• 제목/요약/키워드: Cable-stayed concrete bridge

검색결과 89건 처리시간 0.03초

Concrete arch bridges built by lattice cantilevers

  • Granata, Michele Fabio;Margiotta, Piercarlo;Recupero, Antonino;Arici, Marcello
    • Structural Engineering and Mechanics
    • /
    • 제45권5호
    • /
    • pp.703-722
    • /
    • 2013
  • In this paper a study about concrete arch bridges built by lattice cantilevers is presented. Lattice cantilevers are partial structures composed of deck, arch, piers and provisional steel diagonals, organized as reticular cantilever girders, in order to build arch bridges without the use of centrings, supports or temporary towers. Characteristics of this construction methodology with its variants are explained together with their implications in the erection sequence. Partial elastic scheme method is implemented in order to find initial forces of temporary cables and a forward analysis is carried out to follow the actual sequence of construction, by extending a procedure already applied to concrete cable-stayed bridges and to arches built by the classical suspended cantilever method. A numerical application on a case-study of a concrete arch bridge is performed together with a comparison between different methodologies followed for its construction sequence. Differences between erection by lattice cantilevers and cable-stayed cantilevers, are discussed. Results can be useful for designers in conceptual design of concrete arch bridges.

Soil-structure-foundation effects on stochastic response analysis of cable-stayed bridges

  • Kuyumcu, Zeliha;Ates, Sevket
    • Structural Engineering and Mechanics
    • /
    • 제43권5호
    • /
    • pp.637-655
    • /
    • 2012
  • In this study, stochastic responses of a cable-stayed bridge subjected to the spatially varying earthquake ground motion are investigated by the finite element method taking into account soil-structure interaction (SSI) effects. The considered bridge in the analysis is Quincy Bay-view Bridge built on the Mississippi River in between 1983-1987 in Illinois, USA. The bridge is composed of two H-shaped concrete towers, double plane fan type cables and a composite concrete-steel girder deck. In order to determine the stochastic response of the bridge, a two-dimensional lumped masses model is considered. Incoherence, wave-passage and site response effects are taken into account for the spatially varying earthquake ground motion. Depending on variation in the earthquake motion, the response values of the cable-stayed bridge supported on firm, medium and soft foundation soil are obtained, separately. The effects of SSI on the stochastic response of the cable-stayed bridge are also investigated including foundation as a rigidly capped vertical pile groups. In this approach, piles closely grouped together beneath the towers are viewed as a single equivalent upright beam. The soil-pile interaction is linearly idealized as an upright beam on Winkler foundation model which is commonly used to study the response of single piles. A sufficient number of springs on the beam should be used along the length of the piles. The springs near the surface are usually the most important to characterize the response of the piles surrounded by the soil; thus a closer spacing may be used in that region. However, in generally springs are evenly spaced at about half the diameter of the pile. The results of the stochastic analysis with and without the SSI are compared each other while the bridge is under the sway of the spatially varying earthquake ground motion. Specifically, in case of rigid towers and soft soil condition, it is pointed out that the SSI should be significantly taken into account for the design of such bridges.

FRP-콘크리트 합성 바닥판의 사장교 적용 (Application of FRP-Concrete Composite Deck to Cable Stayed Bridge)

  • 조근희;박성용;김성태;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.217-220
    • /
    • 2008
  • FRP-콘크리트 합성 바닥판을 개선하여 사장교에 경제적으로 적용 가능한 바닥판을 개발하고, 이의 설계 및 경제성 등을 제시한다. 기존의 FRP-콘크리트 합성 바닥판은 탄성계수가 낮은 GFRP 패널의 채용으로 인하여 낮은 단면 강성을 갖게 되는데, 이는 바닥판의 처짐 등과 같은 사용성 문제를 야기할 수 있다. 그래서 기존 FRP-콘크리트 합성 바닥판의 양단을 콘크리트로 감싸서 순지간이 줄어드는 효과를 얻을 수 있는 프리캐스트 FRP-콘크리트 바닥판을 고안하였다. 이 바닥판은 기존 바닥판에 비해 바닥판 지간은 늘어나면서 자중은 크게 늘지 않는 장점을 가진다. 이러한 개선된 바닥판에 대해 거더와 합성하는 경우, 거더 위에서 단순지지하는 경우로 나누어 단면 최적화를 수행하였다. 최적화된 바닥판을 중앙지간 540m인 사장교에 적용한 결과, 상부구조 및 케이블 물량의 감소 효과를 얻을 수 있어 경제적으로 적용될 수 있음을 확인하였다.

