• Title/Summary/Keyword: Caliper measurement

Search Result 55, Processing Time 0.026 seconds

Comparison of Caliper and Ultrasound Measurement for the Estimation of Body Fat (체지방량 추정을 위한 초음파피지후계와 Caliper의 비교)

  • 정진욱
    • Journal of Nutrition and Health
    • /
    • v.28 no.4
    • /
    • pp.282-290
    • /
    • 1995
  • Subcutaneous fat thickness of 74 young male was measured at six sites(biceps, triceps, subscapula, suprailiac, abdomen, thigh). The present study compared caliper with ultrasound measurements for the estimation of body fat. Caliper measurements subcutaneous at six sites had higher coefficient variation than did the ultrasound measures. Caliper measurements subcutaneous at six sites had higher ratio (caliper/ultrasound) than did the ultrasound measures. Compared to other body sites, the correlations between caliper and ultrasound measurements were high for the subscapula(r=0.7327), abdomen(r=0.7355) and thigh (r=0.7207) sites. the correlations between caliper and ultrasound measurements were high for the suprailiac(r=0.6616) site by lean group. the correlations between caliper and ultrasound measurements were high for the abdomen(r=0.7636) site by normal group. The correlations between caliper and ultrasound measurements were high for the subscapula (r=0.8959) and abdomen(r=0.8237) sites by obese group. Ultrasound measurement of biceps(r=-0.4459), abdomen9r=-0.4469), thigh(r=-0.4348) had the highest correlation with body density. Caliper measurement of triceps(r=-0.4017), subscapula(r=-0.4454), abdomen(r=-0.4293) had the highest correlation with body density. Ultasound measurements subcutaneous fat at lean group, obese group had higher coefficients of correlation with body density than did the caliper measurement. Caliper measurements subcutaneous fat at normal group had higher coefficients of correlation with body density than did the ultrasound measures. Ultrasound showed to be superior to the caliper technique in measuring subcutaneous fat of obese persons.

  • PDF

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

Body composition and measurement of subcutaneous fat thickness by ultrasonic method (초음파법에 의한 피하지방두께의 측정과 신체조성)

  • 성수광;장수정
    • Journal of the Ergonomics Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.47-58
    • /
    • 1994
  • The purpose of this study was to obtain the basic data for a design for comfort wear. The subjects of this study were 197 women's university stu- dents. The characteristics of their body types and the thickness of subcuta- neous fat at eight body sites were measured. The thickness of subcutaneous fat was measured by both Ultrasonics and with a Skinfold Caliper. The cor- relation between their values and the thickness of subcutaneous fat were compared. The relationship between Rohrer Index and the subject's self- conception of their body was also compared. The results were as follows: 1. The measurement of thickness of subcutaneous fat at triceps and scapula was a little lower, in using Skinfold Caliper method, than Ultrasonics method because of the pressure of the caliper. 2. Correlation between percentage of fat in body and body characteristics was high in order of chest girth > weight > abdomen girth. 3. The thickness of subcutaneous 8 body these sites was high in order of thigh > triceps > scapula > abdomen > suprailiac > chest > calf > forearm. Percentage of body fat has a positive correlation with both average thickness of subcutaneous fat and thickness of subcutaneous fat at triceps. 4. Rohrer Index shows a positive correlation between average thickness of subcutaneous fat and percentage of body fat. 5. About half of subjects of this study thought that they were obese although the data proved otherwise.

  • PDF

Fatigue Damage Analysis of the Caliper Housing under ABS Mode (ABS 작동에 의한 캘리퍼하우징에 미치는 피로손상평가)

  • 김정엽;모종운
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.156-163
    • /
    • 1996
  • The brakes are the most important safety-critical accident avoidance components of a motor vehicle. They must perform safely under a variety of operating conditions and must have enough strength not to fail during the life of a vehicle. Recently, anti-lock brake systems are used on more and more passenger cars. The ABS brakes modulate brake line pressure to prevent brakes from locking during braking. In this study, finite element analysis, material test for FCD45, measurement of stress and cumulative fatigue damage analysis were performed to evaluate fatigue damage of the caliper housing under ABS mode.

