Pedicle Screw Placement in the Thoracolumbar Spine Using a Novel, Simple, Safe, and Effective Guide-Pin : A Computerized Tomography Analysis

  • Hyun, Seung-Jae;Kim, Yongjung J.;Rhim, Seung-Chul;Cheh, Gene;Cho, Samuel K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • Objective : To improve pedicle screw placement accuracy with minimal radiation and low cost, we developed specially designed K-wire with a marker. To evaluate the accuracy of thoracolumbar pedicle screws placed using the novel guide-pin and portable X-rays. Methods : Observational cohort study with computerized tomography (CT) analysis of in vivo and in vitro pedicle screw placement. Postoperative CT scans of 183 titanium pedicle screws (85 lumbar and 98 thoracic from T1 to L5) placed into 2 cadavers and 18 patients were assessed. A specially designed guide-pin with a marker was inserted into the pedicle to identify the correct starting point (2 mm lateral to the center of the pedicle) and aiming point (center of the pedicle isthmus) in posteroanterior and lateral X-rays. After radiographically confirming the exact starting and aiming points desired, a gearshift was inserted into the pedicle from the starting point into the vertebral body through the center of pedicle isthmus. Results : Ninety-nine percent (181/183) of screws were contained within the pedicle (total 183 pedicle screws : 98 thoracic pedicle screws and 85 lumbar screws). Only two of 183 (1.0%) thoracic pedicle screws demonstrated breach (1 lateral in a patient and 1 medial in a cadaver specimen). None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusion : A simple, specially designed guide-pin with portable X-rays can provide correct starting and aiming points and allows for accurate pedicle screw placement without preoperative CT scan and intraoperative fluoroscopic assistance.

Meningeal Layers Around Anterior Clinoid Process as a Delicate Area in Extradural Anterior Clinoidectomy : Anatomical and Clinical Study

  • Yoon, Byul Hee;Kim, Han Kyu;Park, Mun Sun;Kim, Seong Min;Chung, Seung Young;Lanzino, Giuseppe
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.391-395
    • /
    • 2012
  • Objective : Removal of the anterior clinoid process (ACP) is an essential process in the surgery of giant or complex aneurysms located near the proximal internal carotid artery or the distal basilar artery. An extradural clinoidectomy must be performed within the limits of the meningeal layers surrounding the ACP to prevent morbid complications. To identify the safest method of extradural exposure of the ACP, anatomical studies were done on cadaver heads. Methods : Anatomical dissections for extradural exposure of the ACP were performed on both sides of seven cadavers. Before dividing the frontotemporal dural fold (FTDF), we measured its length from the superomedial apex attached to the periorbita to the posterolateral apex which connects to the anterosuperior end of the cavernous sinus. Results : The average length of the FTDF on cadaver dissections was 7 mm on the right side and 7.14 mm on the left side. Cranial nerves were usually exposed when cutting FTDF more than 7 mm of the FTDF. Conclusion : The most delicate area in an extradural anterior clinoidectomy is the junction of the FTDF and the anterior triangular apex of the cavernous sinus. The FTDF must be cut from the anterior side of the triangle at the periorbital side rather than from the dural side. The length of the FTDF incision must not exceed 7 mm to avoid cranial nerve injury.

Morphometric Relationship between the Cervicothoracic Cord Segments and Vertebral Bodies

  • Kim, Ji Hoon;Lee, Chul Woo;Chun, Kwon Soo;Shin, Won Han;Bae, Hack-Gun;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.384-390
    • /
    • 2012
  • Objective : The objective of this study was to investigate the morphologic characteristics between the vertebral body and the regions of the cervical and thoracic spinal cords where each rootlets branch out. Methods : Sixteen adult cadavers (12 males and 4 females) with a mean age of 57.9 (range of 33 to 70 years old) were used in this study. The anatomical relationship between the exit points of the nerve roots from the posterior root entry zone at each spinal cord segment and their corresponding relevant vertebral bodies were also analyzed. Results : Vertical span of the posterior root entry zone between the upper and lower rootlet originating from each spinal segment ranged from 10-12 mm. The lengths of the rootlets from their point of origin at the spinal cord to their entrance into the intervertebral foramen were 5.9 mm at the third cervical nerve root and increased to 14.5 mm at the eighth cervical nerve root. At the lower segments of the nerve roots (T3 to T12), the posterior root entry zone of the relevant nerve roots had a corresponding anatomical relationship with the vertebral body that is two segments above. The posterior root entry zones of the sixth (94%) and seventh (81%) cervical nerve roots were located at a vertebral body a segment above from relevant segment. Conclusion : Through these investigations, a more accurate diagnosis, the establishment of a better therapeutic plan, and a decrease in surgical complications can be expected when pathologic lesions occur in the spinal cord or vertebral body.