  • PDF

최적신뢰성에 의한 강합성 복합사장교의 확률적 위험도평가 (Probabilistic Risk Assessment of a Steel Composite Hybrid Cable-Stayed Bridge Based on the Optimal Reliabilities)

  • 윤정현;조효남
    • 한국강구조학회 논문집
    • /
    • 제19권4호
    • /
    • pp.395-402
    • /
    • 2007
  • 허용응력설계법과 강도설계법으로 설계된 강합성 플레이트 보강형과 콘크리트 보강형으로 구성된 장대교량인 복합사장교의 확률적 위험도 평가를 수행하였다. 최대 축력, 전단력 및 정 부모멘트 발생단면에 기초한 위험단면에 대해 AFOSM 알고리즘과 시뮬레이션기법을 사용하여 케이블, 주탑, 보강형 및 강-콘크리트 접합부의 요소신뢰성을 평가하였다. 체계신뢰성해석을 위해, 케이블, 주탑 및 콘트리트와 강합성 보강형으로 구성된 복합사장교의 시스템을 조합 파괴모드로 모델링하였으며, 이를 통해 전체 구조시스템의 파괴확률과 신뢰성지수를 산출하였다. 본 연구를 통해 복합사장교의 거동특성에 기초한 파괴모드를 제안하였고 위험도평가 방법으로서 부분 ETA기법의 효용성을 확인하였다.

Spatially variable effects on seismic response of the cable-stayed bridges considering local soil site conditions

  • Tonyali, Zeliha;Ates, Sevket;Adanur, Suleyman
    • Structural Engineering and Mechanics
    • /
    • 제70권2호
    • /
    • pp.143-152
    • /
    • 2019
  • In this study, stochastic responses of a cable-stayed bridge subjected to the spatially varying earthquake ground motion are investigated for variable local soil cases and wave velocities. Quincy Bay-view cable-stayed bridge built on the Mississippi River in Illinois, USA selected as a numerical example. The bridge is composed of two H-shaped concrete towers, double plane fan type cables and a composite concrete-steel girder deck. The spatial variability of the ground motion is considered with the coherency function, which is represented by the components of incoherence, wave-passage and site-response effects. The incoherence effect is investigated by considering Harichandran and Vanmarcke model, the site-response effect is outlined by using hard, medium and soft soil types, and the wave-passage effect is taken into account by using 1000, 600 and 200 m/s wave velocities for the hard, medium and soft soils, respectively. Mean of maximum response values obtained from the analyses are compared with those of the specific cases of the ground motion model. It is concluded that the obtained results from the bridge model increase as the differences between local soil conditions cases of the bridge supports change from firm to soft. Moreover, the variation of the wave velocity has important effects on the responses of the deck and towers as compared with those of the travelling constant wave velocity case. In addition, the variability of the ground motions should be considered in the analysis of long span cable-stayed bridges to obtain more accurate results in calculating the bridge responses.

현장 풍속 특성을 반영한 콘크리트 사장교의 버페팅 응답 (Buffeting Responses of Concrete Cable-stayed Bridge Considering Turbulent Characteristics of Bridge Site)

  • 김성호;임성순;권순덕
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.97-104
    • /
    • 2011
  • 본 연구에서는 교량 현장에서 계측한 풍속 스펙트럼을 풍동에서 구현하고, 콘크리트 사장교를 대상으로 공력 어드미턴스함수를 측정하였다. 그리고 현장 측정한 난류 특성을 바탕으로 콘크리트 사장교의 3차원 버페팅 해석을 수행하였다. 본 연구의 결과를 보면 적절히 공력 어드미턴스함수를 고려할 경우에 고려하지 않은 경우보다 버페팅 응답이 절반 가까이 줄어드는 것으로 나타났다. 그리고 격자난류를 사용할 경우에 저주파 영역에서 공력 어드미턴스 함수가 낮아서 풍하중을 과소평가할 가능성이 있는 것으로 나타났다. 공력 어드미턴스 함수가 버페팅 응답에 미치는 영향이 상당하므로 향후 교량의 버페팅 해석시 플러터계수나 능동난류로부터 추출한 공력 어드미턴스 함수를 사용할 것을 추천한다.

Optimum design of cable-stayed bridges

  • Long, Wenyi;Troitsky, Michael S.;Zielinski, Zenon A.
    • Structural Engineering and Mechanics
    • /
    • 제7권3호
    • /
    • pp.241-257
    • /
    • 1999
  • This paper presents a procedure to minimize the cost of materials of cable-stayed bridges with composite box girder and concrete tower. Two sets of iterations are included in the proposed procedure. The first set of iteration performs the structural analysis for a cable-stayed bridge. The second set of iteration performs the optimization process. The design is formulated as a general mathematical problem with the cost of the bridge as the objective function and bending forces, shear forces, fatigue stresses, buckling and deflection as constraints. The constraints are developed based on the Canadian National Standard CAN/CSA-S6-88. The finite element method is employed to perform the complicated nonlinear structural analysis of the cable-stayed bridges. The internal penalty function method is used in the optimization process. The limit states design method is used to determine the load capacity of the bridge. A computer program written in FORTRAN 77 is developed and its validity is verified by several practical-sized designs.

