• Title/Summary/Keyword: Camera constant

Search Result 180, Processing Time 0.026 seconds

Vehicle Plate Extraction Using Wavelet Transform and Polarized Light Filter (웨이브렛 변환과 편광 필터를 이용한 차량번호판 축출)

  • 김옥규;이창윤;황형덕;강혜진;박영식
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.102-105
    • /
    • 2003
  • Up to the present studies of the car number recognition system, it is generally known to have serious problems such as relatively long processing time due to the excessive length of data extracted from the number plate based on the current image characteristics, and the image blurring with the physical damage of the brightness and darkness signals of the number plate caused by external impulses with many difficulties in the extraction of the highlighted numbers. In this Paper we used the characteristics firstly having a constant brightness of number plate, and a high density to the horizontal axis, and the influences of highlighted signal could be reduced by making reflections less through the polarized filter on the camera for any highlighted signal. For the more, the data processing time and the noise reduction are effectively implemented by using the wavelet transform of time-space scale with the considerations on the physical loss and processing time.

  • PDF

Experimental Study on Evaporation and Combustion Characteristics of Fuel Droplet with Carbon Nano-particle in RCM (급속압축장치에서 탄소 나노입자가 첨가된 연료 액적의 증발 및 연소 특성에 관한 실험적 연구)

  • Ahn, Hyeongjin;Won, Jonghan;Beak, Seungwook;Kim, Hyemin
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.209-211
    • /
    • 2015
  • Evaporation characteristics of a single droplet of carbon nanofluids were investigated in a rapid compression machine(RCM). n-Heptane and carbon black N990 were used to synthesize the carbon nanofluids. RCM is an experimental set-up to simulate a single compression stroke of reciprocating engine. Temperature and pressure in a reaction chamber were measured during the compression stroke. After the piston reaches top dead center(TDC), temperature and pressure decreased due to the heat loss at wall. In that process, a single droplet of carbon nanofluids underwent unsteady condition. A single droplet was put at the center of reaction chamber. Thermocouple whose tip is $50{\mu}m$ was used not only to measure transient bulk temperature, but also to suspend the droplet. The picture of single droplet was taken using high speed camera with a frame rate of 500 fps. From those pictures, the droplet diameter was measured by visual basic program.

  • PDF

The Suggestion of the Image Registration Using Terrain Relief Correction Based on RFM (유리함수모델 기반 표고시차보상기법을 사용한 Image Registration 방안 제안)

  • Kim, Hyun-Suk;Kim, Moon-Gyu;Seo, Doo-Chun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.21-30
    • /
    • 2012
  • When two bands have different look angle in a space-borne camera system, the registration between two bands is required. The registration cannot be modeled with constant parameters because of dynamic of platform and parallax effect. The parallax effect is caused by terrain relief, hence it causes local distortion between two bands. Therefore, the terrain relief correction in order to reduce the parallax effect is required for better registration result, especially for high resolution image data. Such terrain relief correction also can be applied to image data acquired from multiple detectors with different look angle within a band, which is a one of commonly used configuration for a wider swath in space-borne camera system, in order to reduce the distortion between detectors. The RFM is a popular abstract model in remote sensing field, which gives us the relationship between the image plane and geodetic coordinate system. Therefore, we propose a terrain relief correction method based on the RFM. The experiment showed very promising result.

Development of Terrestrial Photogrammetric Technique for Structure Monitoring (구조물 monitoring을 위한 지상사진측량기법의 개발)

  • Han, Seung Hee;Kang, Joon Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.151-160
    • /
    • 1994
  • Recently, terrestrial photogrammetry has been applied effectively to data acquisition in GIS and to monitoring precise machinery for simulation test. Because 3-D coordinates of many object points can be quickly measured with constant accuracy and easy modeling by this method. In this study, the composition concerned with multi-camera system which simultaneously analyzes structure from multi-station using various cameras was developed. The errors of results were analyzed to investigate the accuracy of the system, error of unknown points and control points, convergent and strip adjustment for optimal network design also. As results of this study, the efficiency of multi-camera system developed here was proved through application to monitoring the entire area of the precise model ship. We could also acquire 3-dimensional coordinates with good accuracy by arranging pass points. Therefore, possibility of measurement of instantaneous deformation as well as precision analysis of structures can be suggested.

