• 제목/요약/키워드: Calibration method

검색결과 2,822건 처리시간 0.028초

신경 회로망을 이용한 로봇의 상대 오차 보상 (Relative Error Compensation of Robot Using Neural Network)

  • 김연훈;정재원;김수현;곽윤근
    • 한국정밀공학회지
    • /
    • 제16권7호
    • /
    • pp.66-72
    • /
    • 1999
  • Robot calibration is very important to improve the accuracy of robot manipulators. However, the calibration procedure is very time consuming and laborious work for users. In this paper, we propose a method of relative error compensation to make the calibration procedure easier. The method is completed by a Pi-Sigma network architecture which has sufficient capability to approximate the relative relationship between the accuracy compensations and robot configurations while maintaining an efficient network learning ability. By experiment of 4-DOF SCARA robot, KIRO-3, it is shown that both the error of joint angles and the positioning error of end effector are drop to 15$\%$. These results are similar to those of other calibration methods, but the number of measurement is remarkably decreased by the suggested compensation method.

  • PDF

Development of standard calibration equipment for the rain gauges

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2468-2473
    • /
    • 2005
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the error for the rainfall intensity and obtained useful result through the proposed calibration method.

  • PDF

Advanced On-chip SOL Calibration Method for Unknown Fixture De-embedding

  • Yoon, Changwook;Chen, Bichen;Ye, Xiaoning;Fan, Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권4호
    • /
    • pp.543-551
    • /
    • 2017
  • SOL (Short, Open and Load) calibration based on iterative error sensitivity is proposed in this paper. With advanced SOL calibration, unknown parasitic parameters at on-chip terminations are accurately estimated up to 20 GHz. Artificial terminations are designed on printed circuit board (PCB) to experiment the proposed method. On-chip SHORT, OPEN and LOAD fabricated inside silicon shows the accuracy of proposed calibration method through the comparison with known fixture S-parameter after de-embedding.

중계기가 연결된 빔포밍 기지국을 위한 새로운 RF-패스 보정절차 방법 (A New RF-path Calibration Method for BSs with Repeaters)

  • 김성만
    • 한국전자통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.274-279
    • /
    • 2011
  • 이동통신 시스템의 성능을 증가시키기 위해서 다중안테나 기술 중의 하나인 빔포밍(beamforming) 기술을 적용하고자 하는 노력들이 많이 이루어지고 있다. 이러한 빔포밍 기능을 수행하기 위해서는 여러 RF 안테나 패스간의 위상 및 진폭차를 주기적으로 보정해 주는 절차가 필요한데, 이를 RF-패스 보정절차(calibration) 라고 한다. 하지만, 현재 Mobile WiMAX 기지국에서 사용되고 있는 RF-패스 보정 방법은 중계기가 연결될 때에 문제가 발생될 수 있다. 본 논문에서는 이러한 문제점을 기술하고 이를 해결하기 위한 새로운 보정절차 방법을 제시한다.

새로운 선형의 외형적 카메라 보정 기법 (A New Linear Explicit Camera Calibration Method)

  • 도용태
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.66-71
    • /
    • 2014
  • Vision is the most important sensing capability for both men and sensory smart machines, such as intelligent robots. Sensed real 3D world and its 2D camera image can be related mathematically by a process called camera calibration. In this paper, we present a novel linear solution of camera calibration. Unlike most existing linear calibration methods, the proposed technique of this paper can identify camera parameters explicitly. Through the step-by-step procedure of the proposed method, the real physical elements of the perspective projection transformation matrix between 3D points and the corresponding 2D image points can be identified. This explicit solution will be useful for many practical 3D sensing applications including robotics. We verified the proposed method by using various cameras of different conditions.

유동속도계측을 위한 5공압력프로브의 새로운 교정 알고리듬 (A New Calibration Algorithm of a Five-Hole Pressure Probe for Flow Velocity Measurement)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.18-25
    • /
    • 2008
  • This paper investigated the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new data reduction method Includes a look-up, a geometry transformation such as the translation and reflection of nodes, and a binary search algorithm. This new calibration map was applied up to the application angle, ${\pm}55^{\circ}$ of a probe. As a result, this data reduction method showed a perfect performance without any kind of interpolation errors In calculating yaw and pitch angle from the calibration map.

  • PDF

비영위법에 의한 5공 프로브의 교정에 관한 연구 (A Study on the Five - hole Probe Calibration with Non-nulling Method)

  • 정양범;신영호;박호동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.116-116
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw and total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

비영위법에 의한 5공 프로브의 교정에 관한 연구 (A Study on the Five-hole Probe Calibration with Non-nulling Method)

  • 정양범;신영호;박호동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.48-56
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw abd total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.

  • PDF

A sample size calibration approach for the p-value problem in huge samples

  • Park, Yousung;Jeon, Saebom;Kwon, Tae Yeon
    • Communications for Statistical Applications and Methods
    • /
    • 제25권5호
    • /
    • pp.545-557
    • /
    • 2018
  • The inclusion of covariates in the model often affects not only the estimates of meaningful variables of interest but also its statistical significance. Such gap between statistical and subject-matter significance is a critical issue in huge sample studies. A popular huge sample study, the sample cohort data from Korean National Health Insurance Service, showed such gap of significance in the inference for the effect of obesity on cause of mortality, requiring careful consideration. In this regard, this paper proposes a sample size calibration method based on a Monte Carlo t (or z)-test approach without Monte Carlo simulation, and also proposes a test procedure for subject-matter significance using this calibration method in order to complement the deflated p-value in the huge sample size. Our calibration method shows no subject-matter significance of the obesity paradox regardless of race, sex, and age groups, unlike traditional statistical suggestions based on p-values.

A Calibration Method for Six-Accelerometer INS

  • Hung Chao-Yu;Lee Sou-Chen
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권5호
    • /
    • pp.615-623
    • /
    • 2006
  • The gyroscope free strap-down INS is composed only of accelerometers. Any gyroscope free INS navigation error is deeply affected by the accuracy of the sensor bias, scale factor, orientation and location error. However these parameters can be found by calibration. There is an important research issue about a multi-position calibration method in this paper. It provides a novel method to find the error parameters for the six-accelerometer INS. A superior simulation is shown that the multi-position calibration can find the specifications of a six-accelerometer INS in laboratory. From these parameters the six-accelerometer INS could apply in realistic navigation.