• Title/Summary/Keyword: Calibration Correction

Search Result 366, Processing Time 0.031 seconds

Development of a Residual Gas Analyzer Calibration System (잔류기체 분석기 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Kim, J.T.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 2007
  • The Korea Research Institute of Standards and Science (KRISS) has developed a residual gas analyzer (RGA) calibration system and measured gas sensitivities for two different types QMSs using nitrogen, argon, and helium. Different gas sensitivities were identified according to mass and pressure, so it was revealed that the gas sensitivity correction is necessary for proper use of mass spectrometers.

Radiometric Calibration Method of the GOCI (Geostationary Ocean Color Imager)

  • Kang, Gumsil;Myung, Hwan-Chun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.60-63
    • /
    • 2006
  • Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of oceancolor around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. In this paper radiometric calibration concept of the GOCI is introduced. The GOCI radiometric response is modeled as a nonlinear system in order to reflect a nonlinear characteristic of detector. In this paper estimation approaches for radiometric parameters of GOCI model are discussed. For the GOCI, the offset signal depends on each spectral channel because dark current offset signal is a function of integration time which is different from channel to channel. The offset parameter can be estimated by using offset signal measurements for two integration time setting is described.

  • PDF

Analyzing effects of correction of image distortion according to the number of patterns, size of image files and the number of image files (패턴 개수, 이미지 파일 크기, 이미지 파일 개수가 영상왜곡보정에 미치는 영향 분석)

  • Cheon, Sang-kyu;Jang, Si-woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.311-314
    • /
    • 2013
  • 방사왜곡, 접선왜곡으로 인해 영상의 왜곡이 발생한다. 왜곡 영상은 시각적인 문제 외에도 영상분석을 통해 정확한 수치 계산을 통해 영상을 처리할 때, 문제가 되기 때문에 영상을 보정해 주어야한다. 감시 시스템, 로봇의 시각 역할 등 다양한 비전 시스템에서 카메라가 장착되어 왜곡보정에 대한 사용도가 증가 하고 있다. 그리고 한 광각 카메라에서 획득한 영상은 비선형적인 방사 왜곡을 가지고 있기 때문에 정확한 영상을 획득하기 위해서는 왜곡 보정 작업을 수행하여야 한다. 왜곡된 영상을 올바르게 보정 해줄 캘리브레이션(Calibration)은 영상 좌표계의 한 점이 실세계 좌표계의 어느 위치에 대응하는지를 결정하기 위해 보정 변수들을 결정하는 과정이다. 본 논문에서는 캘리브레이션(Calibration)을 수행할 때 패턴 개수, 이미지 파일 크기, 이미지 파일 개수가 영상 왜곡 보정에 어떤 영향을 미치는지 분석해 보았을 때 다른 어떤 경우보다 패턴 개수를 비교적 작게 했을 때의 경우가 뚜렷한 차이를 보여주었다.

  • PDF

Hardware Implementation of Time Skew Calibration Block for Time Interleaved ADC (TI ADC를 위한 시간 왜곡 교정 블록의 하드웨어 구현)

  • Khan, Sadeque Reza;Choi, Goangseog
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.3
    • /
    • pp.35-42
    • /
    • 2017
  • This paper presents hardware implementation of background timing-skew calibration technique for time-interleaved analog-to-digital converters (TI ADCs). The timing skew between any two adjacent analog-digital (A/D) channels is detected by using pure digital Finite Impulse Response (FIR) delay filter. This paper includes hardware architecture of the system, main units and small sub-blocks along with control logic circuits. Moreover, timing diagrams of logic simulations using ModelSim are provided and discussed for further understanding about simulations. Simulation process in MATLAB and Verilog is also included and provided with basic settings need to be done. For hardware implementation it not practical to work with all samples. Hence, the simulation is conducted on 512 TI ADC output samples which are stored in the buffer simultaneously and the correction arithmetic is done on those samples according to the time skew algorithm. Through the simulated results, we verified the implemented hardware is working well.

