• 제목/요약/키워드: Calibration Correction

검색결과 369건 처리시간 0.03초

표준저항기를 이용한 전압변성기 비교기의 비오차 평가 (Evaluation for Ratio Error of Voltage Transformer Comparator using Standard Resistors)

  • 한상길;김윤형;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.412-416
    • /
    • 2008
  • We have developed the calibration technique of the VT comparator using nonreactive standard resistors, which evaluates both accuracy and linearity of the VT comparator by comparing experimental values with theoretical values. The correction values of VT comparator obtained by using both our method and wide ratio error VT are consistent within the expanded uncertainty. Furthermore the specification for ratio error of VT comparator have been revaluated.

COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증 (Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite)

  • 문윤섭;이강열
    • 한국지구과학회지
    • /
    • 제37권7호
    • /
    • pp.420-433
    • /
    • 2016
  • 본 연구의 목적은 2011년 4월 22일부터 10월 22일까지 우리나라에서 강수가 있는 총 75일 동안 COMS 위성의 적외 채널 $10.8{\mu}m$ 휘도 온도(IR), 적외 채널 $10.8{\mu}m$와 수증기 채널 $6.7{\mu}m$의 휘도 온도차(IR-WV), 정규화 된 가시반사도(VIS)와 기상 레이더의 강우강도를 이용하여 2-D와 3-D 대류운의 강우강도 (CRR) 조견표를 향상시키는 것이다. 특별히 한국형 2-D와 3-D CRR 조견표를 검증하기 위해 2011년 강수가 있는 24일 동안의 기상 레이더 강우강도 자료가 사용된다. 2-D와 3-D CRR 조견표는 각 채널의 등급 범주별 강우 총수와 비강우 총수의 행렬을 이용하여 구한 강우 확률에 평균 누적강우강도와 최대 강우강도를 각각 곱함으로써 2-D (IR, IR-WV)와 3-D (IR, IR-WV, VIS) 조견표의 기본과 최대 행렬을 얻을 수 있다. 최종적으로 새로운 2-D와 3-D의 CRR 조견표는 경험적으로 기본과 최대 강우강도 행렬의 회귀 분석으로 얻어진다. 그 결과 새로운 CRR 조견표는 기존보다 낮은 IR 휘도 온도, 낮은 IR-WV 휘도 온도차일 때에도 비교적 많은 강우 현상을 나타내며, $10mm\;h^{-1}$ 이상의 강우강도 영역이 확대되어 나타난다. 정확도와 범주별 통계가 주어진 기간 동안 발생했던 CRR 자료에 대해 계산된다. 새로운 2-D와 3-D CRR 조견표의 평균 오차, 평균절대 오차, 제곱근평균 오차가 기존 조견표보다 작게 나타나며, 예측 거짓경고비율은 감소하고, 탐지확률은 증가하며, 임계성공지수는 개선된다. 태풍과 뇌우와 같은 기상 이변에서의 강한 호우를 고려하기 위해서 습윤 보정 계수를 교정한다. 이 인자는 수치모델이나 COMS에서 복원한 지면에서 500 hPa까지 평균한 총가강수량과 상대습도의 곱 (PW RH)으로 정의된다. 이 연구에서는 PW RH에 근거하여 IR 운정 휘도 온도가 210 K 이하일 때, 상대습도가 40% 이상일 때 1에서 2사이를 경험적으로 정한다. 새로운 2-D와 3-D CRR 조견표를 적용한 결과 평균 오차, 평균 절대 오차, 제곱근 평균 오차가 줄어든다.

DXA를 이용한 전완부와 요추부 골밀도 검사의 보정계수 및 상관관계 연구 (The Correlation Analysis and Correction factor of BMD in Forearm and Lumbar with DXA)

  • 한만석
    • 디지털융복합연구
    • /
    • 제11권12호
    • /
    • pp.551-556
    • /
    • 2013
  • 전완부와 요추부의 골밀도 검사를 통해 얻은 골밀도 값, T-score 와 Z-score 수치간의 상관관계 및 보정함수를 구해 어느 한 부위의 결과로서 다른 부위의 결과를 유추하는데 목적이 있다. 환자 66명은 연령별로 11명씩 20대에서 70대까지 환자들로 구성하였고 측정된 전완부와 요추부의 골밀도와 T-score와 Z-score를 조사하여 세가지 사항들에 대해 각각 상관관계가 있는지 평가하고 그 상관관계를 구하여 보정계수를 찾는다. 골밀도의 상관계수는 R=0.769 이고 보정계수 식은 Y=1.541X + 0.133 이다. T-score의 상관계수는 R=0.768 이고 보정계수식은 Y=0.715X - 0.4 이다. Z-score의 상관계수는 R=0.635 보정계수식은 Y=0.751X - 0.162 이다. 상관관계와 보정계수식를 통해 어느 한 부위의 결과로서 다른 부위의 결과를 유추할 수 있는 임상적 유용성이 있을 것으로 사료된다.

