• Title/Summary/Keyword: Camphorquinone

Search Result 17, Processing Time 0.028 seconds

Effect of Photo-accelerator on the Dental Properties of Acryl-based Polymeric Dental Restorative Composites (아크릴계 고분자 치아수복재의 치과적 물성에 미치는 광증감제 효과)

  • Kim, Ohyoung
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.117-122
    • /
    • 2005
  • The aim of this study was to evaluate the effect of tertiary amine photo-accelerator on the dental properties of visible light-activated, polymeric, dental restorative composites (PDRC) through the measurement of mechanical and esthetic properties. The surface of barium silicate was hydrophobically treated to improve the interfacial behavior with the acrylic resin matrix. Camphorquinone was adopted as a photo-initiator with 0.5 wt% based on the resin matrix. It was discovered that the dental properties of PDRC were primarily dependent on the chemical structure rather than the added content of photo-accelerator.

Effect of the difference in spectral outputs of the single and dual-peak LEDs on the microhardness and the color stability of resin composites (Single-peak LED와 dual-peak LED의 출력 파장 차이가 복합 레진 미세 경도와 색 안정성에 미치는 영향)

  • Park, Hye-Jung;Son, Sung-Ae;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.108-113
    • /
    • 2011
  • Objectives: To determine the effect of the spectral output of single and dual-peak light emitting diode (LED) curing lights on the microhardness and color stability of commercial resin composites formulated with camphorquinone and alternative photoinitiators in combination. Materials and Methods: Three light-polymerized resin composites (Z100 (3M ESPE), Tetric Ceram (Ivoclar Vivadent) and Aelite LS Posterior (Bisco)) with different photoinitiator systems were used. The resin composites were packed into a Teflon mold (8 mm diameter and 2 mm thickness) on a cover glass. After packing the composites, they were light cured with single-peak and dual-peak LEDs. The Knoop microhardness (KHN) and color difference (${\Delta}E$) for 30 days were measured. The data was analyzed statistically using a student's t-test (p < 0.05). Results: All resin composites showed improved microhardness when a third-generation dual-peak LED light was used. The color stability was also higher for all resin composites with dual-peak LEDs. However, there was a significant difference only for Aelite LS Posterior. Conclusions: The dual-peak LEDs have a beneficial effect on the microhardness and color stability of resin composites formulated with a combination of camphorquinone and alternative photoinitiators.

Tooth-colored Restorative Resin Composites (임상가를 위한 특집 2 - 심미수복용 레진)

  • Kwon, Tae-Yub
    • The Journal of the Korean dental association
    • /
    • v.51 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Curing methods for denial resin-based materials are limited because of the need to polymerize quickly in the oral cavity at an ambient temperature. At present, most dental restorative composites use a camphorquinone-amine complex initiation, visible light-cure, one-component systems. Clinically, it is important to try to optimize the degree of conversion of res in composites using proper manipulation and adequate light-curing techniques to ensure the best outcome.

Photochemical Reduction of 1,2-Diketones in the Presence of $TiO_2$

  • Park, Jun U;Hong, Mi Jeong;Go, Park Gwang Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.11
    • /
    • pp.1213-1216
    • /
    • 2001
  • 1,2-Diketones, camphorquinone and 1-phenyl-1,2-propanedione, are converted to the corresponding $\alpha-hydroxyketones$ in moderate to good yields by TiO2-catalyzed photochemical reactions in deoxygenated alcoholic media. The reduction yield for 1-phenyl-1,2-propanedione is considerably increased by addition of water or triethylamine

The effect of 4,4'-bis(N,N-diethylamino)benzophenone on the degree of conversion in liquid photopolymer for dental 3D printing

  • Lee, Du-Hyeong;Mai, Hang Nga;Yang, Jin-Chul;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.386-391
    • /
    • 2015
  • PURPOSE. The purpose of this preliminary study was to investigate the effects of adding 4,4'-bis(N,N-diethylamino) benzophenone (DEABP) as a co-initiator to a binary photoinitiating system (camphorquinone-amine) to analyze on the degree of conversion (DC) of a light-cured resin for dental 3D printing. MATERIALS AND METHODS. Cylindrical specimens (N=60, n=30 per group, ${\phi}5mm{\times}1mm$) were fabricated using bisphenol A glycerolate dimethacrylate (BisGMA) both with and without DEABP. The freshly mixed resins were exposed to light in a custom-made closed chamber with nine light-emitting diode lamps (wavelength: 405 nm; power: $840mW/cm^2$) for polymerization at each incidence of light-irradiation at 10, 30, 60, 180, and 300 seconds, while five specimens at a time were evaluated at each given irradiation point. Fourier-transform infrared (FTIR) spectroscopy was used to measure the DC values of the resins. Two-way analysis of variance and the Duncan post hoc test were used to analyze statistically significant differences between the groups and given times (${\alpha}$=.05). RESULTS. In the DEABP-containing resin, the DC values were significantly higher at all points in time (P<.001), and also the initial polymerization velocity was faster than in the DEABP-free resin. CONCLUSION. The addition of DEABP significantly enhanced the DC values and, thus, could potentially become an efficient photoinitiator when combined with a camphorquinone-amine system and may be utilized as a more advanced photopolymerization system for dental 3D printing.