  • PDF

Development of Hydrophilic Performance Measurement System for Anti-Condensation Using Computer Image (컴퓨터 영상을 이용한 오염방지 친수성능 측정 시스템 개발)

  • Ahn, Byung-Tae;Cho, Sung-Ho;Choi, Sun;Kim, Eun-Kuk;Park, Sang-Soo;Hwang, Heon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.257-261
    • /
    • 2010
  • Surface energy is the principal factor of anti-condensation. High surface energy appears hydrophilic itself and low surface energy represents hydrophobic itself. The contact angle is widely being used for measurement of surface energy of materials, evaluation of coating performances, measurement of wettability, and so on. However, the existing contact angle measuring system is so expensive for purchasing and complicated, so it takes a lot of time and money to use. This study was conducted to develop the algorithm for evaluating hydrophilic performance through measuring the contact angle of water droplet automatically, and fabricate relatively simple measuring system using a low-cost monochrome camera and image processing. A constant amount of water was firstly allocated on a slide by a micropipette, and then the image of water droplet was captured by monochrome digital camera and sent to a computer. The image was binarized and then reduced noises by labeling. Finally, the contact angle of water droplet was computed by using three points (left, right, and top coordinates), simple linear mathematics, and trigonometric function. The experimental results demonstrated the accuracy and reproducibility of the developed system showing less deviations and deviation ratio.

Bayesian Sensor Fusion of Monocular Vision and Laser Structured Light Sensor for Robust Localization of a Mobile Robot (이동 로봇의 강인 위치 추정을 위한 단안 비젼 센서와 레이저 구조광 센서의 베이시안 센서융합)

  • Kim, Min-Young;Ahn, Sang-Tae;Cho, Hyung-Suck
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.4
    • /
    • pp.381-390
    • /
    • 2010
  • This paper describes a procedure of the map-based localization for mobile robots by using a sensor fusion technique in structured environments. A combination of various sensors with different characteristics and limited sensibility has advantages in view of complementariness and cooperation to obtain better information on the environment. In this paper, for robust self-localization of a mobile robot with a monocular camera and a laser structured light sensor, environment information acquired from two sensors is combined and fused by a Bayesian sensor fusion technique based on the probabilistic reliability function of each sensor predefined through experiments. For the self-localization using the monocular vision, the robot utilizes image features consisting of vertical edge lines from input camera images, and they are used as natural landmark points in self-localization process. However, in case of using the laser structured light sensor, it utilizes geometrical features composed of corners and planes as natural landmark shapes during this process, which are extracted from range data at a constant height from the navigation floor. Although only each feature group of them is sometimes useful to localize mobile robots, all features from the two sensors are simultaneously used and fused in term of information for reliable localization under various environment conditions. To verify the advantage of using multi-sensor fusion, a series of experiments are performed, and experimental results are discussed in detail.

Developments of the Wide Wavelength Range Polarimeter of the Domeless Solar Telescope at the Hida Observatory

  • Anan, Tetsu;Ichimoto, Kiyoshi;Oi, Akihito;Ueno, Satoru;Kimura, Goichi;Nakatani, Yoshikazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • We are developing a new universal spectropolarimeter on the Domeless Solar Telescope (DST) at the Hida Observatory to realize precise spectropolarimetric observations in a wide range of wavelength in visible and near infrared. The system aims to open a new window of plasma diagnostics by using Zeeman effect, Hanle effect, Stark effect, impact polarization, and atomic polarization for measuring the external magnetic field, electric field, or an anisotropy in the excitation of the atoms. The polarimeter is a successor of formerly developed polarimeter on DST, which make possible to observe a polarization in a photospheric spectral line with polarimetric accuracy of 10-2 (Kiyohara et al. 2004). The new system consists of a 60cm aperture vacuum telescope, a high dispersion vacuum spectrograph, polarization modulator / analyzer composed of a rotating waveplate whose retardation is constant for a wide range of wavelength and Wallaston prism, and a fast and large format CCD camera or IR camera. Spectral images in both orthogonal polarizations are taken simultaneously with a frame rate of ~20Hz while the waveplate rotates continuously in a rate of 1rev./sec. Thus It takes 5 ~ 60 sec to observe polarization with accuracy of 10-3 in a wide wavelength range (400 - 1100nm). We also examined a polarimetric model of the telescope with accuracy of 10-3 to calibrate instrumental polarization on some wavelengths. In this talk, I will focus on the performance of the instrument.

