Factors Related to Successful Energy Transmission of Focused Ultrasound through a Skull : A Study in Human Cadavers and Its Comparison with Clinical Experiences

  • Jung, Na Young;Rachmilevitch, Itay;Sibiger, Ohad;Amar, Talia;Zadicario, Eyal;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.712-722
    • /
    • 2019
  • Objective : Although magnetic resonance guided focused ultrasound (MRgFUS) has been used as minimally invasive and effective neurosurgical treatment, it exhibits some limitations, mainly related to acoustic properties of the skull barrier. This study was undertaken to identify skull characteristics that contribute to optimal ultrasonic energy transmission for MRgFUS procedures. Methods : For ex vivo skull experiments, various acoustic fields were measured under different conditions, using five non-embalmed cadaver skulls. For clinical skull analyses, brain computed tomography data of 46 patients who underwent MRgFUS ablations (18 unilateral thalamotomy, nine unilateral pallidotomy, and 19 bilateral capsulotomy) were retrospectively reviewed. Patients' skull factors and sonication parameters were comparatively analyzed with respect to the cadaveric skulls. Results : Skull experiments identified three important factors related skull penetration of ultrasound, including skull density ratio (SDR), skull volume, and incidence angle of the acoustic rays against the skull surface. In clinical results, SDR and skull volume correlated with maximal temperature (Tmax) and energy requirement to achieve Tmax (p<0.05). In addition, considering the incidence angle determined by brain target location, less energy was required to reach Tmax in the central, rather than lateral targets particularly when compared between thalamotomy and capsulotomy (p<0.05). Conclusion : This study reconfirmed previously identified skull factors, including SDR and skull volume, for successful MRgFUS; it identified an additional factor, incidence angle of acoustic rays against the skull surface. To guarantee successful transcranial MRgFUS treatment without suffering these various skull issues, further technical improvements are required.

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Investigation of the dorsolateral branch of the posterior intercostal artery for use as the pedicle of a free flap: A cadaveric study and case series

  • Nam, Su Bong;Seo, Jung Yeol;Park, Tae Seo;Sung, Ji Yoon;Kim, Joo Hyoung;Lee, Jae Woo;Kim, Min Wook;Oh, Heung Chan
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.39-45
    • /
    • 2019
  • Background The dorsolateral branch of the posterior intercostal artery (DLBPI) can be easily found while harvesting a latissimus dorsi (LD) musculocutaneous flap for breast reconstruction. However, it remains unknown whether this branch can be used for a free flap and whether this branch alone can provide perfusion to the skin. We examined whether the DLBPI could be reliably found and whether it could provide sufficient perfusion. Methods We dissected 10 fresh cadavers and counted DLBPIs with a diameter larger than 2 mm. For each DLBPI, the following parameters were measured: distance from the lateral margin of the LD muscle, level of the intercostal space, distance from the spinal process, and distance from the inferior angle of the scapula. Results The DLBPI was easily found in all cadavers and was reliably located in the specified area. The average number of DLBPIs was 1.65. They were located between the seventh and eleventh intercostal spaces. The average length of the DLBPI between the intercostal space and the LD muscle was 4.82 cm. To assess the perfusion of the DLBPIs, a lead oxide mixture was injected through the branch and observed using X-rays, and it showed good perfusion. Conclusions The DLBPI can be used as a pedicle in free flaps for small defects. DLBPI flaps have some limitations, such as a short pedicle. However, an advantage of this branch is that it can be reliably located through simple dissection. For women, it has the advantage of concealing the donor scar underneath the bra band.

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

Anatomic Description of the Infraorbital Soft Tissues by Three-dimensional Scanning System

  • Peralta, Alonso Andres Hormazabal;Choi, You-Jin;Hu, Hyewon;Hu, Kyung-Seok;Kim, Hee-Jin
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.101-109
    • /
    • 2021
  • Purpose: For minimally invasive procedures, three-dimensional (3D) anatomical knowledge of the structures of the face is essential. This study aimed to describe the thickness of the skin and subcutaneous tissue and depths of the facial muscles located in the infraorbital region using a 3D scanner to provide critical clinical anatomical guidelines for improving minimally invasive cosmetic procedures. Materials and Methods: The 3D scanning images of 38 Korean cadavers (22 males and 16 females; age range: 51~94 years at the time of death) were analyzed. Eight facial landmarks (P1~P8) were marked on the cadaveric faces. The images were scanned in three steps-undissected face, hemiface after skinning, and revealing the facial muscles. Student's t-test was used to identify significant differences. Result: The skin and subcutaneous tissue tended to become thicker from the upper to lower and medial to lateral aspects, and the muscles followed the same pattern as that of the most superficial located muscle and the deepest located muscles. No significant sex-related differences were found in the skin at any landmark. However, the muscles tended to be deeper in the female participants. Conclusion: The study data can serve as a basis for creating or enhancing clinical anatomy-based guidelines or improving procedures in the infraorbital region.

