• Title/Summary/Keyword: Cam-in-Cam

Search Result 2,323, Processing Time 0.026 seconds

Effect of coloring agent on the color of zirconia (Coloring agent가 지르코니아 색조 재현성에 미치는 영향)

  • Kim, Kwanghyun;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.18-25
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the effect of two types of coloring agents and the number of application on the color of zirconia. Materials and methods: Monolithic zirconia specimens ($15.7mm{\times}15.7mm{\times}2.0mm$) (n = 33) was prepared and divided into 11 groups. Each experimental group was coded as a1-a5, w1-w5 according to the type of coloring agent and number of application. Specimens with no coloring agent applied were set as control group. The color difference of specimen was measured by using double-beam spectrophotometer, and calculated color difference (${{\Delta}E^*}_{ab}$), translucency parameter (TP). All data was analyzed with two-way ANOVA, multiple comparison $Sch{\acute{e}}ffe$ test, Pearson correlation and linear regression analysis. Results: As the number of application increased, values of $CIE\;L^*$ was decreased, but values of $CIE\;b^*$ was increased in both coloring agents. However, there was no significant difference on values of translucency parameter. The color difference range of each group was ${0.87{\Delta}E^*}_{ab}$ to ${9.43{\Delta}E^*}_{ab}$. Conclusion: In this study, type of coloring agent and the number of application did not affect the color difference of zirconia.

Digital Video Source Identification Using Sensor Pattern Noise with Morphology Filtering (모폴로지 필터링 기반 센서 패턴 노이즈를 이용한 디지털 동영상 획득 장치 판별 기술)

  • Lee, Sang-Hyeong;Kim, Dong-Hyun;Oh, Tae-Woo;Kim, Ki-Bom;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • With the advance of Internet Technology, various social network services are created and used by users. Especially, the use of smart devices makes that multimedia contents can be used and distributed on social network services. However, since the crime rate also is increased by users with illegal purposes, there are needs to protect contents and block illegal usage of contents with multimedia forensics. In this paper, we propose a multimedia forensic technique which is identifying the video source. First, the scheme to acquire the sensor pattern noise (SPN) using morphology filtering is presented, which comes from the imperfection of photon detector. Using this scheme, the SPN of reference videos from the reference device is estimated and the SPN of an unknown video is estimated. Then, the similarity between two SPNs is measured to identify whether the unknown video is acquired using the reference device. For the performance analysis of the proposed technique, 30 devices including DSLR camera, compact camera, camcorder, action cam and smart phone are tested and quantitatively analyzed. Based on the results, the proposed technique can achieve the 96% accuracy in identification.

Precision Evaluation of Scanning the Digital Dental Abutment Impression and Dental Gypsum Model according to 3-dimensional Superimposing Different Skills (3차원 중첩 기술 차이에 따른 디지털 치과용 지대치 인상체 및 경석고 모형의 스캐닝 정밀도 평가)

  • Jeon, Jin-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.639-645
    • /
    • 2018
  • The objective of this research was to compare the precision of scanning the digital abutment impression and gypsum model according to 3-dimensional superimposing different skills. There were made with the abutment impression and gypsum model of a maxillary 1st premolar, blue light scanner scanned to obtain the stereolithography (STL) file. After the same process was performed 10 more times without moving them on the scanner table about the abutment impression and gypsum model, respectively (n=11, per types). By superimposing the date of scanning the abutment impression and gypsum model used with no control and best-fit-alignment skills, 10 color-difference maps and root mean square (RMS) data were obtained. The independent t-test was performed to compare RMS data between the each other groups (${\alpha}=0.05$). In the scanning abutment impressions, $RMS{\pm}SD$ of no control, best-fit-alignment showed $6.86{\pm}0.94$, $5.04{\pm}0.24$. in the scanning gypsum model, $4.98{\pm}1.16$, $3.39{\pm}0.07$, all groups showed a significant difference (P<0.001). Trough the this study's result, not only best-fit-alignment but no control is used with digital dental computer-aided design/computer-aided manufacturing (CAD/CAM) research and clinical part.

