• Title/Summary/Keyword: Calibration & Validation

Search Result 661, Processing Time 0.033 seconds

Estimation of the Hapcheon Dam Inflow Using HSPF Model (HSPF 모형을 이용한 합천댐 유입량 추정)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.69-77
    • /
    • 2019
  • The objective of this study was to calibrate and validate the HSPF (Hydrological Simulation Program-Fortran) model for estimating the runoff of the Hapcheon dam watershed. Spatial data, such as watershed, stream, land use, and a digital elevation map, were used as input data for the HSPF model. Observed runoff data from 2000 to 2016 in study watershed were used for calibration and validation. Hydrologic parameters for runoff calibration were selected based on the user's manual and references, and trial and error method was used for parameter calibration. The $R^2$, RMSE (root-mean-square error), RMAE (relative mean absolute error), and NSE (Nash-Sutcliffe efficiency coefficient) were used to evaluate the model's performance. Calibration and validation results showed that annual mean runoff was within ${\pm}4%$ error. The model performance criteria for calibration and validation showed that $R^2$ was in the rang of 0.78 to 0.83, RMSE was 2.55 to 2.76 mm/day, RMAE was 0.46 to 0.48 mm/day, and NSE was 0.81 to 0.82 for daily runoff. The amount of inflow to Hapcheon Dam was calculated from the calibrated HSPF model and the result was compared with observed inflow, which was -0.9% error. As a result of analyzing the relation between inflow and storage capacity, it was found that as the inflow increases, the storage increases, and when the inflow decreases, the storage also decreases. As a result of correlation between inflow and storage, $R^2$ of the measured inflow and storage was 0.67, and the simulated inflow and storage was 0.61.

Automatic Calibration for Noncontinuous Observed Data using HSPF-PEST (HSPF-PEST를 이용한 불연속 실측치 자동보정)

  • Jeon, Ji-Hong;Lee, Sae-Bom
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.111-119
    • /
    • 2012
  • Applicability of 8 day interval flow data for the calibration of hydrologic model was evaluated using Hydrological Simulation Program-Fortran (HSPF) at Kyungan watershed. The 8 day interval flow monitored by Ministry of Environment located at upstream was calibrated and periodically validated during 2004-2008. And continuous daily flow monitored by Ministry of Construction & Transportation (MOCT) and located at the mouth was compared with daily simulated data during 2004-2007 as spatial validation. Automatic calibration tool which is Model-Independent Parameter Estimation & Uncertainty Analysis (PEST) was applied for HSPF calibration procedure. The model efficiencies for calibration and periodic validation were 0.63 and 0.88, and model performances were fair and very good, respectively, based on criteria of calibration tolerances. Continuous daily stream flow at the mouth of Kyungan watershed were good agreement with observed continuous daily stream flow with showing 0.63 NS value. The PEST program is very useful tool for HSPF hydrologic calibration using non-continuous daily stream flow as well as continuous daily stream flow. The 8 day interval flow data monitored by MOE could be used to calibrate hydrologic model if the continuous daily stream flow is unavailable.

Evaluation of Applicability and Hydrologic Parameter Calibration for HSPF Model using Expert System for HSPF (매개변수 보정 전문가시스템을 이용한 HSPF 모형의 수문 매개변수 보정 및 적용성 평가)

  • Kim, Sung Min;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • The purpose of this study was to evaluate the applicability of the HSPEXP expert system for the calibration of the Hydrological Simulation Program - Fortran (HSPF) for the study watershed. HSPEXP offers advice to the modeler, suggesting parameter changes that might result in better representation of a river basin and provides explanations supporting the recommended parameter changes. The study watershed, Sancheong, is located within the Nakdong River Basin and having the size of $1,072.4km^2$. Input data for the HSPF model were obtained from the landuse map, digital elevation map, meteorological data and others. Water flow data from 2006 to 2008 were used for calibration and from 2009 to 2010 were for validation. Using the HSPEXP expert system, hydrological parameters were adjusted based on total volume, then low flows, storm flows, and finally seasonal flows. For the calibration and validation period, all the HSPEXP model performance criteria were satisfied.