Radiographic Comparison of Cranial Tibial Wedge Osteotomy versus Tibial Plateau Leveling Osteotomy: A Cadaveric Study

  • Lee, Jiyoon;Kim, Dongwook;Oh, Hyejong;Lee, Sungin;Choi, Seok Hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.93-99
    • /
    • 2022
  • The present study was performed to compare cranial tibial wedge osteotomy (CTWO) and tibial plateau leveling osteotomy (TPLO) through radiographic evaluation. The experiment was conducted with five cadaver dogs [mean (± SD) weight, 32.9 ± 4.1 kg; mean (± SD) age, 6 ± 2 years; three males and two females] euthanized for reasons unrelated to this study. The cadaver dogs consisted of German Shepherd (n = 3), Belgian Malinois (n = 1), and mixed breed (n = 1). CTWO and TPLO were carried out by the standard surgical method. Radiographic evaluation was performed by comparing several factors, including the flexion and extension angles, the anatomical mechanical axis angle (AMA-angle), tibial length, patellar height measurement using the Labelle-Laurin method, mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), and frontal plane alignment (FPA). Both the CTWO and the TPLO groups showed significantly increased flexion angles after surgery. Only the CTWO group had significantly increased extension angle. Although both groups showed significant decreases in the AMA-angle, the mechanical axis moved cranially against the anatomical axis only in the CTWO group. The patellar height was significantly lowered in the CTWO group. No significant differences were found in mMPTA, mMDTA, or FPA. In conclusion, radiographic comparison revealed more changes in CTWO group than in TPLO group.

Validation of method for chemical treatment of pig carcasses for the control of livestock infectious diseases (가축 전염병 관리를 위한 돼지 사체의 화학적 처리 방법)

  • Oh, Yeonsu;Yoon, Suk Hoon;Tark, Dong-Seob;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.4
    • /
    • pp.283-290
    • /
    • 2021
  • This is a study on the improvement of the chemical treatment method of the livestock carcass treatment newly introduced in the livestock infectious disease prevention method in order to improve the problems of the existing burial-centered carcass treatment method when a livestock infectious disease occurs. It was conducted to establish detailed treatment standards for the chemical treatment method of pig carcasses based on the results of proof of the absence of infectious diseases in pigs. After inoculating pig carcasses with 10 pathogens (6 viruses [FMDV, ASFV, CSFV, PCV2, PRRSV, PEDV] and 4 bacteria [Lawsonia intracellularis, Clostridium perfringens type C, E. coli, Salmonella Typhimurium]) It was treated at 90℃ for 5 hours in a potassium hydroxide (KOH) liquid solution corresponding to 15% of the body weight. This method liquefies all cadaveric components and inactivates all inoculated pathogens. Based on these results, it was possible to prove that chemical treatment of pig carcasses is effective in killing pathogens and is a safe method without the risk of disease transmission. Although there are problems to be solved in the processing and operation of the chemical treatment products of livestock carcasses, the chemical treatment method of livestock carcasses can be suggested as an alternative to the current domestic burial-centered livestock carcass treatment method, preventing environmental pollution, and contributing to public health.

Anatomical Study of the Close Association between Latissimus Dorsi and Surrounding Muscles. How to Safely Harvest the Muscle?