  • PDF

Calibration of monodisperse polystylene spheres of size from 1 to 10 ${\mu}m$ by using optical array sizing method (광학적 입자열 측정법에 의한 폴리스티렌구의 평균지름 측정)

  • 강주식
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • The technique for calibrating standard particles larger than 1 $\mu$m by using an optical array sizing method has been established. The system consists of an optical microscope with transmission light source, a CCD camera, and a computer equipped with a frame grabber. The center distance between two spheres located at both ends of a row which consists of N spheres is measured in terms of pixel numbers, and divided by (N-1) to obtain the average pixel numbers per particle. This value is multiplied by length conversion constant, which has been determined in advance, to obtain the mean diameter of polystylene spheres. The length conversion constant is found from the microscopic image of calibrated standard stage micrometer plate. In order to reduce error in finding center positions of the scale and particles in the image, a software filter which dilates bright (or dark) object has been used. Spheres having nominal size of 1, 2, 3, 5, and 10$\mu$m were measured, and the maximum deviation of the measured mean diameter valus from their certified values was 0.7%. Standard particles which is larger than 1 $\mu$m can be calibrated by this method with measuredment uncertainy (k=2) lees than 1.53%.

  • PDF

Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector (수직 오리피스 이젝터의 혼합유동 및 산소전달 특성)

  • Kim, Dong Jun;Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.61-69
    • /
    • 2015
  • The objective of this study is to experimentally investigate the mixed flow behaviors and oxygen transfer characteristics of a vertical orifice ejector. The experimental apparatus consisted of an electric motor-pump, an orifice ejector, a circulation water tank, an air compressor, a high speed camera unit and control or measurement accessories. The mass ratio was calculated using the measured primary flow rate and suction air flow rate with experimental parameters. The visualization images of vertically injected mixed jet issuing from the orifice ejector were qualitatively analyzed. The volumetric oxygen transfer coefficient was calculated using the measured dissolved oxygen concentration. At a constant primary flow rate, the mass ratio and oxygen transfer coefficient increase with the air pressure of compressor. At a constant air pressure of the compressor, the mass ratio decreases and the oxygen transfer coefficient increases as the primary flow rate increases. The residence time and dispersion of fine air bubbles and the penetration of mixed flow were found to be important parameters for the oxygen transfer rate owing to the contact area and time of two phases.

The effects of Gasoline-Biodiesel Blended Fuels on Spray Characteristics (스프레이 특성에 가솔린 - 바이오 디젤 혼합 연료의 효과)

  • THONGCHAI, SAKDA;LIM, OCKTAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.3
    • /
    • pp.287-293
    • /
    • 2015
  • The current study has investigated the effects of biodiesel blended with gasoline on the spray characteristics in a Constant Volume Combustion Chamber (CVCC). With the concentration of 5, 10, 15 and 20% by volume, biodiesel was blended with commercial gasoline and performed on the macroscopic visualization test. Pure gasoline and biodiesel were also tested as the reference. The shadowgraph technique was conducted in the constant volume chamber. The spray images were recorded by a high speed video camera with frame speed 10,000 frame per second. Fuel injection was set at 800, 1000 and 1,350 bar with the simulated speed 1,500 and 2,000 rpm. The back pressure was controlled at 20 bar. The spray angle and penetration tip were measured and analyzed by using the image processing. At the high injection pressure, the spray penetration length with the simulated speed 1,500 rpm showed that B100 was lower than GB00-20 whereas the spray penetration length with the simulated speed 2,000 rpm exhibited that GB blends and B100 were insignificantly different. Due to biodiesel concentration, its effects on spray angles were observed throughout injection periods (T1, T2 and T3). At the simulated speed 1,500 rpm, the spray angle of GB blends and B100 presented the same pattern following injection timing. In addition, when the simulated speed increased to 2,000 rpm the different spray angle of all blends disappeared at main injection (T3).