REQUIREMENT AND INITIALIZATION OF KOMPSAT-5 CALIBRATION AND VALIDATION

  • Lee, Dong-Han;Seo, Doo-Chun;Song, Jeong-Heon;Park, Soo-Young;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.776-779
    • /
    • 2006
  • KOMPSAT-5 that will be launched at the end of 2008 has a SAR (Synthetic Aperture Radar) payload. Since the Calibration and Validation of a satellite SAR is different from a passive optical camera as KOMPSAT-2 MSC and KOMPSAT-3 payload, we have started from the basis of SAR system. Firstly, the general SAR Cal/Val parameters have been gathered and defined. Secondly, we have been choosing the Cal/Val parameters suitable to KOMPSAT-5. Thirdly, the methods of SAR Cal/Val with the parameters have been studied. Fourthly, the requirement of Cal/Val devices and Cal/Val site has been studied.

  • PDF

SPACE-BORNE MICROWAVE RADIOMETER CALIBRATION/VALIDATION IN CHINA

  • Zhenzhan, Wang;Yun, Li;Shixiang, Tan
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.598-603
    • /
    • 2002
  • We summarize the activities concerning to the space-borne microwave radiometer (RAD) calibration and validation (Cal/Val) in China. It is important to know in advance the brightness temperature of a given sea surface before external calibrating RAD due to its special characteristic of system. In the paper, we analyse some modeling results on sea surface emissivity and atmospheric transmissivity at different frequencies, and compare the calculated brightness temperatures with those measurements from some air-borne microwave radiometers. We also introduced the whole contents on RAD Val and developed two methods of retrieving sea surface winds. We compared the retrievals of wind speeds to those from NDBC buoys. At last, we introduce some plans of Cal/Val for testing our RAD.

  • PDF

Hydrologic Calibration of HSPF Model using Parameter Estimation (PEST) Program at Imha Watershed (PEST를 이용한 임하호유역 HSPF 수문 보정)

  • Jeon, Ji-Hong;Kim, Tae-Il;Choi, Donghyuk;Lim, Kyung-Jae;Kim, Tae-Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.802-809
    • /
    • 2010
  • An automatic calibration tool of Hydrological Simulation Program-Fortran (HSPF), Parameter Estimation (PEST) program, was applied at the Imha lake watershed to get optimal hydrological parameters of HSPF. Calibration of HSPF parameters was performed during 2004 ~ 2008 by PEST and validation was carried out to examine the model's ability by using another data set of 1999 ~ 2003. The calibrated HSPF parameters had tendencies to minimize water loss to soil layer by infiltration and deep percolation and to atmosphere by evapotranspiration and maximize runoff rate. The results of calibration indicated that the PEST program could calibrate the hydrological parameters of HSPF with showing 0.83 and 0.97 Nash-Sutcliffe coefficient (NS) for daily and monthly stream flow and -3% of relative error for yearly stream flow. The validation results also represented high model efficiency with showing 0.88 and 0.95, -10% relative error for daily, monthly, and yearly stream flow. These statistical values of daily, monthly, and yearly stream flow for calibration and validation show a 'very good' agreement between observed and simulated values. Overall, the PEST program was useful for automatic calibration of HSPF, and reduced numerous time and effort for model calibration, and improved model setup.

Basic Principles of the Validation for Good Laboratory Practice Institutes

  • Cho, Kyu-Hyuk;Kim, Jin-Sung;Jeon, Man-Soo;Lee, Kyu-Hong;Chung, Moon-Koo;Song, Chang-Woo
    • Toxicological Research
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Validation specifies and coordinates all relevant activities to ensure compliance with good laboratory practices (GLP) according to suitable international standards. This includes validation activities of past, present and future for the best possible actions to ensure the integrity of non-clinical laboratory data. Recently, validation has become increasingly important, not only in good manufacturing practice (GMP) institutions but also in GLP facilities. In accordance with the guideline for GLP regulations, all equipments used to generate, measure, or assess data should undergo validation to ensure that this equipment is of appropriate design and capacity and that it will consistently function as intended. Therefore, the implantation of validation processes is considered to be an essential step in a global institution. This review describes the procedures and documentations required for validation of GLP. It introduces basic elements such as the validation master plan, risk assessment, gap analysis, design qualification, installation qualification, operational qualification, performance qualification, calibration, traceability, and revalidation.

