• Title/Summary/Keyword: Calibration matrix

Search Result 256, Processing Time 0.024 seconds

Method Development for the Profiling Analysis of Urine Globotriaosylceramide (Gb3) for the Screening of Fabry Disease by Tandem Mass Spectrometry (ESI-MS/MS를 이용한 소변 중 Globotriaosylceramide(Gb3)의 정량 및 임상 응용; 패브리병(Fabry) 진단)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Kang, Seung-Woo;Kwon, Young-Joo;Jeong, Choon-Sik;Lee, Yong-Soo
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.96-102
    • /
    • 2007
  • Measurement of globotriaosylceramide (Gb3, ceramide trihexoside) in urine has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. A simple, rapid, and highly sensitive analytical method for Gb3 in urine was developed without labor-extensive pre-treatment by electrospray ionization MS/MS (ESI-MS/MS). Only simple 5-fold dilution of urine is necessary for the extraction and isolation of Gb3 in urine. Gb3 in diluted urine was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Eight isoforms of Gb3 were completely resolved from urine matrix. C24:0 Gb3 occupied 50% of total Gb3 as a major component in urine. Linear relationship for Gb3 isoforms was found in the range of 0.005${\sim}$5.0 ${\mu}$g/ml. The limit of detection (S/N=5) was 0.005 ${\mu}$g/ml and limit of quantification was 0.05 ${\mu}$g/ml for C24:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9598 to 0.9975. This method could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

Stereo Vision based on Planar Algebraic Curves (평면대수곡선을 기반으로 한 스테레오 비젼)

  • Ahn, Min-Ho;Lee, Chung-Nim
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.1
    • /
    • pp.50-61
    • /
    • 2000
  • Recently the stereo vision based on conics has received much attention by many authors. Conics have many features such as their matrix expression, efficient correspondence checking, abundance of conical shapes in real world. Extensions to higher algebraic curves met with limited success. Although irreducible algebraic curves are rather rare in the real world, lines and conics are abundant whose products provide good examples of higher algebraic curves. We consider plane algebraic curves of an arbitrary degree $n{\geq}2$ with a fully calibrated stereo system. We present closed form solutions to both correspondence and reconstruction problems. Let $f_1,\;f_2,\;{\pi}$ be image curves and plane and $VC_P(g)$ the cone with generator (plane) curve g and vertex P. Then the relation $VC_{O1}(f_1)\;=\;VC_{O1}(VC_{O2}(f_2)\;∩\;{\pi})$ gives polynomial equations in the coefficient $d_1,\;d_2,\;d_3$ of the plane ${\pi}$. After some manipulations, we get an extremely simple polynomial equation in a single variable whose unique real positive root plays the key role. It is then followed by evaluating $O(n^2)$ polynomials of a single variable at the root. It is in contrast to the past works which usually involve a simultaneous system of multivariate polynomial equations. We checked our algorithm using synthetic as well as real world images.

  • PDF

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.

Development and Validation of an Analytical Method for β-Agonists in Livestock and Fishery Products Using LC-MS/MS (LC-MS/MS를 이용한 축·수산물 중 β-agonist계 시험법 개발 및 검증)

  • Lee, Tae Ho;Kim, Yu Ra;Park, Su Jeong;Kim, Ji Young;Choi, Jang Duck;Moon, Gui Im
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.2
    • /
    • pp.135-151
    • /
    • 2022
  • BACKGROUND: The β-agonists known as phenyl ethanolamine derivatives have a conjugated aromatic ring with amino group. They are used as tocolytic agents and bronchodilator to human and animal generally, and some of them are used as growth promoters to livestock. METHODS AND RESULTS: β-agonists in samples were extracted by 0.4 N perchloric acid and ethyl acetate. The target compounds were analyzed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS). Validation of method was performed according to CODEX guidelines (CAC/GL-71). The matrix matched calibration gave correlation coefficients>0.98, and the obtained recoveries were in the range of 62.0-109.8%, with relative standard deviation ≤ 20.1%. In addition, a survey was performed to inspect any residual β-agonist from 100 samples of livestock and fishery products and ractopamine was detected in one of the 100 samples. CONCLUSION(S): In this study, we established the analytical method for β-agonists through using the expanded target compounds and samples. And we anticipate that the established method would be used for analysis to determine veterinary drug residues in livestock and fishery products.

