• Title/Summary/Keyword: Calculated AC/A

Search Result 267, Processing Time 0.034 seconds

Study on Proximal Convergence/Accommodation(PC/A) Ratio by Comparison of Gradient AC/A Ratio and Calculated AC/A Ratio (Gradient AC/A비와 Calculated AC/A비의 비교에 의한 근접성 폭주비(PC/A)에 관한 연구)

  • Han, Gyeong-Ae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.223-231
    • /
    • 2004
  • In most previous studies, the assessment of accommodative convergence to accommodative stimulus (AC/A) ratio was commonly made by measuring gradient AC/A ratio. This study deals with the proximal convergence/accommodation(PC/A)ratio measured by comparing values of the gradient AC/A ratio and the calculated AC/A ratio to prevail the clinical use of the AC/A ratio. Visual acuities of All 124 subjects had been corrected to at least 1.0 with either eye through their habitual refractive correction and the MEM dynamic retinoscopy was performed to estimate their accommodative response. And then the PC/A ratio was calculated by making use of the calculated AC/A ratio and the gradient AC/A ratio. This study showed that the difference between the mean calculated AC/A ratio and the mean gradient AC/A ratio in subgroups may be attributable to proximal convergence. Consequently, further studies on proximity cues including the PC/A ratio could be helpful to prevail the clinical use of the AC/A ratio.

  • PDF

Study on the Influence of LASIK on Binocular Change (양안시 변화에 대한 라식수술의 영향에 관한 연구)

  • Lee, Ki-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.267-273
    • /
    • 2006
  • For this study, we measured heterophoria, Calculated AC/A, Gradient AC/A of pre & post LASIK operation. In case of heterophoria, the results showed that orthophoria 2.78% decreased, exophoria 2.78% increased on pre & post op distance phoria and exophoria 5.55% increased, esophoria 5.55% decreased on pre & post op near phoria. In case of AC/A, Calculated AC/A significantly decreased as 0.36 at AC/A and accommodation decreased as 1.25D (p<0.05). It showed that Gradient AC/A decreased 0.34 and PC/A increased 0.09 but they didn't show significant difference.

  • PDF

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Comparison of Magnetic Field and AC Losses in Solenoid Coil and Pancake Coil with HTS tape

  • Park, Myungjin;Lee, Kwangyoun;Jungwook Sim;Gueesoo Cha;Lee, Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.97-101
    • /
    • 2003
  • When HTS tapes are used in power application, they are used by winding form, such as, a pancake and a solenoid. When AC current is applied to the coil, Ac magnetic field is generated in winding. This AC magnetic field acts as an external magnetic field and makes loss. In this paper the radial magnetic field component ($B_r$) and the axial magnetic field component ($B_z$) in a pancake and a solenoid were calculated by numerical analysis method and compare with measured value. AC losses of a short sample were calculated by Norris equation and n numerical analysis based on Brandt equation. AC losses of the pancake coil and the solenoid coil were also calculated.

Numerical Study on Thermal Deformation of AC4C and AC7A Casting Material (AC4C와 AC7A 주조재의 열변형 수치해석적 연구)

  • Yoon, Hee-Sung;Oh, Yool-Kwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.541-546
    • /
    • 2011
  • This study was numerically investigated on thermal deformation of AC4C and AC7A aluminum alloy casting material for manufacturing the automobile tire mold. The metal casting device was used in order to manufacture the mold product of automobile tire at the actual industrial field. The temperature distribution and the cooling time of these materials were numerically calculated by finite element analysis. Thermal deformation with stress distribution was also calculated form the temperature distribution results. The thermal deformation was closely related to the temperature difference between the surface and inside of the casting. As shown by numerical analysis result, the thermal deformation of AC7A casting material became higher than AC4C casting material. In addition, the results of displacement and stress distributions appeared to be larger at the center parts of casting than on its sides because of the shrinkage caused by the cooling speed difference.

