• 제목/요약/키워드: Cadaveric

검색결과 149건 처리시간 0.02초

Anatomical variations of the tibial nerve and their clinical correlation

  • Anita Soraya Soetoko;Dina Fatmawati
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.415-420
    • /
    • 2023
  • The tibial nerve is a branch of the sciatic nerve, which innervates the legs and feet. Anatomical variations of this nerve at the ankle are commonly found. The variation of the tibial nerve in its branching point and cross-sectional area (CSA) at the ankle is commonly related to clinical condition such as foot neuropathy. Knowledge of these variations can support the clinician in making appropriate clinical decisions. This review aims at providing knowledge on the anatomical variations of tibial nerve at ankle, as well as its clinical correlation. This review outlined the variation of the terminal branching point and CSA of the tibial nerve at the ankle in cadaveric and clinical studies.

Anatomical variation of quadratus plantae in relation with flexor digitorum brevis

  • Punnapa Raviteja;Mrudula Chandrupatla;Ramoju Harshitha;Marni Sameer Chowdary
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.562-565
    • /
    • 2023
  • The muscles of the sole have been traditionally categorized into four layers, but it is more practical to divide them into peripheral and central groups. The peripheral groups include medial and lateral groups. The central plantar muscles are more numerous and divided into superficial and deep layers. During routine dissection in the Department of Anatomy, All India Institute of Medical Sciences Bibinagar, Hyderabad, variations are been observed in the plantar intrinsic muscle in the left foot & right foot of a 53-year-old male cadaver. This is the first cadaveric report of a combination of discrepancies especially the inter-tendinous connection between quadratus plantae and flexor digitorum brevis. Similar observations in the literature were not found by us. It is important to identify and study these dissimilarities of muscles of the sole for surgeons, anatomists, radiologists and orthopaedics as these muscles and tendons are used in foot reconstructive procedures, and for the treatment of some congenital anomalies.

Uncommon configuration of intercostobrachial nerves, lateral roots, and absent medial cutaneous nerve of arm in a cadaveric study

  • Rosemol Xaviour
    • Anatomy and Cell Biology
    • /
    • 제56권4호
    • /
    • pp.570-574
    • /
    • 2023
  • The intercostobrachial nerve (ICBN) originates from the second intercostal nerve's lateral cutaneous branch, while the median nerve (MN) typically arises from the brachial plexus's lateral and medial roots. The medial cutaneous nerve of the arm, a branch of the medial cord of the brachial plexus, often connects with the ICBN. Variations were observed during the dissection of a 50-year-old male cadaver, including MN having two lateral roots (LR), LR1 and LR2, joining at different levels. Three ICBNs innervated the arm in this case, with the absence of the medial cutaneous nerve of the arm compensated by branches from the medial cutaneous nerve of the forearm. Understanding these anatomical variations is crucial for surgical procedures like brachioplasty, breast augmentation, axillary lymph node dissection, and orthopedic surgery. Surgeons and medical professionals must be aware of these variations to enhance preoperative planning, minimize complications, and improve patient outcomes in these procedures.

The first report of the buckled thyroid cartilage in a human cadaver

  • Craig Ballard;Joe Iwanaga;Eva Maranillo;Jose Sanudo;Aaron S. Dumont;R. Shane Tubbs
    • Anatomy and Cell Biology
    • /
    • 제56권2호
    • /
    • pp.268-270
    • /
    • 2023
  • We present the first case of buckled thyroid cartilage identified in a human cadaver. This rare anatomical variant, in patients, often produces dysphonia and is a potential source for diagnostic confusion. In the cadaveric case described, the laryngeal prominence is deviated to the left without deviation of the internal structures of the larynx, such as vocal folds and vocalis muscles. The medical history of the patient is not known. Finally, a review of current literature on the buckled thyroid cartilage is presented. Such a case represents a rare opportunity to visualize this deformity via anatomical dissection.

Buccal gland within the bucinator muscle

  • Emma R. Lesser;Arada Chaiyamoon;R. Shane Tubbs;Joe Iwanaga
    • Anatomy and Cell Biology
    • /
    • 제57권1호
    • /
    • pp.152-154
    • /
    • 2024
  • There are major and minor salivary glands that aid in the digestive process. Major glands are discrete and exist in predictable locations; minor salivary glands are more widespread and usually found dispersed in the mucosa of the mouth. Glands have their own contractile abilities, which allow them to secrete products without the assistance of vasculature or skeletal, or smooth muscle. This study will describe a cadaveric histological specimen in which an ectopic buccal gland was embedded within bucinator muscle fibers. Potential causes and explanations for this finding will be discussed, as well.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권1호
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구 (Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study)

  • 윤용철;오종건;김영우;김학준;문홍주;김남렬
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

돼지진피조직(Porcine Dermal Matrix, $Permacol^{(R)}$)을 이용한 보형물 유방재건술: 무세포성 사체 진피 (Acellular Cadaveric Dermis, $AlloDerm^{(R)}$)와 비교 연구 (Implant Breast Reconstruction Using Porcine Dermal Matrix ($Permacol^{(R)}$): A Comparative Study with Acellular Cadaveric Dermis ($AlloDerm^{(R)}$))

