• 제목/요약/키워드: Calibration and validation

검색결과 657건 처리시간 0.034초

Nondestructive Prediction of Fatty Acid Composition in Sesame Seeds by Near Infrared Reflectance Spectroscopy

  • Kim, Kwan-Su;Park, Si-Hyung;Choung, Myoung-Gun;Kim, Sun-Lim
    • 한국작물학회지
    • /
    • 제51권spc1호
    • /
    • pp.304-309
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) was used to develop a rapid and nondestructive method for the determination of fatty acid composition in sesame (Sesamum indicum L.) seed oil. A total of ninety-three samples of intact seeds were scanned in the reflectance mode of a scanning monochromator, and reference values for fatty acid composition were measured by gas-liquid chromatography. Calibration equations were developed using modified partial least square regression with internal cross validation (n=63). The equations obtained had low standard errors of cross-validation and moderate $R^2$ (coefficient of determination in calibration). Prediction of an external validation set (n=30) showed significant correlation between reference values and NIRS estimated values based on the SEP (standard error of prediction), $r^2$ (coefficient of determination in prediction) and the ratio of standard deviation (SD) of reference data to SEP. The models developed in this study had relatively higher values (more than 2.0) of SD/SEP(C) for oleic and linoleic acid, having good correlation between reference and NIRS estimate. The results indicated that NIRS, a nondestructive screening method could be used to rapidly determine fatty acid composition in sesame seeds in the breeding programs for high quality sesame oil.

근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구 (A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy)

  • 윤성운;마상동;김명윤;김재열
    • 한국공작기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

다변량 분석법을 이용한 Tryptophan과 Tyrosine의 형광분광법적 정량 (Simultaneous Determination of Tryptophan and Tyrosine by Spectrofluorimetry Using Multivariate Calibration Method)

  • 이상학;박주은;손범목
    • 대한화학회지
    • /
    • 제46권4호
    • /
    • pp.309-317
    • /
    • 2002
  • 형광분광법에 의하여 주성분 회귀분석(principal component regression, PCR)과 부분 최소자승법(Partial least squares, PLS)을 이용하여 아미노산(Tryptophan and Tyrosine)을 동시에 정량하는 방법에 대하여 연구하였다. 아미노산 혼합물의 형광 스펙트럼은 들뜸파장을257nm로 고정하여 측정하였다. 두 가지 아미노산이 서로 다른 농도로 혼합되어 있는 32개의 시료용액을 280nm∼500nm 범위에서 스펙트럼들을 얻었고 이를 이용하여 PCR과 PLS회귀모델을 얻었다. 두 가지 아미노산이 서로 다른 농도로 포함된 6개의 외부검정용 시료들의 스펙트럼들을 이용해서 회귀모델의 적합성을 검정하기 위하여 외부검정용 시료의 농도를 계산하였다. 계산된 농도를 이용하여 relative standard error of prediction($RSEP_a$)를 얻었고 같은 방법으로 overall relative standard error of prediction($RSEP_m$) 도 구하였다

보스턴 넷폰셋강의 수질체계에 대한 스왓모델의 교정과 유효성 검증 (Calibration and Validation of SWAT for the Neponset River Watershed in Boston)

