• Title/Summary/Keyword: Cadaver dissection

Search Result 44, Processing Time 0.021 seconds

Positional relationship between the posterior belly of digastric and the stylohyoid variant (붓목뿔근 닿는곳 변이와 두힘살근 사이의 위치관계)

  • Han, Ji Yong;Yoon, Sang-Pil;Chang, In-Youb
    • Journal of Medicine and Life Science
    • /
    • v.15 no.1
    • /
    • pp.12-15
    • /
    • 2018
  • Digastric and stylohyoid muscles are located in the suprahyoid region. There have been few studies about the general morphology of stylohyoid muscle and its relationship with digastric muscle. During routine educational dissection, unusual insertion of bilateral stylohyoid muscle was found in the cadaver of a 92-year-old Korean male, whose cause of death was 'aspiration pneumonia'. Stylohyoid muscle arose from the styloid process, and inserted onto the intermediate tendon of digastric muscle and the hyoid bone on both sides. Each digastric muscle normally consists of an anterior belly, intermediate tendon and a posterior belly. In this cadaver, there were two anterior bellies on right side while one anterior belly was found on left side. Stylohyoid muscle ran medial to the intermediate tendon of digastric muscle on both sides. The anatomical relationship between stylohyoid and digastric muscles was reviewed based on morphological and embryological point of view.

Bilateral unusual branching pattern of the external carotid artery in a human cadaver

  • Stefan Trifonov;Miroslav Dobrev;Preslava Hristova;Iren Bogeva-Tsolova
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.316-319
    • /
    • 2024
  • Comprehensive understanding of the variations in the branching of the external carotid artery (ECA) is essential to minimizing vascular complications during cranio-facial and neck surgical procedures. We demonstrate a rare case of unusual branching of ECAs in both carotid triangles and anomalous origin of the left ascending pharyngeal artery (APA) during dissection of embalmed cadaver. The right and left common carotid arteries (CCA) bifurcated at the level of the upper border of the thyroid cartilage. The right superior thyroid artery (STA) originated anterior to the carotid bifurcation (CB), while the left STA originated from the anterior aspect of the left CCA. The right ECA trifurcated into linguofacial trunk, APA, and distal ECA, 15.7 mm from CB. On the left side, lingual artery and APA arose as a short common linguopharyngeal trunk, 1.9 mm from CB. The left facial and occipital arteries originated anteromedially and posteriorly at the same level.

Case Study on Osteology Practice at Human Anatomy Course: Focused on the Students in the Department of Biomedical Laboratory Science (인체해부학 수업에서 골학실습의 활용 사례 연구: 임상병리학과 학생을 중심으로)

  • Kim, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.4
    • /
    • pp.144-152
    • /
    • 2016
  • This study was conducted for the first time based on the evidence that cadaver practice is not easy in the university without medical school where cadaver dissection is not easy to look for. The purpose of this study was to evaluate the effect of osteology practice at human anatomy course for students at the freshman stage in college of health science without medical school. Both self report questionnaires and evaluation paper were analyzed depending on the course of higher education and gender. As a result of analysis, most students thought that osteology practice was interesting and it helped to understand of anatomy lecture. But students from liberal arts had poor understanding of bone's direction compared with students from natural sciences. And most students wanted to do cadaver dissectionafter osteology practice. In conclusion, osteology practice was recommended to student's expectation as well as education of gross anatomy in department of biomedical laboratory science, collage of health science without medical school. This study suggested that practice of gross anatomy should run parallel with lecture.