Quantification of Icariin Contents in Epimedium koreanum N. by Using a Near Infrared Reflectance Spectroscopy (NIRS를 이용한 삼지구엽초의 이카린 함량 분석)

  • Kim, Yong-Ho;Choi, Byoung-Ryourl;Baek, Hum-Young;Lee, Young-Sang
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.5
    • /
    • pp.340-343
    • /
    • 2002
  • Near infrared reflectance spectroscopy (NIRS) has become widely accepted for rapid quantitative analysis of components in some crops. Our object was to determine icariin contents in whole plant of Epimedium koreanum by using an NIRS system. Total 150 plant samples previously analyzed by HPLC were scanned by NIRS and 68 samples were selected for calibration and validation equation. A calibration equation calculated by MPLS(modified partial least squares) regression technique was developed and a coefficient of determination in calibration and validation sets were 0.95 and 0.82, respectively. A comparison between NIRS estimation and HPLC value was performed with the remaining samples not included in the calibration and validation sets. Most of samples also showed a positive correlation like a validation set. Our results demonstrate that this developed NIRS equation can be practically used as a mass screening method for rapid quantification of icarin contents in Epimedium koreanum N.

CALIBRATION AND VALIDATION OF THE HSPF MODEL ON AN URBANIZING WATERSHED IN VIRGINIA, USA

  • Im, Sang-Jun;Brannan, Kevin-M.;Mostaghimi, Saied
    • Water Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.141-154
    • /
    • 2003
  • Nonpoint source pollutants from agriculture are identified as one of the main causes of water quality degradation in the United States. The Hydrological Simulation Program-Fortran (HSPF) was used to simulate runoff, nitrogen, and sediment loads from an urbanizing watershed; the Polecat Creek watershed located in Virginia. Model parameters related to hydrology and water quality were calibrated and validated using observed hydrologic and water quality data collected at the watershed outlet and at several sub-watershed outlets. A comparison of measured and simulated monthly runoff at the outlet of the watershed resulted in a correlation coefficient of 0.94 for the calibration period and 0.74 for the validation period. The annual observed and simulated sediment loads for the calibration period were 220.9 kg/ha and 201.5 kg/ha, respectively. The differences for annual nitrate nitrogen ($NO_3$) loads between the observed and simulated values at the outlet of the watershed were 5.1% and 42.1% for the calibration and validation periods, respectively. The corresponding values for total Kjeldahl nitrogen (TKN) were 60.9% and 40.7%, respectively. Based on the simulation results, the calibrated HSPF input parameters were considered to adequately represent the Polecat Creek watershed.

  • PDF

Estimation of Chlorophyll Contents in Pear Tree Using Unmanned AerialVehicle-Based-Hyperspectral Imagery (무인기 기반 초분광영상을 이용한 배나무 엽록소 함량 추정)

  • Ye Seong Kang;Ki Su Park;Eun Li Kim;Jong Chan Jeong;Chan Seok Ryu;Jung Gun Cho
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.669-681
    • /
    • 2023
  • Studies have tried to apply remote sensing technology, a non-destructive survey method, instead of the existing destructive survey, which requires relatively large labor input and a long time to estimate chlorophyll content, which is an important indicator for evaluating the growth of fruit trees. This study was conducted to non-destructively evaluate the chlorophyll content of pear tree leaves using unmanned aerial vehicle-based hyperspectral imagery for two years(2021, 2022). The reflectance of the single bands of the pear tree canopy extracted through image processing was band rationed to minimize unstable radiation effects depending on time changes. The estimation (calibration and validation) models were developed using machine learning algorithms of elastic-net, k-nearest neighbors(KNN), and support vector machine with band ratios as input variables. By comparing the performance of estimation models based on full band ratios, key band ratios that are advantageous for reducing computational costs and improving reproducibility were selected. As a result, for all machine learning models, when calibration of coefficient of determination (R2)≥0.67, root mean squared error (RMSE)≤1.22 ㎍/cm2, relative error (RE)≤17.9% and validation of R2≥0.56, RMSE≤1.41 ㎍/cm2, RE≤20.7% using full band ratios were compared, four key band ratios were selected. There was relatively no significant difference in validation performance between machine learning models. Therefore, the KNN model with the highest calibration performance was used as the standard, and its key band ratios were 710/714, 718/722, 754/758, and 758/762 nm. The performance of calibration showed R2=0.80, RMSE=0.94 ㎍/cm2, RE=13.9%, and validation showed R2=0.57, RMSE=1.40 ㎍/cm2, RE=20.5%. Although the performance results based on validation were not sufficient to estimate the chlorophyll content of pear tree leaves, it is meaningful that key band ratios were selected as a standard for future research. To improve estimation performance, it is necessary to continuously secure additional datasets and improve the estimation model by reproducing it in actual orchards. In future research, it is necessary to continuously secure additional datasets to improve estimation performance, verify the reliability of the selected key band ratios, and upgrade the estimation model to be reproducible in actual orchards.