  • 이자원
    • 한국지역지리학회지
    • /
    • 제14권1호
    • /
    • pp.19-26
    • /
    • 2008
  • SWAT 기법은 자연지형을 기반으로 수질관련 현상을 지속적으로 분석하고 예측하며 복합적인 수질 체계를 연구하는데 널리 쓰여왔다. 이는 기후와 관련된 온도, 강수량을 주 데이터로 소규모 지역단위부터 광범위한 지표면의 수질 체계를 토양, 토지이용 행태, 그리고 경사면의 정도와 연계시켜 지역적 토양과 수질의 특성을 파악한다. 모든 자료는 일간으로 구성되며 첫 일정 연도는 데이터의 셋업과정으로 분석이 되고 중간의 일정 연도는 변화정도를 파악하는 기간으로 활용이되며, 마지막 일정연도는 검증과정으로 분석이 된다. SWAT 기법은 수질오염은 물론, 지표면의 오염형태를 파악함으로써 농업활동의 분석과 연구에 도움을 주고, 도시에서 배출되는 오염원의 유형과 그것이 주변지역에 미치는 영향을 도출해 내어 지역 환경개발에 유익한 모델 기법이다. 지역적인 수질 환경을 모델화시키기 위하여 수치의 교정과정이 필요하고 지속적인 연구로 활용하기 위하여 어떠한 인자가 가장 민감하게 반응하는 가에 관한 차후 분석이 뒤따르고 있으며, 결과화된 수치의 유효성 검증이 중요시되고 있다. SWAT 2005 버전은 ArcView 3.3과 ArcGis9.1에서 공간분석이 가능하다.

  • PDF

수중탐상로봇시스템의 오차분석 및 보정 (Calibration of an underwater robotic inspection system)

  • 장종훈;김재열;김재희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.378-378
    • /
    • 2000
  • The permissible positioning error of the transducer used in reactor inspection must be within 10 mm. To implement the required precision it is necessary to manufacture all components affecting the positioning mechanism correctly and precisely. In addition, it is also necessary to handle error factors accurately. This paper describes the activities of the findings and corrections of the errors which were occurred in experiments. Those activities are; i) Categorization of error factors, ii) Cause analysis of errors, iii) Correction of errors founded in experiments by the analysis of laser induction type and by the validation of real measurement of horizontal, vertical baselines.

  • PDF

ASSESSING CALIBRATION ROBUSTNESS FOR INTACT FRUIT

  • Guthrie, John A.;Walsh, Kerry B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1154-1154
    • /
    • 2001
  • Near infra-red (NIR) spectroscopy has been used for the non-invasive assessment of intact fruit for eating quality attributes such as total soluble solids (TSS) content. However, little information is available in the literature with respect to the robustness of such calibration models validated against independent populations (however, see Peiris et al. 1998 and Guthrie et al. 1998). Many studies report ‘prediction’ statistics in which the calibration and prediction sets are subsets of the same population (e. g. a three year calibration validated against a set from the same population, Peiris et al. 1998; calibration and validation subsets of the same initial population, Guthrie and Walsh 1997 and McGlone and Kawano 1998). In this study, a calibration was developed across 84 melon fruit (R$^2$= 0.86$^{\circ}$Brix, SECV = 0.38$^{\circ}$Brix), which predicted well on fruit excluded from the calibration set but taken from the same population (n = 24, SEP = 0.38$^{\circ}$Brix with 0.1$^{\circ}$Brix bias), relative to an independent group (same variety and farm but different harvest date) (n = 24, SEP= 0.66$^{\circ}$ Brix with 0.1$^{\circ}$Brix bias). Prediction on a different variety, different growing district and time was worse (n = 24, SEP = 1.2$^{\circ}$Brix with 0.9$^{\circ}$Brix bias). Using an ‘in-line’ unit based on a silicon diode array spectrometer, as described in Walsh et al. (2000), we collected spectra from fruit populations covering different varieties, growing districts and time. The calibration procedure was optimized in terms of spectral window, derivative function and scatter correction. Performance of a calibration across new populations of fruit (different varieties, growing districts and harvest date) is reported. Various calibration sample selection techniques (primarily based on Mahalanobis distances), were trialled to structure the calibration population to improve robustness of prediction on independent sets. Optimization of calibration population structure (using the ISI protocols of neighbourhood and global distances) resulted in the elimination of over 50% of the initial data set. The use of the ISI Local Calibration routine was also investigated.