  • PDF

Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition

  • Seo Young Shin;Yong Kwon Chae;Ko Eun Lee;Mi Sun Kim;Ok Hyung Nam;Hyo-seol Lee;Sung Chul Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.55-65
    • /
    • 2024
  • This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

Design and Implementation of 30" Geometry PIG

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.629-636
    • /
    • 2003
  • This paper introduces the developed geometry PIG (Pipeline Inspection Gauge), one of several ILI (In-Line Inspection) tools, which provide a full picture of the pipeline from only single pass, and has compact size of the electronic device with not only low power consumption but also rapid response of sensors such as calipers, IMU and odometer. This tool is equipped with the several sensor systems. Caliper sensors measure the pipeline internal diameter, ovality and dent size and shape with high accuracy. The IMU (Inertial Measurement Unit) measures the precise trajectory of the PIG during its traverse of the pipeline. The IMU also provide three-dimensional coordination in space from measurement of inertial acceleration and angular rate. Three odometers mounted on the PIG body provide the distance moved along the line and instantaneous velocity during the PIG run. The datum measured by the sensor systems are stored in on-board solid state memory and magnetic tape devices. There is an electromagnetic transmitter at the back end of the tool, the transmitter enables the inspection operators to keep tracking the tool while it travels through the pipeline. An experiment was fulfilled in pull-rig facility and was adopted from Incheon LT (LNG Terminal) to Namdong GS (Governor Station) line, 13 km length.

Quantitative measurement of peri-implant bone defects using optical coherence tomography

  • Kim, Sulhee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Bome;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.84-91
    • /
    • 2018
  • Purpose: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. Methods: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. Results: The average defect depth measured by a digital caliper was $4.88{\pm}1.28mm$, and the corresponding OCT measurement was $5.11{\pm}1.33mm$. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. Conclusions: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.

A Preliminary Study on the Determining Indicatory Factors for Frenulotomy: Maximum Lingual Length-Protrusion of 3-6 Year Old Normal Children with Boley Gauge (Digimatic Caliper$Caliper^{(R)}$) (설소대 절단술의 결정 요인에 관한 기초 연구: Boley gauge를 이용한 3$\sim$6세 정상 아동의 혀의 최대 신장 길이 계측)

  • Choi, Jae-Nam;Pyo, Hwa-Young;Sim, Hyun-Sub;Choi, Hong-Shik
    • Speech Sciences
    • /
    • v.8 no.3
    • /
    • pp.161-172
    • /
    • 2001
  • Ankyloglossia (tongue-tie) limits movement of the tongue connected with feeding and has adverse impacts on both dental health and speech. For the patients with ankyloglossia, surgical intervention is recommended as primary treatment. This study suggests the efficient tool in determining indicatory factors for frenulotomy by quantifying Maximum Lingual Length-Protrusion (MLL-P) with boley gauge, and as a preliminary study, to show the measurement results with normal children using the tool. The subjects were 61 normal children, and the distance (MLL-P) between mandibular central incisor and tongue tip during tongue protrusion was measured with a boley gauge (Digimatic $Caliper^{(R)}$). The results of this study can be summarized as follows: (1) The mean value of MLL-P (N=61 normal children) was 21.44 mm, (2) The mean value of MLL-P was 20.69 mm in males (N=33) and 21.91 mm in females (N=28). There was no statistically significant difference between males and females, (3) The mean value of MLL-P was 19.34 mm, 21.19 mm, 22.33 mm, 22.61 mm for measurement of 3-, 4-, 5- and 6-year-old children, respectively, and (4) The mean value of MLL-P showed statistically significant difference between 3- and 5-year-old children, between 3- and 6-year old children.

  • PDF

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.

A Study on the Development of the Automatic Performance-Test-Bench for Drag Torque (드래그 토오크의 자동 성능시험기 개발에 관한 연구)

  • Lee, Seong-Ho;Mok, Hak-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.166-174
    • /
    • 2008
  • Recently, the automotive industry has been developing rapidly. With the progress parts of the automobile components need high quality and the reliability. Among them, braking unit is essential device, and acquire the reliability through the performance test of brake. This study was aimed to design the performance-test-bench to measure the drag torque which has effect on caliper in braking unit. In this progressive technology, it is vital importance to use hydraulic and pneumatic, and to combine test bench with instrumentation engineering technology. This system to construct the design of hydraulic and pneumatic circuit, interface technique between sensors and personal computer, data acquisition and display design, and integrated control are very important technology. Moreover, reliable data are obtained through vacuum system and hydraulic and pneumatic system by using of booster and brake master cylinder which are actually applied to automobile. Then, data signal detector sensors for speed, pressure and torque is attached on this system. Therefore, in this study, we designed a performance-test-bench by and we also made an total control system using personal computer which is more progressive and flexible method than existing PLC control.