Anatomical Morphometric Study of the Cervical Uncinate Process and Surrounding Structures

  • Kim, Sung-Ho;Lee, Jae Hack;Kim, Ji Hoon;Chun, Kwon Soo;Doh, Jae Won;Chang, Jae Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.300-305
    • /
    • 2012
  • Objective : The purpose of this study is to elucidate the anatomic relationships between the uncinate process and surrounding neurovascular structures to prevent possible complications in anterior cervical surgery. Methods : Twenty-eight formalin-fixed cervical spines were removed from adult cadavers and were studied. The authors investigated the morphometric relationships between the uncinate process, vertebral artery and adjacent nerve roots. Results : The height of the uncinate process was 5.6-7.5 mm and the width was 5.8-8.0 mm. The angle between the posterior tip of the uncinate process and vertebral artery was $32.2-42.4^{\circ}$. The distance from the upper tip of the uncinate process to the vertebral body immediately above was 2.1-3.3 mm, and this distance was narrowest at the fifth cervical vertebrae. The distance from the posterior tip of the uncinate process to the nerve root was 1.3-2.0 mm. The distance from the uncinate process to the vertebral artery was measured at three different points of the uncinate process : upper-posterior tip, lateral wall and the most antero-medial point of the uncinate process, and the distances were 3.6-6.1 mm, 1.7-2.8 mm, and 4.2-5.7 mm, respectively. The distance from the uncinate process tip to the vertebral artery and the angle between the uncinate process tip and vertebral artery were significantly different between the right and left side. Conclusion : These data provide guidelines for anterior cervical surgery, and will aid in reducing neurovascular injury during anterior cervical surgery, especially in anterior microforaminotomy.

Morphometric Study of the Lumbar Posterior Longitudinal Ligament

  • Lee, Sang Beom;Chang, Jae Chil;Lee, Gwang Soo;Hwang, Jae Chan;Bae, Hack Gun;Doh, Jae Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.89-96
    • /
    • 2018
  • Objective : Morphometric data for the lumbar posterior longitudinal ligament (PLL) was investigated to identify whether there is a difference in the morphometry of the PLL of the lumbar spine at each level with respect to the pattern of intervertebral disc displacement. Methods : In 14 formalin-fixed adult cadavers (12 males and 2 females), from L1 to L5, the authors measured the width and height of the PLL and compared them with other landmarks such as the disc and the pedicle. Results : Horizontally, at the upper margin of the disc, the central portion of the superficial PLL covered 17.8-36.9% of the disc width and the fan-like portion of the PLL covered 63.9-76.7% of the disc width. At the level of the median portion of the disc, the PLL covered 69.1-74.5% of the disc width. Vertically, at the level of the medial margin of the pedicle, the fan-like portion of the PLL covered 23.5-29.9% of the disc height. In general, a significant difference in length was not found in the right-left and male-female comparisons. Conclusion : This study presents the morphometric data on the pattern of intervertebral disc displacement and helps to improve the knowledge of the surgical anatomy of the lumbar PLL.