Development of the Simultaneous Analysis of 36 Sulfonylurea Herbicide Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 제초제 Sulfonylurea계 36종 동시 시험법 개발)

  • Su Jung Lee;Jung Mi Lee;Gui Hyun Jang;Hyun-Kyung Kim;Ji Young Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.2
    • /
    • pp.139-151
    • /
    • 2023
  • Sulfonylurea herbicides are widely used in agriculture because they have a long residual period and high selectivity. An analytical method was developed using QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) technique for simultaneous determination of sulfonylurea herbicide residues in agricultural products by liquid chromatography tandem mass spectrometry and for establishment MRL (Maximum Residue Limit) of those herbicides in Korea. Extraction was performed using acetonitrile containing 0.1% formic acid with MgSO4 (anhydrous magnesium sulfate) and NaCl (sodium chloride) and the extract was cleaned up using MgSO4 and C18 (octadecyl). The matrix-matched calibration curves were composed of 7 concentration levels from 0.001 to 0.25 mg/kg and their coefficients of determination (R2) exceeded 0.99. The recoveries of three spiking levels (LOQ, 10LOQ, 50LOQ, n=5) were in the range of 71.7-114.9% with relative standard deviations of less than 20.0% for all the five agriculture products. All validation values met criteria of the European Union SANTE/11312/2021 guidelines and Food and Drug Safety Evaluation guidelines. Therefore, the proposed analytical method was accurate, effective, and sensitive for sulfonylurea herbicide residues determination in agricultural commodities.

Heterogeneous Sensor Coordinate System Calibration Technique for AR Whole Body Interaction (AR 전신 상호작용을 위한 이종 센서 간 좌표계 보정 기법)

  • Hangkee Kim;Daehwan Kim;Dongchun Lee;Kisuk Lee;Nakhoon Baek
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.7
    • /
    • pp.315-324
    • /
    • 2023
  • A simple and accurate whole body rehabilitation interaction technology using immersive digital content is needed for elderly patients with steadily increasing age-related diseases. In this study, we introduce whole-body interaction technology using HoloLens and Kinect for this purpose. To achieve this, we propose three coordinate transformation methods: mesh feature point-based transformation, AR marker-based transformation, and body recognition-based transformation. The mesh feature point-based transformation aligns the coordinate system by designating three feature points on the spatial mesh and using a transform matrix. This method requires manual work and has lower usability, but has relatively high accuracy of 8.5mm. The AR marker-based method uses AR and QR markers recognized by HoloLens and Kinect simultaneously to achieve a compliant accuracy of 11.2mm. The body recognition-based transformation aligns the coordinate system by using the position of the head or HMD recognized by both devices and the position of both hands or controllers. This method has lower accuracy, but does not require additional tools or manual work, making it more user-friendly. Additionally, we reduced the error by more than 10% using RANSAC as a post-processing technique. These three methods can be selectively applied depending on the usability and accuracy required for the content. In this study, we validated this technology by applying it to the "Thunder Punch" and rehabilitation therapy content.

Development of Simultaneous Analysis for Multiple Agricultural Pesticides in Raw Milk Products using GC-MS/MS (GC-MS/MS를 이용한 원유 원료 중 농약 동시분석법 확립)

  • Young Nae Choi;Yoon ho Shin;Hwangeui Cho;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.420-429
    • /
    • 2023
  • GC-MS/MS using liquid-liquid extraction (LLE) and C18 cartridges was used to identify and quantify levels of chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin and permethrin in bulk raw milk. A calibration curve spanning 10 ng/mL to 200 ng/mL was obtained with a satisfactory correlation coefficient of 0.99. The limits of detection (LOD) and limits of quantitation (LOQ) for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in the matrix ranged from 0.06 to 1.81 ng/mL and 0.19 to 6.04 ng/mL, respectively. The recoveries of 5 pesticides from spiked samples at 37.5-125 ng/mL ranged from 86.1 to 102.1%. The measurement of uncertainty of the GC-MS/MS method for these five pesticides was developed based on the analytical process and quantification. An analysis method that is easier and faster than the method specified in the Korean food standards codes for analyzing these five pesticides in raw material milk was developed. Moreover, the analytical method for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in bulk raw milk by GC-MS/MS was established.

