계의 한계치 안에 있어 신뢰도가 인정된 일부 고농도와 저농도에서의 일부 값이 엽록소 a/b 비례치가 용액의 희석에 변화지 않을 것이라는 판단 기준에 있어 신뢰도가 떨어짐을 알 수 있었다. 그러므로, 본 연구결과는 엽록소 농도결정을 위하여 측정한 흡광도 값의 신뢰 여부는 대상 용액을 희석하여 측정한 흡광도의 비례관계로 본 비어-램버트 법칙의 기준 보다는 엽록소 a/b 비례치가 변하지 않는다는 기준으로 측정치의 신뢰도를 판단하는 것이 더 좋다는 것을 확인할 수 있었다.

Electrical Characteristic and Optical Diagnosis for Atmospheric Direct Plasma Jet

  • Hong, Seong In;Ghimire, B.;Hong, Young Jun;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.155.1-155.1
    • /
    • 2015
  • Nowadays, Plasma has been used in biological, medical such as wound healing, plant grow, killing cancer. When plasma generated, UV light and ROS(Reactive oxygen species), RNS(Reactive nitrogen species) can generated and those things effect to biological material. So we made simple plasma device using needle type of electrode and generated plasma. We used three kinds of gas and measured applied voltage and current. Also we observed optical emission spectrum. Using deuterium ramp, we can observed absorption spectrum and calculated radical density by lambert-beer's law. It is around ~1016cm3. And we can see the time-resolved absorption spectrum from monochromator, PMT(photo multiply tube), IV-converter, oscilloscope.

  • PDF

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

Family Restaurant의 음료 매출증대에 관한 연구 (A Study on a plan of Beverage Sales Step-up of Family Restaurant in Korea.)

  • 이재련
    • 한국조리학회지
    • /
    • 제6권3호
    • /
    • pp.425-442
    • /
    • 2000
  • The main purpose of this study is to propose that Beverage sales should be step-up in Family Restaurant. To achieve the purpose of this study theoretical and empirical approaches were used. In review of theoretical background, basic concepts and characteristics of beverage were studied. For empirical study, three Family Restaurant in Korea was selected and analyzed the beverage sales which classified to Liquor, Beer Wine and Non-alcoholic beverage. Based on it, I suggest a plan of beverage sales step-up of Family Restaurant as follow. First, keep the appropriate valance of the whole item: non-alcohol and alcohol item. Second, develop the menu should be effect beverage sales. Third, through the promotion and event the restaurant should derive the customer to purchasing behavior. Fourth. server can accommodate and offer the information of food and beverage menu that can evoke the customer's attention.

  • PDF

A neural network approach for simulating stationary stochastic processes

  • Beer, Michael;Spanos, Pol D.
    • Structural Engineering and Mechanics
    • /
    • 제32권1호
    • /
    • pp.71-94
    • /
    • 2009
  • In this paper a procedure for Monte Carlo simulation of univariate stationary stochastic processes with the aid of neural networks is presented. Neural networks operate model-free and, thus, circumvent the need of specifying a priori statistical properties of the process, as needed traditionally. This is particularly advantageous when only limited data are available. A neural network can capture the "pattern" of a short observed time series. Afterwards, it can directly generate stochastic process realizations which capture the properties of the underlying data. In the present study a simple feed-forward network with focused time-memory is utilized. The proposed procedure is demonstrated by examples of Monte Carlo simulation, by synthesis of future values of an initially short single process record.

한국산 맥주성분에 관한 연구 (제 1 ) "Total carbohydrates, amino acids 및 peptides 의 정 에 관하여" (Studies on analysis of the Korean lager beers. (I) "On the estimation of total carbohydrates, amino acids and peptides")

  • 한홍의;김종협
    • 미생물학회지
    • /
    • 제6권2호
    • /
    • pp.63-67
    • /
    • 1968
  • Total carbohydrates, amino acids and peptide-like substances in two kinds of Korean lager beers have been analyzed by the calorimetric method of Dreywood's anthrone reagent and Fowden's ninhydrin reagent. The samples were fractionated with column of ion-exchange resin. The experimental results are as follows; 1. Amounts of non-hydrolyzed carbohydrates in the part of column processed is 1. 82% and 1. 96 % (the value was measured by Bertrand's method). But the amounts of those measured by Dreywood's anthrone method are 5.57% and 4.25%, this values are much more than those of Bertrand's method. 2. It can be estimated the amounts of gum and dextrin are 3.75% and 3.30% in both two beers, by comparison of samples with the above mentioned two method. 3. The amounts of carbohydrates by anthrone reagent in acid-hydrolyzed beers are much increased than those of non-hydrolyzed, so it is suggested the presence of polymer carbohydrates which couldn't be detected by Bertrand's method. 4. Total amounts of amino acids are 0.015% and 0.025% (as glycine) in non-hydrolyzed beers measured by ninhydrine color reaction method, on the other hand the amount of amino acids in acid hydrolyzed beers are 0.06% and 0.056%, this is much more than those of nonhydrolysis. The different amounts means that of peptide-like substances. 5. It is necessary to determine the constituent of amino acid for the better taste of beer, and also it is desirable to check the role of carbohydrates in the course of fermentation, mashing and on lager beer for effective utilization of carbohydrate materials to eliminate the losses.

  • PDF

스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구 (A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.

혼합성분중(混合成分中) Ethinyl Estradiol과 Norethindrone Acetate의 분리정량(分離定量) (Isolative Determination of Ethinyl Estradiol and Norethindrone Acetate in the Mixed Preparations)

  • 이정현;용재익
    • Journal of Pharmaceutical Investigation
    • /
    • 제1권1호
    • /
    • pp.47-52
    • /
    • 1971
  • Application of the spectrophotometer to the analysis of 17 ${\alpha}-ethinyl$ estradiol and $17{\alpha}-ethinyl-19-nortestosterone$ acetate mixture in oral contraceptive has been accomplished. It is used Beckman Du Spectrophotometer as a apparatus. The petroleum ether extract of ethinyl estradiol is determined at $535\;m{\mu}$ and the chloroform extract of norethindrone acetate is determined at $380\;m{\mu}$ respectively. This analytical method is formed Lambert Beer's law. This method can be used to the analysis of ethinyl estradiol aid norethindrone acetate mixture in commercial dosage form of routine assay.

  • PDF