Characteristics of the HTS Stacked Tapes and AC Losses of the Multi-Stacked Pancake Coil (고온초전도 적층선재의 특성과 적층선재로 제작한 팬케이크 권선 손실)

  • Lee Seungwook;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.658-663
    • /
    • 2004
  • According to the improvement of the HTS wires performance, several tapes of HTS superconducting machines are being developed. Stacked HTS tapes are used as conductor that can flow high current for the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external filed and AC losses should be examined. In this paper, we present characteristic of the stacked HTS tapes and AC losses of HTS pancake windings with stacked tapes. AC loss of the pancake winding were measured and compared with the calculated loss by using AC loss data of the stacked samples and the magnetic flux density in the HTS winding under operating conditions. We can see that measured results generally agree well with the calculated results by using AC loss data of 4-stacked sample.

Output AC Voltage Control of a Three-Phase Z-Source Inverter by the Voltage Gain and Modulation Index Control (전압 이득과 변조지수 제어에 의한 3상 Z-소스 인버터의 출력 교류 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Yang, Seung-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1996-2005
    • /
    • 2010
  • This paper proposes a new method for constant control of the output AC voltage of a voltage-fed three phase Z-source inverter (ZSI), in case of Z-network DC voltage variation or heavy change of load. The modulation index for the reference output AC voltage of ZSI can be calculated by the basic definition of ZSI, the input DC voltage and capacitor voltage of Z-network. And, the output AC voltage of ZSI is controlled by the modified space vector modulation (SVM) with the calculated modulation index. By the proposed method, the modulation index of output AC voltage is closely following in the reference modulation index. The validity of the proposed method is verified using PSIM simulation. In case which the input DC voltage of ZSI is heavily changed from 100[V] to 70[V] (or to 150[V]) and in case which load is changed from $30[\Omega]$ to $10[\Omega]$, we confirmed that the output AC voltage of ZSI is constantly controlled by the proposed method because the modulation index of ZSI is also simultaneously changed. Finally, FFT and %THD of the output voltage and current of ZSI by the proposed method are analyzed.

Control of Linear Compressor System Using Virtual AC Capacitor

  • Park, Shin-Hyun;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2317-2323
    • /
    • 2017
  • Recently, linear compressors of cooling systems such as refrigerators, which have a free piston driven by a linear motor, have attracted much attention because of their high efficiency. For structural reasons, linear compressors applied in refrigerators should use an AC capacitor to ensure stable control. However, AC capacitors are expensive and bulky. In this paper, we propose a new method to realize stable control without a real AC capacitor by implementing a virtual AC capacitor with software. To realize a virtual AC capacitor, a pure integral is calculated. Nonetheless, if an offset current exists, the calculation may diverge to infinity. To solve this problem, a high-pass filter is applied and the compensation for the phase angle and magnitude are realized with a new method. Finally, a virtual AC capacitor enables variable frequency operations. Hence, in case of a lack of voltage, we can compensate by running the linear compressor in high-frequency operations. To improve efficiency, we may optimize the operation frequency. The validity of a virtual AC capacitor has been verified through simulations and experimental results.

DC-Link Capacitance Estimation using Support Vector Regression in AC/DC/AC PWM Converters (SVR을 이용한 AC/DC/AC PWM 컨버터의 직류링크 커패시턴스 추정)

  • Ahmed G. Abo-Khalil;Jang, Jeong-Ik;Lee, Dong-Choon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.81-87
    • /
    • 2007
  • This paper proposes a new capacitance estimation scheme for a DC-link capacitor in a three-phase AC/DC/AC PWM converter. A controlled AC voltage with a lower frequency than the line frequency is injected into the DC-link voltage, which then causes AC power ripples at the DC side. By extracting the AC voltage and power components on the DC output side using digital filters, the capacitance can then be calculated using the Support Vector Regression (SVR). By training of SVR, a function which relates a given input (capacitor's power) and its corresponding output (capacitance value) can be derived. This function is used to predict outputs for given inputs that are not included in the training set. The proposed method does not require the information of DC-link current and can be simply implemented with only software and no additional hardware. Experimental results confirm that the estimation error is less than 0.16%.