물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화 (Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards)

  • 김성훈;허현도;최상현;김찬형;민철희;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2009
  • 본 논문은 물 흡수선량 표준에 기반하여 근접치료 선원인 $^{192}Ir$을 교정하는 것에 대한 예비적 연구를 위한 것이다. 이온함을 사용하여 물흡수선량 표준에 기반하여 근접치료 선원을 교정하기 위해선, 빔 선질 교정인자인 $k_{Q,Q_0}$가 필요하다. 본 연구에선 일차 표준을 사용하여 지정된 거리에서의 흡수선량를 측정하는 데 있어서의 현실적인 어려움 때문에 몬테칼로 전산모사와 반실험적인 방법을 통하여 $k_{Q,Q_0}$를 결정하였다. 본 연구를 위해 PTW30013 이온함 5개를 선택하였다. 포괄적 $k^{gen}_{Q,Q_0}$ 값의 경우엔 이온함간 변화가 최대 4.0%에 이른 반면, 개별적 $k^{ind}_{Q,Q_0}$ 경우엔 이온함간 변화가 최대 0.5% 이내였다. 이 결과는 물 흡수선량에 기반하여 근접치료 선원인 $^{192}Ir$을 교정시에 이온함을 왜 개별적으로 교정해야 하는지, 개별적인 교정이 얼마나 중요한 지를 보여 준다. 가까운 장래에 공기커마 세기 대신에 사용자가 근접치료 선원을 고에너지 광자빔과 전자빔의 교정에서처럼 치료에서 관심있는 물리량인 물흡수선량의 관점에서 교정할 수 있기를 희망한다.

  • PDF

오픈소스 기반 다목적실용위성 3A호 영상자료의 지표면 반사도 영상 제작 실험 (An Experiment for Surface Reflectance Image Generation of KOMPSAT 3A Image Data by Open Source Implementation)

  • 이기원;김광섭
    • 대한원격탐사학회지
    • /
    • 제35권6_4호
    • /
    • pp.1327-1339
    • /
    • 2019
  • 지구 관측 위성에 의한 광학 영상정보를 육상 분야에 활용하는 경우 지표면 반사도를 나타내는 영상은 중요한 기초 정보가 된다. 지표면 반사도는 광학 영상정보에 대하여 절대 대기 보정 처리 과정을 수행하여 얻어지는 성과물이다. Landsat이나 Sentinel-2의 경우 여러 가지 단계의 대기 보정 처리 방법이 개발되어 있고, 이미 많은 상업적 소프트웨어나 오픈소스 들이 이러한 처리 알고리즘을 지원한다. 그러나 현재 KOMPSAT 3/3A호 고해상도 분광 영상정보를 이용하여 지표면 반사도 영상 제작 기능을 제공하는 도구는 거의 없고 이러한 기능을 제공하는 오픈소스가 개발되거나 발표된 경우도 없다. 이 연구에서 우분투(Ubuntu) 운영체제에서 Orfeo ToolBox(OTB) 원격탐사 오픈소스에 포함된 광학 보정(Optical Calibration) 모듈과 알고리즘을 기반으로 하여 KOMPSAT 3A호 영상에 대한 절대 대기 보정을 처리할 수 있는 모듈을 새로 구현하였다. 이 모듈은 KOMPSAT 영상의 센서 모델 변수와 분광 자료들을 포함하기 때문에 대기 보정 작업에 필요한 입력 변수의 자동 입력과 일괄처리가 가능하다. 이 모듈을 이용하여 상층대기(Top of Atmosphere: TOA)반사도와 지표면(Top of Canopy: TOC) 반사도를 구할 수 있다. 한편 TOC 반사도 산출과정에서는 AERONET 자료와 같은 대기 에어로졸 정보가 이용될 수 있다. 또한 이 연구에서 구현된 오픈소스 성과를 이용하여 KOMPSAT 영상을 적용한 실험을 수행하였다. 앞으로 이 오픈소스 모듈의 적용성과 무결성 검사를 수행하게 되면, 그동안 축적된 KOMPSAT 영상정보를 대상으로 하는 분석 대기 자료(Analysis Ready Data) 데이터베이스 구축에 직접 적용될 수 있다.