Application of various digital technique on full mouth rehabilitation: A case report (디지털 기술을 활용한 전악 고정성 보철 수복 증례)

  • Bae, Min-Soo;Song, Kwang-Yeob;Ahn, Seung-Geun;Park, Ju-Mi;Lee, Jung-Jin;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.43-54
    • /
    • 2021
  • Based on rapid improvement in digital fields, many advanced digital technologies are utilized in prosthodontic treatment. Especially, intraoral scanners and 3D printing technology are commonly used, and facial scanning technology is recently being attempted to be part of these digital routines. This case report aims to introduce a digital procedure using the intraoral scanner, facial scanner, and 3D printing technology to create definitive restorations, which are esthetic and harmonious with patient's face. From thoroughly evaluated full-mouth provisional restoration which was manufactured and fitted conventionally, definitive prostheses were fabricated using various digital technique. Stable occlusion with functionally and aesthetically satisfying results were achieved.

Posterior rehabilitation considering mandibular movement with digital facebow transfer and virtual articulator: A case report (디지털 안궁이전과 가상교합기를 이용하여 하악의 운동을 고려한 구치부 수복 증례)

  • Kim, Min-Beom;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.431-441
    • /
    • 2022
  • The digital facebow device records the trajectory of the mandibular movement where it is then reflected on the computer-aided design software, leading to an improvement on treatment outcomes of prosthetic restorations. In this clinical case, using a digital technology, an implant placement and prosthetic restoration were done in a patient who has lost maxillary and mandibular molars. Following an intraoral scan, a surgical stent for implant surgery was fabricated based on digital diagnostic wax-up, and implants were installed. After six months of sufficient osseointegration, customized abutments and the first temporary prostheses were delivered. Then two months later, at an abutment level, an intraoral scan and digital facebow transfer device were used to mount the intraoral scan data on a virtual articulator, and record the mandibular movements. Once the second temporary prostheses were fabricated and delivered on a basis of the mandibular movement, the definitive zirconia prostheses were designed and delivered based on a stabilized occlusion that was duplicated via double scan technique.

Implant-assisted removable partial denture using Milled-Bar and Attachment in partially edentulous maxilla: A case report (상악 부분 무치악 환자에서 Milled-bar와 어태치먼트를 이용한 임플란트 부분 피개의치 수복 증례 보고)

  • Jeong, Yun-Su;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.412-419
    • /
    • 2022
  • For treatment of partially edentulous patients, a treatment using implant is widely used. Treatment method using implant are implant fixed prostheses and removable partial dentures, and for patients with severe bone resorption, removable implant overdenture with the effects of aesthetic and reducing cost can be used as treatment options. Specially, prosthesis with milled-bar and attachment has the effect of being splinted between implant fixtures, higher retention and stability than conventional removable partial denture. And it has the effect of improvement of aesthetic through lip support by denture base. In this case, the patient with severe alveolar bone resorption and partial edentulous maxilla and mandible was treated by implant-assisted removable partial denture using Milled-bar and ADD-TOC attachment. The esthetic was improved by removing the clasp because of effects of additional retention by using the attachment, and reducing palatal coverage of implant-assisted removable partial denture. The clinical results were satisfactory on the aspect of aesthetic and masticatory function.

Test Set Construction for Quality Evaluation of NAK Portal's Search Service and the Status Analysis (국가기록포털 검색서비스 품질 점검을 위한 평가셋 구축 및 현황 분석)

  • Jeong Ho, Na;Hyeon-Gi, So;Gyung Rok, Yeom;Jung-Ok, Lee;Hyo-Jung, Oh
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.4
    • /
    • pp.25-43
    • /
    • 2022
  • The ultimate record management's purpose is preservation and utilization. However, the National Archives of Korea (NAK)s Portal has problems such as search system aging and search tools dualization. As a result, the users' search satisfaction is not satisfied, and the improvement demand increases. This study aimed to evaluate the NAK's search quality as a preliminary study for NAK search system advancement. To this end, we analyzed the current status of CAMS and NAK's Portal. Then, we established the test sets and evaluated the NAK's Portal quality from the user's point of view. Evaluation results were analyzed using Precision, Recall, F-score, and MRR. The analysis results showed that the overall search performance was low, particularly in the "advanced subject search," which showed low performance in Precision, Recall, and MRR. Thus, improvement is urgently needed. The test sets established for this study are expected to be used as a basis for objectively measuring the improvement of the search performance after the NAK search system advancement.