Esthetic Properties of Photoinitiated Polymeric Dental Restorative Nanocomposites (광중합형의 치아수복용 고분자 나노복합체의 심미 특성)

  • Kim, Oh-Young;Han, Sang-Hyuk;Kim, Chang-Keun
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.102-105
    • /
    • 2005
  • Photoinitiated polymeric dental restorative nanocomposites (PDRNC) were designed to be useful for the variety of dental restoration. Hybrid-filler composed of barium silicate (avg. dia.:1 ${\mu}m$) and nano-sized silica (avg. dia: 40 and 7 nm) was adopted as a filler system. To improve the interfacial behavior with the resin matrix of bisphenol A glycerolate methacrylate/triethyleneglycol dimethacrylate (60/40 wt%), the surface of the filler was hydrophobically treated with a silane coupling agent. A visible light system of camphorquinone photo-initiator and 2-(dimethylamino)ethyl methacrylate photo-accelerator was utilized to activate the PDRNC. Esthetic properties of PDRNC was investigated by measuring the Hunter L, a, b values and it was discovered that PDRNC produced in this work showed excellent esthetic properties with an increase in 7 nm nanofiller content.

A Study on new Photoinitiator of Visible Light Dental Composite Resin (치과용 가시광선 중합형 복합수지의 새로운 광개시제에 관한 연구)

  • Choi, Yong-Seok;Sun, Gum-Ju
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.49-59
    • /
    • 2002
  • The photopolymerization efficiency and surface hardness of composite resin containing 1,2-phenylpropanedione (PD) and diacetyl (DA) as photoinitiators were studied by IR and Vickers hardness and the results were compared with that of camphorquinone (CQ). Relative photopolymerization efficiency of the photoinitiators increased in the order of DA < CQ < PD. Vickers hardness of composite resin containing the photoinitiators increased in the order of CQ < PD < DA. Thus, PD is a new visible light photoinitiator for dental composite resin with higher photopolymerization efficiency and surface hardness than that of CQ. Mechanical properties such as Vickers hardness, diametral tensile strength, and flexural strength of the experimental resin composite prepared by addition of the photosensitizer into a resin of bis-GMA improved with increasing the photosensitizer content and irradiation time. The resin composite of bis-GMA containing DA or PD shows better mechanical properties than that of CQ.

  • PDF

Photopolymerization efficiency of dental resin composites with new mixed photosensitizers (새로운 혼합형 광증감제를 사용한 치과용 복합수지의 중합효율에 관한 연구)

  • Sun, Gum-Ju;Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2004
  • Two diketones, 1-phenyl-1,2-propanedione(PD) and 2,3-butanedione (BD) were investigated as new visible light photosensitizers for a dental resin composite of bis-GMA in order to improve photopolymerization effect. And the photopolymerization efficiency of mixed photosensitizers, PD-CQ and DA-CQ, was studied. Photopolymerization effect of photosensitizers were compared with that of camphorquinone(CQ), the most widely used photosensitizer. The photopolymerization efficiency of bis-GMA containing the photosensitizer increased with irradiation time. The increase was in the order: BD < CQ < PD. The photopolymerization efficiency of this mixture was not so efficient as CQ or PD.

  • PDF

Characteristics of polymerization in nanofiller-containing composite resins (나노필러를 포함하고 있는 복합레진의 중합특성)

  • Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.9-15
    • /
    • 2007
  • As the development of nanotechnology, the use of composite resins which containing nanofillers becomes popular. The purpose of this study was to test the degree of polymerization of nanofillercontaining composite resins. For the study, three different nanofiller-containing composite resins and two different light-curing units were used. To evaluate the degree of polymerization, the maximum polymerization shrinkage taking place during the light curing, and the microhardness, after the light curing, were measured. As results, two light-curing units exhibited a similar emission spectrum to that of the included photoinitiator, camphorquinone. The only difference between the light-curing units were the width of the emission spectrum. Three different composite resins showed different microhardness values. Among them, Grandio showed the greatest microhardness value. However, there was less microhardness difference on the top and bottom surfaces due to the difference of the light-curing units. The maximum polymerization shrinkage values were also similar in the tested specimens regardless of the difference of the light-curing units. However, Grandio showed the least polymerization shrinkage. According to the manufacturers' data, Grandio showed the highest filler content(vol%).

  • PDF