Performance Analysis of the Array Shape Estimation Methods Based on the Nearfield Signal Modeling (근거리 신호 모델링을 기반으로 한 어레이 형상 추정 기법들의 성능 분석)

  • Park, Hee-Young;Lee, Chung-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.221-228
    • /
    • 2008
  • To estimate array shape with reference sources in SONAR systems, nearfield signal modeling is required for the reference sources near a towed array. Array shape estimation method based on the nearfield signal modeling generally exploits the spatial covariance matrix of the received reference sources. Among those method, nearfield eigenvector method uses the eigenvector corresponding to the maximum eigenvalue as a steering vector of the reference source. In this paper, we propose a simplified subspace fitting method based on the nearfield signal modeling with spherical wave modeling. Furthermore, we analyze performance of the array shape estimation methods based on the nearfield signal modeling for various environments. The results of the numerical experiments indicate that the simplified subspace fitting method and the nearfield eigenvector method with single reference source shows almost similar performance. Furthermore, the simplified subspace fitting method with 2 reference sources consistently estimates the shape of the array regardless of the incident angle of the reference sources, whereas the nearfield eigenvector method cannot apply for the case of 2 reference sources.

Analysis of Systemic Pesticide Imidacloprid and Its Metabolites in Pepper using QuEChERS and LC-MS/MS (QuEChERS 전처리와 LC-MS/MS를 이용한 고추 중 침투성농약 Imidacloprid 및 대사물질 동시분석법)

  • Seo, Eun-Kyung;Kim, Taek-Kyum;Hong, Su-Myeong;Kwon, Hye-Yong;Kwon, Ji-Hyung;Son, Kyung-Ae;Kim, Jang-Eok;Kim, Doo-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.264-270
    • /
    • 2013
  • Imidacloprid is a systemic insecticide which act as an insect neurotoxin. It used for control of pest such as aphids and other sucking insects in fruits and vegetables. Systemic pesticides move inside a crop following absorption by the plant, and these were converted into a variety of metabolites. Sometimes these metabolites make a problem about safety of agricultural products. So a simultaneous determination method of pesticide and its metabolites is needed, to monitor their presence in agricultural product and study on the fate of pesticide in a plant. This study's aim is to investigate simultaneous analysis method of imidacloprid and its metabolites, imidacloprid guanidine, imidacloprid olefin, imidacloprid urea, and 6-chloronicotinic acid in red pepper using QuEChERS method and LC-MS/MS systems. QuEChERS method was modifed beacuase $MgSO_4$ salts decreased the recoveries of 6-chloronicotinic acid in extraction procedure. Imidacloprid and its metabolites were extracted by acetonitrile with 1% glacial acetic acid and the extracts were purified through QuEChERS with primary secondary amine (PSA) and $C_{18}$ and analyzed with LC-MS/MS in ESI positive mode. Standard calibration curves were made by matrix matched standards and their correlation coefficients were higher than 0.999. Recovery studies were carried out on spiked pepper blank sample at four concentration levels (0.01, 0.04 and 0.1, 0.4 mg/kg). The average recoveries of imidacloprid and its metabolites were in the range of 70~120% with < 20% RSD. This result indicated that the method using QuEChERS and LC-MS/MS was suitable for the simultaneous determination of imidacloprid and its metabolites in red pepper.

Monitoring of Pesticides in the Yeongsan and Seomjin River Basin (영산강 및 섬진강 수계 중 농약 분포 조사)

  • Lee, Young-Jun;Choi, Jeong-Heui;Kim, Sang Don;Jung, Hee-Jung;Lee, Hyung-Jin;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • BACKGROUND: A lasting release of low levels of persistence chemicals including pesticides and pharmaceuticals into river has a bad influence on aquatic ecosystems and humans. The present study monitored pesticide residues in the Yeongsan and Seomjin river basins and their tributaries as a fundamental study for water quality standard of pesticides.METHODS AND RESULTS: Nine pesticides(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, and molinate) were determined from water samples using SPE-Oasis HLB(pH 2) and LC/MS/MS. Validation of the method was conducted through matrix-matched internal calibration curve, method detection limit(MDL), limit of quantification(LOQ), accuracy, precision, and recovery. MDLs of all pesticides satisfied the GV/10 values. Linearity(r2) was 0.9965- 0.9999, and a percentage of accuracy, precision, and recovery was 89.4-113.6%, 3.1-14.0%, and 90.8-106.2%, respectively. All pesticides exclusive of aldicarb were determined in the river samples, and there was a connection between the positive monitoring results and agricultural use of the pesticides.CONCLUSION: Monitoring outcomes of the present study implied that pesticides were a possible non-point pollutant source in the Yeongsan and Seomjin river basins and tributaries. Therefore, it is required to produce and accumulate more monitoring results on pesticides in river waters to set water quality standards, finally to preserve aquatic ecosystems.