Temple and Postauricular Dissection in Face and Neck Lift Surgery

  • Lee, Joo Heon;Oh, Tae Suk;Park, Sung Wan;Kim, Jae Hoon;Tansatit, Tanvaa
    • Archives of Plastic Surgery
    • /
    • v.44 no.4
    • /
    • pp.261-265
    • /
    • 2017
  • Periauricular paresthesia may afflict patients for a significant amount of time after facelift surgery. When performing face and neck lift surgery, temple and posterior auricular flap dissection is undertaken directly over the auriculotemporal, great auricular, and lesser occipital nerve territory, leading to potential damage to the nerve. The auriculotemporal nerve remains under the thin outer superficial fascia just below the subfollicular level in the prehelical area. To prevent damage to the auriculotemporal nerve and to protect the temporal hair follicle, the dissection plane should be kept just above the thin fascia covering the auriculotemporal nerve. Around the McKinney point, the adipose tissue covering the deep fascia is apt to be elevated from the deep fascia due to its denser fascial relationship with the skin, which leaves the great auricular nerve open to exposure. In order to prevent damage to the posterior branches of the great auricular nerve, the skin flap at the posterior auricular sulcus should be elevated above the auricularis posterior muscle. Fixating the superficial muscular aponeurotic system flap deeper and higher to the tympano-parotid fascia is recommended in order to avoid compromising the lobular branch of the great auricular nerve. The lesser occipital nerve (C2, C3) travels superficially at a proximal and variable level that makes it vulnerable to compromise in the mastoid dissection. Leaving the adipose tissue at the level of the deep fascia puts the branches of the great auricular nerve and lesser occipital nerve at less risk, and has been confirmed not to compromise either tissue perfusion or hair follicles.

Revision of Lateral Arm Free Flap; Can It be a Substituete for Radial Forearm Free Flap? (외측상박 유리피판의 유용성에 관한 재조명; 전박부 유리피판을 대체할 수 있는가?)

  • Ahn, Hee-Chang
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.80-86
    • /
    • 1997
  • The lateral arm flap was reported first by Song et al. in 1982, and Katsaros and colleagues described an anatomic study and clinical cases in 1984. This flap is thin, has relatively constant vascular anatomy, and provides relatively acceptable scar at the donor site. Despite its many advantages its wide application has been limited by its short vascular pedicle with small diameter of lumen, and its small skin paddle. We studied its anatomical structure to get longer length of vascular pedicle, wide diameter and thinner part of flap beyond the lateral condyle through 6 fresh cadaver dissection and dye injection study. We experienced 21 cases of lateral arm free flaps and 26 cases of forearm free flaps from May, 1992 to January, 1996. We compared its usefulness with forearm free flaps in the aspects of donor morbidity, operative factors, quality of flap, and versatility. In conclusion, lateral arm flap can replace the role of forearm flap in most cases so that patient's donor morbidity can be reduced especially in the women.

  • PDF

The Present Situation and Problems of Human Anatomy in Oriental Medicine (한의학에서 사람해부학 교육의 현황과 문제점)

  • Kim, Soo-Myung
    • Journal of Haehwa Medicine
    • /
    • v.5 no.2
    • /
    • pp.445-448
    • /
    • 1997
  • The human anatomy is the fundamental subject which is required lots of time and efforts for medical students. But most of the oriental medical students think it little important field. And moreover they have no active attitudes in their courses. In order to improve the present situation, the results obtained from this study are as follows: 1. As a Law of Cadaver Conservation revised systemically, there's need to have enough cadavers for dissection. 2. The teaching method must be converted into the laboratory technique with the strengthening human anatomy. 3. With opening a neuroanatomy course in oriental medical curriculum, the quality of nervous system is expected to increase. 4. Under the current medical system, there's need to have discussion deeply about the histology course.

  • PDF

Multiple renal veins clogging the hilum of the right kidney

  • Satheesha B Nayak;Narendra Pamidi;Vasanthakumar Packirisamy;Soumya Kodimajalu Vasudeva
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.141-144
    • /
    • 2023
  • Knowledge of variations of renal vessels is of utmost importance in retroperitoneal surgeries and kidney transplant surgeries. We report concurrent variations of the right renal vessels, observed in an adult male cadaver during dissection classes. The right kidney was supplied by three renal arteries, out of which two entered the kidney through the hilum and the other one entered through the lower pole of the kidney. There were five renal veins, emerging independently from the hilum and opening separately through five openings into the inferior vena cava. Among the veins, only one emerged anterior to the renal pelvis and the other four emerged behind it. Four of them terminated into the posterolateral aspect of the inferior vena cava, whereas one terminated into its anterior aspect. Fourth vein from above, received the right testicular vein. The renal hilum was clogged with the presence of seven vessels and renal pelvis.