사장교의 내풍해석을 통한 인명보호 구조물의 내하능력평가 (Load-carrying Capacities of Safety Structures on Wind-resistant Analyses of Cable-stayed Bridge)

  • 허택녕
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.587-594
    • /
    • 2022
  • In the 2000s, a lot of cable-type grand bridges are being built in consideration of economic aspects such as the reduction of logistics costs and the distribution of traffic volume due to rapid economic development. In addition, because the recently installed grand bridges are designed in an aesthetic form that matches the surrounding environment as well as the original function of the road bridge, and serves as a milestone in an area and is used as an excellent tourism resource, attracting many vehicles and people, there is an urgent need for a safety structure that can ensure the safety of not only vehicles but also people. In order to make cable-stayed bridge safe on wind for additional five safety structures, main girder models with and without safety structures for wind-tunnel experiments was made, and wind tunnel experiments was carried out to measure aerodynamic force coefficients. Also, wind-resistant analyses of 3D cable-stayed bridge were performed on the basis of wind-tunnel experiment results. From the wind tunnel experiments for the aerodynamic force coefficients of main girder with five safety structures and the wind resistant analyses of cable-stayed bridge without safety structure and with safety structure, it was concluded that the best form of wind-resistant safety was shown in the order of mesh, standard, bracing, hollow, and closed type. And wind-resistant safety of cable-stayed bridge with hollow and closed type on design wind speed 68.0m/sec was not secured. Finally, as five safety structures are installed, maximum rate of stress increments was shown in the order of steel main beam, steel floor beam, concrete floor beam and cables.

Seismic performance of a fiber-reinforced plastic cable-stayed bridge

  • Hodhod, Osama A.;Khalifa, Magdi A.
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.399-414
    • /
    • 1997
  • This paper presents an investigation into the seismic response characteristics of a proposed ligh-weight pedestrian cable-stayed bridge made entirely from Glass Fiber Reinforced Plastics(GFRP). The study employs three dimensional finite element models to study and compare the dynamic characteristics and the seismic response of the GFRP bridge to a conventional Steel-Concrete (SC) cable-stayed bridge alternative. The two bridges were subjected to three synthetic earthquakes that differ in the frequency content characteristics. The performance of the GFRP bridge was compared to that of the SC bridge by normalizing the live load and the seismic internal forces with respect to the dead load internal forces. The normalized seismically induced internal forces were compared to the normalized live load internal forces for each design alternative. The study shows that the design alternatives have different dynamic characteristics. The light GFRP alternative has more flexible deck motion in the lateral direction than the heavier SC alternative. While the SC alternative has more vertical deck modes than the GFRP alternative, it has less lateral deck modes than the GFRP alternative in the studied frequency range. The GFRP towers are more flexible in the lateral direction than the SC towers. The GFRP bridge tower attracted less normalized base shear force than the SC bridge towers. However, earthquakes, with peak acceleration of only 0.1 g, and with a variety of frequency content could induce high enough seismic internal forces at the tower bases of the GFRP cable-stayed bridge to govern the structural design of such bridge. Careful seismic analysis, design, and detailing of the tower connections are required to achieve satisfactory seismic performance of GFRP long span bridges.

Seismic design strategy of cable stayed bridges subjected to strong ground motions

  • Xu, Yan;Duan, Xinzhi;Li, Jianzhong
    • Structural Engineering and Mechanics
    • /
    • 제51권6호
    • /
    • pp.909-922
    • /
    • 2014
  • In this paper, we present an alternative seismic design strategy for cable stayed bridges with concrete pylons when subjected to strong ground motions. The comparison of conventional seismic design using supplemental dampers (strategy A) and the new strategy using nonlinear seismic design of pylon columns (strategy B) is exemplified by one typical medium span cable stayed bridge subjected to strong ground motions from 1999 Taiwan Chi-Chi earthquake and 2008 China Wenchuan earthquake. We first conducted the optimization of damper parameters according to strategy A in response to the distinct features that strong ground motions contain. And then we adopted strategy B to carry out seismic analysis by introducing the elastic-plastic elements that allowing plasticity development in the pylon columns. The numerical results show that via strategy A, the earthquake induced structural responses can be kept in the desired range provided with the proper damping parameters, however, the extra cost of unusual dampers will be inevitable. For strategy B, the pylon columns may not remain elastic and certain plasticity developed, but the seismic responses of the foundation will be greatly decreased, meanwhile, the displacement at the top of pylon seems to be not affected much by the yielding of pylon columns, which indicates the pylon nonlinear design can be an alternative design strategy when strong ground motions have to be considered for the bridge.