카메라 보정을 이용한 텍스쳐 좌표 결정에 관한 연구 (Coordinate Determination for Texture Mapping using Camera Calibration Method)

  • 정관웅;이윤영;하성도;박세형;김재정
    • 한국CDE학회논문집
    • /
    • 제9권4호
    • /
    • pp.397-405
    • /
    • 2004
  • Texture mapping is the process of covering 3D models with texture images in order to increase the visual realism of the models. For proper mapping the coordinates of texture images need to coincide with those of the 3D models. When projective images from the camera are used as texture images, the texture image coordinates are defined by a camera calibration method. The texture image coordinates are determined by the relation between the coordinate systems of the camera image and the 3D object. With the projective camera images, the distortion effect caused by the camera lenses should be compensated in order to get accurate texture coordinates. The distortion effect problem has been dealt with iterative methods, where the camera calibration coefficients are computed first without considering the distortion effect and then modified properly. The methods not only cause to change the position of the camera perspective line in the image plane, but also require more control points. In this paper, a new iterative method is suggested for reducing the error by fixing the principal points in the image plane. The method considers the image distortion effect independently and fixes the values of correction coefficients, with which the distortion coefficients can be computed with fewer control points. It is shown that the camera distortion effects are compensated with fewer numbers of control points than the previous methods and the projective texture mapping results in more realistic image.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

위성 데이터에 의한 선박 탐지: RADARSAT의 대기보정과 기하보정 (Ship Detection by Satellite Data: Radiometric and Geometric Calibrations of RADARS AT Data)

  • 양찬수
    • 해양환경안전학회지
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2004
  • RADARSAT 위성은 레이더센서를 가지고 있어 전천후 및 주야불문이라는 두 가지 주요 이점을 가지고 있기 때문에, 선박탐지를 포함하는 해상감시 분야에 있어서 중요한 역할을 할 수 있다 그러나, 합성개구레이더의 이미징 시에 대기의 영향은 무시될 수 없으며, 또한 다양한 형태로 기하 변형이 발생하게 된다. 본 연구에서는, 레벨 1의 georeferenced SGX 데이터를 사용해서 RADARSAT의 합성개구레이더에 대한 대기/기하 보정을 실시하였다. 동일 이미지 내에서도, near range와 far range 세션의 비교를 위해서도 이와 같은 보정이 필요하다. 대기 보정은 후방산란에 대한 국소 조사부분과 입사각의 효과를 보정하여 수행되었으며, DN값은 beta nought와 sigma nought로 변환시켰다. 마지막으로 위성자세정보에서 추정되는 4점의 위치정보를 이용하여 자동 기하보정을 실시하였으며, 그 결과를 실제 좌표 값과 비교하였다. 오차는 위도방향으로 300m, 경도방향으로 260m범위 내에 있는 것으로 확인되었다. 이것은 추가로 지상기준점을 통해 보정될 수 있으며, 외해의 경우에는 적용 가능한 것으로 판단된다.

  • PDF

LPDDR2 메모리 컨트롤러를 위한 830-Mb/s/pin 송수신기 칩 구현 (Chip Implementation of 830-Mb/s/pin Transceiver for LPDDR2 Memory Controller)

  • 이종혁;송창민;장영찬
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.659-670
    • /
    • 2022
  • 본 논문에서는 ×32 LPDDR2 메모리를 지원하는 컨트롤러를 위한 830-Mb/s/pin 송수신기가 설계된다. 여덟 개의 단위 회로로 구성된 송신단은 34Ω ∽ 240Ω 범위의 임피던스를 가지고 임피던스 보정 회로에 의해 제어된다. 송신되는 DQS의 신호는 DQ의 신호들 대비 90° 이동된 위상을 가진다. 수신 동작시 read time 보정은 바이트 내에서 per-pin 스큐 보정과 클록-도메인 전환을 통해 수행된다. 구현된 LPDDR2 메모리 컨트롤러를 위한 송수신기는 1.2V 공급 전압을 사용하는 55-nm 공정에서 설계되었으며 830-Mb/s/pin의 신호 전송률을 가진다. 각 lane의 면적과 전력 소모는 각각 0.664 mm2과 22.3 mW이다.