Implant surgery and prosthodontic treatment of Temporomandibular disorder patient combined SERAFIN clear aligner system : Clinical case report (세라핀 투명교정 시스템을 활용한 교합 장애 및 치아 결손 증례의 치료)

  • Won-Gun, Chang
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Adult patients who need implant and prosthodontic treatment often need treatment to improve the existing occlusion through orthodontic treatment for long-term stable treatment results. However, due to non-aesthetic and uncomfortable orthodontic treatment with orthodontic brackets and wires, many adult patients give up treatment even though they know the need for it. Recently, as digital dentistry has affected all areas of dentistry, clear aligner orthodontic systems have begun to be widely used, and their use is increasing in adults and old-aged people due to the esthetic advantage and convenient oral care. SERAFIN clear aligner system developed in Korea has been developed with the aim of implementing a functional occlusion harmony and is used not only for partial orthodontic treatment but also comprehensive orthodontic treatment. This patient presentation is shown the treatment using SERAFIN clear aligner system for the treatment of patient with TMD, severe extrusion of maxillary second molars, and extracted teeth.

Composition and Cytotoxicity of Essential Oil from Korean rhododendron (Rhododendon mucronulatum Turcz. var. ciliatum Nakai) (털진달래(Rhododendon mucronulatum Turcz. var. ciliatum Nakai) 정유의 성분분석과 독성평가)

  • Park, Yu-Hwa;Kim, Song-Mun
    • Applied Biological Chemistry
    • /
    • v.51 no.3
    • /
    • pp.233-237
    • /
    • 2008
  • The essential oil was obtained from the aerial part of Rhododendon mucronulatum Turcz. var. ciliatum Nakai by steam distillation, samples were collected by headspace (HS) and solid-phase microextraction (SPME) methods, and the compositions of the oil were analyzed by gas chromatography-mass spectrometry (GC-MS). Nineteen constituents were identified from the essential oil: 15 carbohydrates, 3 alcohols, and 1 acetates. Major constituents were 2-${\beta}$-pinene (16.1%), camphene (11.9%), ${\delta}$-3-carene (11.4%), d,l-limonene (9.5%), and ${\gamma}$-terpinene (9.5%). By SPME extraction, seventeen constituents were identified: 13 hydrocarbons, 1 alcohol, 1 nitrogen-containing compound, 1 acetate, and 1 amine. Major constituents of the SPME-extracted sample were cam phene (19.6%), 2-${\beta}$-pinene (18.0%), ${\delta}$-3-carene (17.4%), trimethyl hydrazine (9.7%), ${\gamma}$-terpinene (8.5%), and d,l-limonene (5.5%). By HS extraction, thirteen constituents were identified: 11 hydrocarbons, 1 alcohol, and 1 nitrogen-containing compound. Major constituents of the HS-extracted sample were camphene (25.8%), ${\delta}$-3-carene (24.8%), 2-${\beta}$-pinene (20.2%), d,l-limonene (5.4%), tricyclene (5.1%) and trimethyl hydrazine (4.6%). The fragrance of the essential oil was coniferous, balsamic, and woody, and the $IC_{50}$ value of the essential oil was 0.030 ${\mu}g/mg$ in MTT assay using UaCaT keratinocyte cell line.

Three-Dimensional Kinematic Model of the Human Knee Joint during Gait

  • Mun, Joung-Hwan;Seichi Takeuchi
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.171-179
    • /
    • 2002
  • It is well known that the geometry of the articular surface plays a major role in the kinematic and kinetic analysis to understand human knee joint function during motion. The functionality of the knee joint cannot be accurately modeled without considering the effects of sliding and lolling motions. We Present a 3-D human knee joint model considering sliding and rotting motion and major ligaments. We employ more realistic articular geometry using two cam profiles obtained from the extrusion of the sagittal Plain view of the representative Computerized Tomography image of the knee joint compared to the previously reported model. Our model shows good agreement with the already reported experimental results on Prediction of the lines of force through the human joint during gait. The contact point between femur and tibia moves toward the Posterior direction as the knee undergoes flexion, reflecting the coupling of anterior and Posterior motion with flexion/extension. The anterior/posterior displacement of the contact Point on the tibia plateau during one gait cycle is about 16 mm. for the lateral condyle and 25 mm. for the medial condyle using the employed model Also. the femur motion on the tibia undergoes lateral/medial movement about 7 mm. and 10 mm. during one gait cycle for the lateral condyle and medial condyle. respectively. The developed computational model maybe Potentially employed to identify the joint degeneration.