  • 정보람;노태석;김영석;홍종원;나동균
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.559-566
    • /
    • 2011
  • Purpose: The use of tissue expander/implant in breast reconstruction using tissue expander-implant is one of the most common surgical procedures. The use of AlloDerm as a sling to reestablish the lower pole of the pectoralis major muscle results a decrease in morbidity compared with more invasive procedures. However the use of AlloDerm is more expensive than other options. We decided to compare AlloDerm with Permacol, which has been safely used in human body reconstruction and is less costly than AlloDerm. Methods: After mastectomy, the inferolateral origin of the pectoralis major muscle was elevated. Either AlloDerm or Permacol was sutured to the chest wall at the level of the previously marked inframammary fold. The lower border of the pectoralis major muscle and the upper portion of the crescent-shaped piece of either AlloDerm or Permacol was sutured together using a tension free technique, and a tissue expander was subsequently inserted into the subpectoral-subAlloDerm (or Permacol) dual pocket. Results: AlloDerm was used in twenty-one patients (28 breasts) and Permacol was used in six patients (11 breasts) for tissue expander-implant breast reconstruction. During the mean follow-up period of 17 months (8~25 months). Two infections (7%) occurred in AlloDerm cases and four infections (36%) occurred in Permacol cases. Conclusion: This study is the first comparison of tissue expander/implant breast reconstruction using AlloDerm and Permacol. The use of Permacol resulted in more postoperative infection compared with the use of AlloDerm. This report is still limited with the small number of cases studied.

The Usefulness of Extradural Anterior Clinoidectomy for Low-Lying Posterior Communicating Artery Aneurysms : A Cadaveric Study

  • Hyoung Soo Byoun;Kyu-Sun Choi;Min Kyun Na;Sae Min Kwon;Yong Seok Nam
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권4호
    • /
    • pp.411-417
    • /
    • 2024
  • Objective : To confirm the usefulness of the extradural anterior clinoidectomy during the clipping of a low riding posterior communicating artery (PCoA) aneurysm through cadaver dissection. Methods : Anatomic measurements of 12 adult cadaveric heads (24 sides total) were performed to compare the microsurgical exposure of the PCoA and internal carotid artery (ICA) before and after clinoidectomy. A standard pterional craniotomy and transsylvian approach were performed in all cadavers. The distance from the ICA bifurcation to the origin of PCoA (D1), pre-anterior clinoidectomy distance from the ICA bifurcation to tentorium (D2), post-anterior clinoidectomy distance from the ICA bifurcation to tentorium (D3), pre-anterior clinoidectomy distance from the tentorium to the origin of PCoA (D4) and post-anterior clinoidectomy distance from the tentorium to the origin of PCoA (D5) and the distance of the ICA obtained after anterior clinoidectomy (D6) were measured. We measured the precise thickness of the blade for the Yasargil clip with a digital precision ruler to confirm the usefulness of the extradural anterior clinoidectomy. Results : Twenty-four sites were dissected from 12 cadavers. The age of the cadavers was 79.83±6.25 years. The number of males was the same as the females. The space from the proximal origin of the PCoA to the preclinoid-tentorium (D4) was 1.45±1.08 mm (max, 4.01; min, 0.56). After the clinoidectomy, the space from the proximal origin of the PCoA to the postclinoid-tentorium (D5) was 3.612±1.15 mm (max, 6.14; min, 1.83). The length (D6) of the exposed proximal ICA after the extradural clinoididectomy was 2.17±1.04 mm on the lateral side and 2.16±0.89 mm on the medial side. The thickness of the Yasargil clip blade used during the clipping surgery was 1.35 mm measured with a digital precision ruler. Conclusion : The proximal length obtained by performing an external anterior clinoidectomy is about 2 mm, sufficient for proximal control during PCoA aneurysm surgery, considering the thickness of the aneurysm clips. In a subarachnoid hemorrhage, performing an extradural anterior clinoidectomy could prevent a devastating situation during PCoA aneurysm clipping.

The Incidence and Clinical Implications of Congenital Defects of Atlantal Arch

  • Kwon, Jong-Kyu;Kim, Myoung-Soo;Lee, Ghi-Jai
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권6호
    • /
    • pp.522-527
    • /
    • 2009
  • Objective : Atlantal arch defects are rare. Few cadaveric and imaging studies have been reported on the variations of such anomalies. Our goal in this study was to examine the incidence and review the clinical implications of this anomaly. Methods : A retrospective review of 1,153 neck or cervical spine computed tomography (CT) scans was performed to identify patients with atlantal arch defects. Neck CT scans were performed in 650 patients and cervical spine CT scans were performed in 503 patients. Posterior arch defects of the atlas were grouped in accordance with the classification of Currarino et al. In patients exhibiting this anomaly, special attention was given to defining associated anomalies and neurological findings. Results : Atlantal arch defects were found in 11 (11/1153, 0.95%) of the 1,153 patients. The type A posterior arch defect was found in nine patients and the type B posterior arch defect was found in two patients. No type C, D, or E defects were observed. One patient with a type A posterior arch defect had an anterior atlantal-arch midline cleft (1/1153, 0.087%). Associated cervical spine anomalies observed included one $C_{6-7}$ fusion and two atlantal assimilations. None of the reviewed patients had neurological deficits because of atlantal arch anomalies. Conclusion : Most congenital anomalies of the atlantal arch are found incidentally during investigation of neck mass, neck pain, radiculopathy, and after trauma.