  • PDF

근적외선분광(NIRS)을 이용한 참깨의 lignan 함량 비파괴 분석 방법 확립 (Establishment of a Nondestructive Analysis Method for Lignan Content in Sesame using Near Infrared Reflectance Spectroscopy)

  • 이정은;김성업;이명희;김정인;오은영;김상우;김민영;박재은;조광수;오기원
    • 한국작물학회지
    • /
    • 제67권1호
    • /
    • pp.61-66
    • /
    • 2022
  • 본 연구는 참깨에 함유된 세사민 및 세사몰린의 함량을 비파괴적으로 신속하게 평가하기 위하여 NIRS 분석을 이용해 검량식을 작성하고 검량식의 적용가능성을 검증하였다. 검량식 작성에 사용된 482점 참깨의 HPLC 분석 결과를 NIRS 스펙트럼에 적용시킨 후 검량식을 작성하였다. 세사민 및 세사몰린의 R2 값은 각각 0.936, 0.875로 조사되었으며 이를 cross validation 한 결과에서도 각각 0.899, 0.781로 조사되어 리그난 함량 분석에 적용 가능할 것으로 판단되었다. 작성된 검량식의 적용가능성을 확인하기 위해 2020년에 생산된 참깨 유전자원 90종의 종자를 NIRS를 통해 분석한 결과 세사민 및 세사몰린의 R2값이 각각 0.653, 0.596으로 크게 낮아졌으나 리그난 함량이 높은 상위 30%의 자원을 선발하는데 무리가 없었다. 따라서 본 연구에서 작성된 NIRS 검량식은 육종 초기에 고리그난 함량을 선발하는데 적용 가능할 것으로 판단된다.

근적외분광분석기를 이용한 검정콩 안토시아닌의 함량 분석 (Development of Prediction Model by NIRS for Anthocyanin Contents in Black Colored Soybean)

  • 김용호;안형균;이은섭;김희동
    • 한국작물학회지
    • /
    • 제53권1호
    • /
    • pp.15-20
    • /
    • 2008
  • 검정콩 종피에 함유된 안토시아닌의 색소별 함량을 비파괴적으로 신속하게 분석하기 위하여 NIRS(근적외선 분광분석기)를 이용한 모델을 개발하였다. 재료는 검정콩 유전자원 300 계통을 사용하였으며, HPLC에서 분석된 종피의 안토시아닌 함량치를 NIRS 스펙트럼에 적용시킨 후 검량식을 작성하였다. NIRS의 검량식을 몇 가지 방법에 의하여 비교 분석한 결과 1차미분된 스펙트럼을 MPLS(Modified Partial Least Squares)를 이용한 회귀식에 이용하는 것이 가장 적합하였다. HPLC를 이용한 유전자원들의 성분 함량과 NIRS에서 도출된 검량식과의 상관계수는 C3G, D3G 및 Pt3G가 각각 0.952, 0.936과 0.833을 나타내었다. 이들 검량식은 validation file에서도 C3G와 D3G는 0.897, 0.849의 높은 상관을 보였으며, 이는 NIRS를 이용하여 검정콩의 안토시아닌 함량을 신속하게 분석할 수 있음을 나타내는 것으로 판단되었다.

지구관측용 마이크로파 위성센서의 검보정 연구 동향 (Research Trend of Calibration Methods on the Satellite Microwave Sensors)

  • 진경욱;양군호
    • 항공우주산업기술동향
    • /
    • 제8권1호
    • /
    • pp.33-44
    • /
    • 2010
  • 이 논문에서는 지구관측용 위성에 장착된 마이크로파 센서들의 검보정법에 대해 조사, 기술하였다. 아울러 현재 운영 중이거나 이러한 미션들을 대체하여 향후 진행될 대표적인 지구관측 미션들을 소개하였다. 보다 효과적인 이해를 위해 지구 관측 미션들을 중심으로 이들 위성에 장착된 마이크로파 센서들의 검보정법을 설명하면서, 센서들의 중요한 특징들과 주요 임무에 대해서 요약 정리하였다.

  • PDF