• 제목/요약/키워드: Calorimetry

검색결과 1,162건 처리시간 0.03초

Crystal Forms of Ketorolac

  • Sohn, Young-Taek;Seo, Hyun-Ok
    • Archives of Pharmacal Research
    • /
    • 제27권3호
    • /
    • pp.357-360
    • /
    • 2004
  • Four crystal forms of ketorolac have been obtained by recrystallization in organic solvents under variable conditions. Different ketorolac polymorphs and pseudo polymorph were characterized by X-ray powder diffraction crystallography (XRD), Differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). In the dissolution studies in water at $37{\pm}0.5^{\circ}C$ four crystal forms showed different patterns. The solubility of Form I were the highest. The solubility decreased in rank order: Form I> Form II > Form III > Form IV. Form land Form III were shown to have a good physical stability at room temperature for 60 days. However, Form II is converted to Form III and Form IV is converted to Form I after 60 days storage. Therefore, these observations indicate that crystalline polymorphism for ketorolac is readily inter-convertible and the relationship may have to taken into consideration in the formulation of the drug.

Prepyrolysis Structural Relaxation of Coal Studied by Differential Scanning Calorimetry and Solvent Swelling

  • Yun, Yongseung;Suuberg, E.M.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.126-131
    • /
    • 1993
  • Differential Scanning Calorimetry (DSC) and solvent swelling technique have been applied for identifying physical transition temperatures in the macromolecular structure of coals. The transition processes seem to be associated with physical relaxation of the coal structure and are irreversible processes. In Pittsburgh No. 8 high volatile bituminous (hvb) coat one physical transition was noted at 250-30$0^{\circ}C$ (at 8$^{\circ}C$/min) without any significant accompanying weight loss. Coals of higher rank than high volatile bituminous, i.e., Upper Freeport medium volatile bituminous (mvb) and Pocahontas No.3 low volatile bituminous (lvb) coals, exhibit structural relaxation just before the major thermal decomposition process and a sharp increase in solvent swellability accompanies this relaxation. In the case of both the Pittsburgh No.8 and the Upper Freeport coat structural relaxations at around 36$0^{\circ}C$ seem to coincide with release of "guest molecules".les".uot;.

  • PDF

셀룰로오스의 열분해 반응속도론 (Kinetics on the Thermal Decomposition of Cellulose)

  • 최승찬;박영수
    • 한국연초학회지
    • /
    • 제5권2호
    • /
    • pp.55-62
    • /
    • 1983
  • Cellulose의 열분해 반응에 대한 Kinetic Parameter를 구하기 위하여 Thermogravimetry(TG)와 Differential Scanning Calorimetry(DSC)를 이용하는 네가지 비등온법을 고찰하였다. 그 결과 DSC에 의한 가열속도법과 TG에 의한 근사법이 가장 간편하였고Kinetic Parameters의 신뢰도도 매우 높았다. Cellulose 열분해 반응에서 반응차수는 1/2차였고 활성화에너지는 42kca1/mo1로 나타났다.

  • PDF

Consolidation 방법에 의해 제작된 유리섬유강화 복합재료의 결정성과 기계적성질에 관한 연구 (Crystallinity and Mechanical Properties of Glass Fiber Reinforced Thermoplastic Composites by Rapid Press Consolidation Technique)

  • 신익재;김동영;이동주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.91-96
    • /
    • 2000
  • Glass fiber reinforced thermoplastic composites were manufactured by Rapid Press Consolidation Technique(RPCT) as functions of temperature, pressure and time in pre-heating, consolidation and solidification sections during the manufacturing processing. It was found that the material property is greatly affected by pre-heating temperature under vacuum, mold temperature and molding pressure. Among them, the temperature In the mold was the most critical factor in determining the mechanical properties and the molded conditions of specimen. The crystallinity of PET matrix was also investigated by differential scanning calorimetry(DSC) measurements for various processing conditions. The level of crystallinity($X_c$) depended strongly on the mold temperature, cooling rate and the type of composite. The difference in $X_c$ is believed to be one of important factors in characterizing the mechanical properties.