Reconstruction of the Extended Region of the Upper Auricle Using the Superior Auricular Artery Island Flap (상이개동맥 도상피판을 이용한 이개상부 및 그 주변부의 재건)

  • Kyung, Hyun Woo;Oh, Sang-Ha;Seo, Young Joon;Kim, Dong-Woon
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.289-293
    • /
    • 2009
  • Purpose: The retroauricular flap has many advantages for facial reconstruction and is being performed by many surgeons. However, it is difficult for the retroauricular flap to perform reconstruction of the upper region of the auricle and its surroundings, due to limited rotation arc and length of pedicle. We successfully reconstructed the upper region of the auricle and its surroundings with retroauricular flap by using the superior auricular artery as a supplying pedicle. The purpose of this study is to present an anatomic study about the superior auricular artery and its clinical application. Methods: We investigated the relationship between the superior auricular artery and its surrounding structures through anatomic studies with 7 fresh cadavers and then applied the findings clinically. From February to December 2008, we performed 7 cases of the superior auricular artery island flap to reconstruct the defects in patients operated on skin cancer. Sizes of the defects varied form $0.8{\times}0.8cm$ to $3.5{\times}3.0cm$. Results: We found that the superior auricular artery is a reliable pedicle for the retroauricular flap, based on anatomical studies. All wounds of the patients were successfully closed. The flap donor site was primary closed except in one patient with a large defect. The aesthetic outcomes of the donor and recipient sites were satisfying. Conclusions: The superior auricular artery island flap has several advantages. Therefore, we suggest that the superior auricular artery island flap is a treatment of choice for reconstructing soft tissue defect at the upper region of the auricle and its surrounding area.

Microanatomy and Histological Features of Central Myelin in the Root Exit Zone of Facial Nerve

  • Yee, Gi-Taek;Yoo, Chan-Jong;Han, Seong-Rok;Choi, Chan-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.244-247
    • /
    • 2014
  • Objective : The aim of this study was to evaluate the microanatomy and histological features of the central myelin in the root exit zone of facial nerve. Methods : Forty facial nerves with brain stem were obtained from 20 formalin fixed cadavers. Among them 17 facial nerves were ruined during preparation and 23 root entry zone (REZ) of facial nerves could be examined. The length of medial REZ, from detach point of facial nerve at the brain stem to transitional area, and the thickness of glial membrane of central myelin was measured. We cut brain stem along the facial nerve and made a tissue block of facial nerve REZ. Each tissue block was embedded with paraffin and serially sectioned. Slices were stained with hematoxylin and eosin (H&E), periodic acid-Schiff, and glial fibrillary acid protein. Microscopy was used to measure the extent of central myelin and thickness of outer glial membrane of central myelin. Thickness of glial membrane was examined at two different points, the thickest area of proximal and distal REZ. Results : Special stain with PAS and GFAP could be differentiated the central and peripheral myelin of facial nerve. The length of medial REZ was mean 2.6 mm (1.6-3.5 mm). The glial limiting membrane of brain stem is continued to the end of central myelin. We called it glial sheath of REZ. The thickness of glial sheath was mean $66.5{\mu}m(40-110{\mu}m$) at proximal REZ and $7.4{\mu}m(5-10{\mu}m$) at distal REZ. Conclusion : Medial REZ of facial nerve is mean 2.6 mm in length and covered by glial sheath continued from glial limiting membrane of brain stem. Glial sheath of central myelin tends to become thin toward transitional zone.

Comparison of Three Different Techniques in Cervical Transpedicular Screw Insertion

  • Seo, Young-Jun;Song, Geun-Sung;Cho, Won-Ho;Choi, Byung-Kwan;Cha, Seung-Heon;Baek, Sun-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.360-365
    • /
    • 2006
  • Objective : This is a cadaver study to assess the accuracy of three cervical screw insertion techniques; the blind technique [Group I], the laminotomy technique [Group II], and the funnel technique [Group III]. Methods : Ten human cadavers embalmed with formaldehyde were prepared. After exposing the spinous processes, the laminas and the lateral masses, titanium alloy transpedicular screws were inserted from C3 to C7. A total of 100 pedicles were ramdomly assigned to one of three techniques [the blind technique : 31 screws, the laminotomy technique : 51 screws, the funnel technique: 18 screws]. Axial computed tomography with 1-mm slices, and sagittal and coronal reformation were performed to identify the accuracy of the screw insertion and the anatomic relationships. Results : In Group I, 9 screws [29%] were either contained within or penetrated less than 1mm, which were rated as successful. In Group II, 24 screws [47%] were successful. In Group III, 16 screws [89%] were successful. In the multiple comparison, there was a statistically significant difference between Groups I and III and between Groups II and III [$X^2$ test and Bonfenoni test]. Conclusion : The funnel technique can help a surgeon's understanding about the cervical pedicle more precisely than the other two techniques. The funnel technique is less dependent on lateral soft tissue retraction state.