  • Oh, Sangho;Kim, Hyunju;Lee, Jae-Ho;Son, Daegu
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.596-603
    • /
    • 2022
  • Background We suggested an easy and effective harvesting technique to avoid injury to tissues adjacent to the latissimus dorsi (LD). Methods Between 2007 and 2017, breast reconstruction was performed with an LD flap using the "bottom-up" technique. Medical records were retrospectively reviewed. Data on postoperative complications, results, and follow-up were obtained. Nine cadaveric dissections were performed to assess positional relationships between LD and adjacent muscles based on the ribs where relevant muscles and LD attach. Overall, 78 LD flaps were harvested without complications. Results Average age was 45.4 years. The mean operation time was 260minutes. There were no abnormalities or injuries in the adjacent fascia and muscles during the flap harvest. Drains were removed at an average of 21.9 days postoperatively. In all cadavers, there was conjoined fascia between the thoracolumbar and LD fasciae. The average level of the merging point between the LD and external oblique muscle (EOM) was 8.9 to 11.1 ribs. The average level of the overlapping point between the LD and serratus posterior inferior (SPI) was 9.5 to 11.1 ribs. Conclusions There are three dangerous zones during LD flap harvesting. The first zone is where the conjoined fascia encompasses the LD and thoracolumbar fasciae. The second zone is where the LD merges with the EOM and the serratus anterior. The third zone is the lower part where the LD merges with the SPI and EOM. The "bottom-up" technique enables a more meticulous and atraumatic operation by beginner flap surgeons.

Intra-articular replacement of a ruptured cranial cruciate ligament using the Mini-TightRope in the dog: a preliminary study

  • Pinna, Stefania;Lanzi, Francesco;Tassani, Chiara;Mian, Giacomo
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.53.1-53.12
    • /
    • 2020
  • Background: The TightRope System is a device developed to provide extracapsular stabilization of the cranial cruciate ligament (CCL) rupture in canine stifles. I was then also employed for the extra-articular treatment of shoulder instability and for the intra-articular treatment of hip luxation in dogs and cats. Objectives: To evaluate the feasibility of the Mini-TightRope (mTR) System for the intraarticular treatment of CCL rupture in small breed dogs. Methods: A cadaveric canine model was used to record the steps of the surgical procedure. Five client owned dogs weighing from 8 to 10 kg and from 2 to 12 years of age were enrolled in the prospective study in which the mTR device was implanted in the stifle joint to replace the ruptured CCL. The dogs were graded using the Bologna Healing Stifle Injury Index (BHSII) and radiographic osteoarthritis (OA) scores. Results: The outcomes obtained at the time of the surgery (T0) and for the following 12 months (T12) showed an improvement in the functional parameters (BHSII from a median of 74.3 [range, 58.1-82.4] at T0 to 95.6 [range, 94.1-99.3] at T12]). The OA did not change in 3 dogs and increased by only 1 point in 2 dogs. Conclusions: In this preliminary study, the mTR was a successful and repeatable intraarticular surgical procedure for all dogs. Additional studies related to the clinical application of the technique in medium-large dogs should be encouraged.

Comparison of dorsal and medial arthroscopic approach to canine coxofemoral joint: a cadaveric study

  • Sangjun Oh;Jinsu Kang;Namsoo Kim;Suyoung Heo
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.12.1-12.10
    • /
    • 2023
  • Background: Arthroscopic exploration of ventromedial part of canine coxofemoral joint is limited in conventional dorsal approach. Objectives: We evaluated the efficacy of a medial arthroscopic approach to the coxofemoral joint of dogs by analyzing the joint visible area and performing a safety analysis. Methods: Arthroscopic approaches to the coxofemoral joint were made in five cadavers using a traditional (dorsal) and novel (medial) approach. Three observers scored the visible area of images and videos of the acetabulum and femur. A safety analysis was performed via dissection of the medial hind limb. The distance between neurovascular structures and arthroscopic portals was measured. Results: The acetabulum was more visible in the dorsal than in the medial approach, with mean visualization scores of 16 ± 0.00 and 11.83 ± 1.26, respectively. The medioventral side of the femur was significantly more visible in the medial than in the dorsal approach, with mean visualization scores of 3.9 ± 0.99 and 6.93 ± 0.58, respectively. Safety analysis confirmed the medial portal site was safe, provided that the surgeon has comprehensive knowledge of the joint. The minimum distance from the arthroscopic medial portals to the nearest neurovascular structures was 2.5 mm. Conclusions: A medial arthroscopic approach to the canine coxofemoral joint has potential clinical application. Dorsal and medial approaches differ significantly and have distinct purposes. The medial approach is useful to access the ventromedial joint, making it an eligible diagnostic method for an arthroscopic evaluation of this area.