Validation of Calibrated Wind Data Sector including Shadow Effects of a Meteorological Mast Using WindSim (WindSim을 이용한 풍황탑 차폐오차 구간의 보정치 검증)

  • Park, Kun-Sung;Ryu, Ki-Whan;Kim, Hyun-Goo
    • Journal of Wind Energy
    • /
    • v.4 no.2
    • /
    • pp.34-39
    • /
    • 2013
  • The wind resource assessment for measured wind data over 1 year by using the meteorological mast should be a prerequisite for business feasibility of the wind farm development. Even though the direction of boom mounting the wind vane and anemometer is carefully engineered to escape the interference of wakes generated from the met-mast structures, the shadow effect is not completely avoided due to seasonal winds in the Korean Peninsula. The shadow effect should be properly calibrated because it is able to distort the wind resources. In this study a calibration method is introduced for the measured wind data at Julpo in Jeonbuk Province. Each sectoral terrain conditions along the selected wind direction nearby the met-mast is investigated, and the distorted wind data due to shadow effects can be calibrated effectively. The correction factor is adopted for quantitative calibration by carrying out the WindSim analysis.

Comparison of Correction Coefficients for the Non-uniformity of Pixel Response in Satellite Camera Electronics (위성카메라 전자부의 화소간 응답불균일성 보정계수의 비교검토)

  • Kong, Jong-Pil;Lee, Song-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Four kinds of gain and offset correction coefficients that are used to correct the nonuniformity between pixels are discussed. And their correction performance has been compared by performing image correction. using the correction coefficients calculated, on the real image data obtained from a newly fabricated camera electronics system. The performance of the correction coefficients depends in general on the number of the light input levels used to obtain the reference image. The result shows that, as expected obviously, when only two light input levles are used to obtain the reference image, even though its correction coefficients are relatively easily calculated, the correction performance is relatively poor. And with the number of light inputs increased to a value of larger than two, the correction performance is improved. It is noted, however, no Significant performance difference is found between the different correction coefficients employed.

Correction Factor for the Eenergy Dependence of a Optically Stimulated Luminescent Dosimeter in Diagnostic Radiography (진단방사선촬영에서 광자극형광선량계의 에너지의존성에 대한 보정인자)

  • Kim, Jong-Eon;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.261-265
    • /
    • 2011
  • The purpose of this study is to calculate correction factors for energy dependence of a nanoDotdosimeter to measure patient's skin dose in diagnostic radiography. The correction factors were calculated by using the values of mean energy for the RQR standard radiation qualities of IEC publicated by Rosado et al. and the energy response graph of dosimeter relative X-ray on phantom calibration provided by landaur corporation. Results showed the correction factors of 1-1.33 over the tube voltage range of 40-50 kVp. Acquired correction factors are considered to be useful in the clinics for the measurement of accurate skin dose at each tube voltage.

Amplitude Correction Factors of KVN Observations Correlated by DiFX and Daejeon Correlators

  • Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2015
  • We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22 GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institue (KASI) with Very Long Baseline Array (VLBA) observations at 22 GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3 and NRAO 512 which are almost unresolved for baselines in a range of 350-477 km. VLBA visibility data of the sources observed with similar baselines as KVN are selected, fringe-fitted, calibrated, and compared in their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.14 and 1.40 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.

  • PDF

KOMPSAT-2 NON-UNIFORMITY CORRECTION ALGORITHM (다목적 실용위성2호의 NON-UNIFORMITY CORRECTION 알고리즘)

  • Park, Su-Young;Song, Jeong-Heon;Lee, Dong-Han;Seo, Doo-Chun;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.305-307
    • /
    • 2007
  • KOMPSAT-2(K-2) 의 MSC 는 CCD pixel 별 band 별 특성, 감도 및 시간에 따른 변화, CCD Geometry 등에 의해 왜곡 현상이 일어나며 위성 발사 전에 실험실에서의 충분한 실험과 Calibration 작업 을 통해 얻어진 값들을 사용하여 Image Restoration, 상대 복사 보정, 절대 복사 보정 등의 작업들을 거쳐서 왜곡 현상을 보정하게 된다. 그 중 복사 보정에 해당하는 NUC(NonUniformity Correction)은 MSC 각각의 픽셀들이 상이한 특성을 나타내는 것을 균일한 이미지로 보정하는 작업으로 무엇보다 우선시 되는 검보정 작업이다. K-2 NUC table 생성에는 시스템 특성상 몇 가지 사항을 고려 하여 위성에 upload 하는 high frequency NUC(HF NUC)과 지상국에서 처리할 수 있는 low frequency NUC(LF NUC)으로 구분하여 알고리즘을 생성하였다.

  • PDF