Morphological Assessment of Cadaveric Radial, Brachial and Subclavian Arteries : A Neurointerventional Approach

  • Yilmaz, Ali;Ozkul, Ayca;Shin, Dong Seong;Im, Soo-Bin;Yoon, Seok-Mann;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • Objective : The transradial catheterization (TRC) is becoming widespread, primarily for neurointerventions. Therefore, the evaluation of radial artery puncture in clinical practice and a better understanding of the anatomy are important to improve the safety of neuroendovascular surgery. Methods : Ten formalin-fixed adult Korean cadavers were dissected to expose radial artery (RA), brachial artery (BrA) and subclvian artery (ScA), bilaterally. Vessel lengths and diameters were meaured using a caliper and distance between the specific point of vessels and the anatomical landmarks including the radial styloid process, the medial epicondyle of the humerus, the sternoclavicular joint, and the vertebral artery orifice were also measured. Results : The average length between the radial (RAPS) and the BrA puncture sites (BrAPS) and between the vertebral artery orifice (VAO) and the BrA bifurcation (BrAB) did not differ between sides (p>0.05). The average length between the radial styloid process (RSP) and the RAPS was $13.41{\pm}2.19mm$, and the RSP was $26.85{\pm}2.47mm$ from the median nerve (MN). The mean length between the medial epicondyle (ME) and the BrAPS as $44.23{\pm}5.47mm$, whereas the distance between the ME and the MN was $42.23{\pm}4.77mm$. The average VAO-ScA angle was $70.94{\pm}6.12^{\circ}$, and the length between the ScA junction (SCJ) and the VAO was $60.30{\pm}8.48mm$. Conclusion : This study provides basic anatomical information about the radial artery and the brachial route and can help improving new techniques, selection of size and shape of catheters for TRC. This can help neurointerventionists who adopt a transradial neuroendovascular approach and offers comprehensive and safe care to their patients.

A Morphometric Study of the Obturator Nerve around the Obturator Foramen

  • Jo, Se Yeong;Chang, Jae Chil;Bae, Hack Gun;Oh, Jae-Sang;Heo, Juneyoung;Hwang, Jae Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.282-286
    • /
    • 2016
  • Objective : Obturator neuropathy is a rare condition. Many neurosurgeons are unfamiliar with the obturator nerve anatomy. The purpose of this study was to define obturator nerve landmarks around the obturator foramen. Methods : Fourteen cadavers were studied bilaterally to measure the distances from the nerve root to relevant anatomical landmarks near the obturator nerve, including the anterior superior iliac spine (ASIS), the pubic tubercle, the inguinal ligament, the femoral artery, and the adductor longus. Results : The obturator nerve exits the obturator foramen and travels infero-medially between the adductors longus and brevis. The median distances from the obturator nerve exit zone (ONEZ) to the ASIS and pubic tubercle were 114 mm and 30 mm, respectively. The median horizontal and vertical distances between the pubic tubercle and the ONEZ were 17 mm and 27 mm, respectively. The shortest median distance from the ONEZ to the inguinal ligament was 19 mm. The median inguinal ligament lengths from the ASIS and the median pubic tubercle to the shortest point were 103 mm and 24 mm, respectively. The median obturator nerve lengths between the ONEZ and the adductor longus and femoral artery were 41 mm and 28 mm, respectively. Conclusion : The obturator nerve exits the foramen 17 mm and 27 mm on the horizontal and sagittal planes, respectively, from the pubic tubercle below the pectineus muscle. The shallowest area is approximately one-fifth medially from the inguinal ligament. This study will help improve the accuracy of obturator nerve surgeries to better establish therapeutic plans and decrease complications.