Anatomical variation of quadratus plantae in relation with flexor digitorum brevis

  • Punnapa Raviteja;Mrudula Chandrupatla;Ramoju Harshitha;Marni Sameer Chowdary
    • Anatomy and Cell Biology
    • /
    • v.56 no.4
    • /
    • pp.562-565
    • /
    • 2023
  • The muscles of the sole have been traditionally categorized into four layers, but it is more practical to divide them into peripheral and central groups. The peripheral groups include medial and lateral groups. The central plantar muscles are more numerous and divided into superficial and deep layers. During routine dissection in the Department of Anatomy, All India Institute of Medical Sciences Bibinagar, Hyderabad, variations are been observed in the plantar intrinsic muscle in the left foot & right foot of a 53-year-old male cadaver. This is the first cadaveric report of a combination of discrepancies especially the inter-tendinous connection between quadratus plantae and flexor digitorum brevis. Similar observations in the literature were not found by us. It is important to identify and study these dissimilarities of muscles of the sole for surgeons, anatomists, radiologists and orthopaedics as these muscles and tendons are used in foot reconstructive procedures, and for the treatment of some congenital anomalies.

Robot-Assisted Transoral Odontoidectomy : Experiment in New Minimally Invasive Technology, a Cadaveric Study

  • Yang, Moon-Sul;Yoon, Tae-Ho;Yoon, Do-Heum;Kim, Keung-Nyun;Pennant, William;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.248-251
    • /
    • 2011
  • Objective : In the field of spinal surgery, a few laboratory results or clinical cases about robotic spinal surgery have been reported. In vivo trials and development of related surgical instruments for spinal surgery are required before its clinical application. We investigated the use of the da $Vinci^{(R)}$ Surgical System in spinal surgery at the craniovertebral junction in a human cadaver to demonstrate the efficacy and pitfalls of robotic surgery. Methods : Dissection of pharyngeal wall to the exposure of C1 and odontoid process was performed with full robotic procedure. Although assistance of another surgeon was necessary for drilling and removal of odontoid process due to the lack of appropriate end-effectors, successful robotic procedures for dural sutures and exposing spinal cord proved its safety and dexterity. Results : Robot-assisted odontoidectomy was successfully performed in a human cadaver using the da $Vinci^{(R)}$ Surgical System with few robotic arm collisions and minimal soft tissue damages. Da $Vinci^{(R)}$ Surgical System manifested more dexterous movement than human hands in the deep and narrow oral cavity. Furthermore, sutures with robotic procedure in the oral cavity demonstrated the advantage over conventional procedure. Conclusion : Presenting cadaveric study proved the probability of robot-assisted transoral approach. However, the development of robotic instruments specific to spinal surgery must first precede its clinical application.

A Cadaveric Study of Thread Cubital Tunnel Release with Newly Developed Threads

  • Kang, Minsuk;Nam, Yong Seok;Kim, In Jong;Park, Hae-Yeon;Ham, Jung Ryul;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.307-314
    • /
    • 2022
  • Objective : The percutaneous thread transection technique is a surgical dissecting method using a dissecting thread inserted through a needle under ultrasound guidance without skin incision. As the new dissecting threads were developed domestically, this cadaver study was conducted to compare the effectiveness and safety between the new threads (ultra V sswire and smartwire-01) and a pre-existing commercial dissecting thread (loop & shear) by demonstrating a modified looped thread cubital tunnel release. Methods : The percutaneous cubital tunnel release procedure was performed on 29 fresh cadaveric upper extremities. The pre-existing commercial thread was used in 5 upper extremities. The two newly developed threads were used in 24 upper extremities. Two practitioners performed the procedures separately. After the modified looped thread cubital release, anatomical and histological analyses were performed by a blinded anatomist. The presence of the dissected cubital tunnel and damaged adjacent soft tissue was assessed. Results : Out of the 29 cadaveric upper extremities, 27 specimens showed complete dissection of the Osborne ligament and the proximal fascia of the flexor carpi ulnaris muscle. One specimen was incompletely dissected in each of the ultra V sswire and smartwire-01 groups. There were no injuries of adjacent structures including the ulnar nerve, ulnar artery, medial antebrachial cutaneous nerve, or flexor tendon with either the commercial thread or the newly developed threads. The anatomical analysis revealed clear and sharp incisional margins of the cubital tunnel in the Smartwire-01 and loop & shear groups. All three kinds of threads maintained proper linear elasticity for easy handling during the procedure. The smartwire-01 provided higher visibility in ultrasound than the other threads. Conclusion : The newly developed threads were effective and safe for use in the thread cubital tunnel release procedure.