  • PDF

The Morphology, Structure and Melting Behaviour of Cold Crystallized Isotactic Polystyrene

  • Marega, Carla;Causin, Valerio;Marigo, Antonio
    • Macromolecular Research
    • /
    • 제14권6호
    • /
    • pp.588-595
    • /
    • 2006
  • The morphology, structure and melting behaviour of cold-crystallized isotactic polystyrene (iPS) were studied by differential scanning calorimetry (DSC), wide angle X-ray diffraction (WAXD) and small angle X-ray scattering (SAXS). The polymer was found to crystallize according to the dual-lamellar stack model. The two populations of lamellae, along with a melting-recrystallization phenomenon, determined the appearance of multiple melting peaks in DSC traces. The annealing peak was attributed to the relaxation of a rigid amorphous phase, rather than to the melting of crystalline material.

A New Approach for Thermodynamic Study on the Binding of Human Serum Albumin with Cerium Chloride

  • Rezaei Behbehani, G.;Divsalar, A.;Saboury, A.A.;Faridbod, F.;Ganjali, M.R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1262-1266
    • /
    • 2009
  • Thermodynamics of the interaction between Cerium (III) chloride, $Ce^{3+}$, with Human Serum Albumin, HSA, was investigated at pH 7.0 and $27\;{^{\circ}C}$ in phosphate buffer by isothermal titration calorimetry. Our recently solvation model was used to reproduce the enthalpies of HSA interaction by $Ce^{3+}$. The solvation parameters recovered from our new model, attributed to the structural change of HSA and its biological activity. The interaction of HSA with $Ce^{3+}$ showed a set of two binding sites with negative cooperativity. $Ce^{3+}$ interacts with multiple sites on HSA affecting its biochemical and biophysical properties.

열경화성수지 복합재료의 경화정도의 측정에 관한 연구 (Measurement of the Degree of Cure of Thermosetting Resin Matrix Composite Materials)

  • 김진수;이대길
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2154-2164
    • /
    • 1995
  • In this study, a dielectric cure monitoring system which consists of an electric circuit, a sensor and a personal computer was developed to on-line monitor the dielectric properties of carbon fiber epoxy composite materials. Also, the kinetic model of carbon fiber epoxy composite materials was developed by curve fitting of differential scanning calorimetry data. The start and end points of cure and the relationship between the dissipation factor and the degree of cure were obtained by comparing the dissipation factor from the dielectric properties with the degree of cure from the DSC data. The relationship between the dissipation factor and the degree of cure was tested under various temperature profiles.

친수성 고분자와의 고체분산체로부터 질산펜티코나졸의 용출 증가 (Dissolution Enhancement of Fenticonazole Nitrate from Hydrophilic Polymer Solid Dispersions)

  • 김영일;김승인;최재윤
    • Journal of Pharmaceutical Investigation
    • /
    • 제19권2호
    • /
    • pp.109-116
    • /
    • 1989
  • Solid dispersion of fenticonazole nitrate (FN) with poloxamer 407, polyethylene glycol 6000, povidone (K-90) were prepared by the solvent method. To characterize the state of the drug in solid dispersions, the x-ray diffractometry and differential scanning calorimetry were carried out. The identification of these systems suggested that FN in the poloxamer 407 system remained in crystalline state, and the drug in the PVP system was amorphous. A marked increase in the dissolution rate of FN was attained by dispersing the drug in the hydrophilic polymers used, and the dispersion with poloxamer 407 was superior to the other two carriers in releasing the drug into solution.

  • PDF

고온초전도 케이블용 cryostat의 단열조건에 대한 열침입량 측정 (Experiment on Heat Loads Invaded into HTS Cable Cryostat under Cryogenic Insulation System)

  • 김도형;정원묵;김동락;양형석;조승연;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1564-1569
    • /
    • 2004
  • Insulating a heat from the environment is the most important in cryogenic applications like HTS cable system. Vacuum and MLI(Multi-Layer Insulation) have been widely used to get highly efficient cryogenic insulation. In this study, experiment on annular cylinder regarded as basic model of HTS cable cryostat has been performed to measure the heat loads. To investigate the effectiveness of radiation shields in cryogenic insulation system, the experiments are carried out to various number of the shields. The measured values are compared with the results estimated theoretically. The heat loads invaded from the environment was determined by liquid nitrogen boil-off calorimetry.

  • PDF

PCM의 잠열측정을 위한 T-history법에 대한 고찰 (Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials)

  • 박창현;최주환;홍희기
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF