• Title/Summary/Keyword: Cable joint

Search Result 198, Processing Time 0.023 seconds

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho, Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.357-364
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. Specimen obtained 1mm thickness from the insulation of real power cable and cable joint. <중략>The partial discharges are measured to determine their time dependence for 60 minutes and the influence of applied electrical stress under 30kV. $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Experimental and numerical study on tensile capacity of composite cable-girder anchorage joint

  • Xuefei Shi;Yuzhuo Zhong;Haiying Ma;Ke Hu;Zhiquan Liu;Cheng Zeng
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.215-230
    • /
    • 2023
  • Cable-girder anchorage joint is the critical part of cable-supported bridges. Tensile-plate anchorage (TPA) is one of the most commonly used types of cable-girder anchorage joints in steel girder cable-supported bridges. In recent years, it has been proposed by bridge designers to apply TPA to concrete girder cable-supported bridges to form composite cable-girder anchorage joint (CCGAJ). In this paper, the mechanical performance of CCGAJ under tensile force is studied through experimental and numerical analyses. Firstly, the effects of the external prestressing (EP) and the bearing plate (BP) on the mechanical performance of CCGAJ were investigated through three tests. Then, finite element model was established for parametrical study, and was verified by the experimental results. Then, the effects of shear connector forms, EP, BP, vertical rebar rate, and perforated rebar rate on the tensile capacity of CCGAJ were investigated through numerical analyses. The results show that the tensile capacity of CCGAJ depends on the first row of PR. The failure mode of CCGAJ using headed stud connectors is to form a shear failure surface at the end of the studs while the failure mode using PBLs is similar to the bending of a deep girder. Finally, based on the strut-and-tie model (STM), a calculation method for CCGAJ tensile capacity was proposed, which has a high accuracy and can be used to calculate the tensile capacity of CCGAJ.

Structural behavior of the suspen-dome structures and the cable dome structures with sliding cable joints

  • Liu, Hongbo;Chen, Zhihua
    • Structural Engineering and Mechanics
    • /
    • v.43 no.1
    • /
    • pp.53-70
    • /
    • 2012
  • Sliding cable joints have been developed for the cable dome structures and the suspen-dome structures to reduce the cable pre-stressing loss and obtain a uniform inner force in each hoop cable. However, the relevant investigation is less addressed on the structural behavior of the cable dome structures and the suspen-dome structures with sliding cable joints due to the lack of analysis techniques. In this paper, a closed sliding polygonal cable element was established to analyze the structural behavior of the cable dome structures and the suspen-dome structures with sliding cable joints. The structural behaviors with sliding cable joints were obtained.

Long-term condition monitoring of cables for in-service cable-stayed bridges using matched vehicle-induced cable tension ratios

  • Peng, Zhen;Li, Jun;Hao, Hong
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.167-179
    • /
    • 2022
  • This article develops a long-term condition assessment method for stay cables in cable stayed bridges using the monitored cable tension forces under operational condition. Based on the concept of influence surface, the matched cable tension ratio of two cables located at the same side (either in the upstream side or downstream side) is theoretically proven to be related to the condition of stay cables and independent of the positions of vehicles on the bridge. A sensor grouping scheme is designed to ensure that reliable damage detection result can be obtained even when sensor fault occurs in the neighbor of the damaged cable. Cable forces measured from an in-service cable-stayed bridge in China are used to demonstrate the accuracy and effectiveness of the proposed method. Damage detection results show that the proposed approach is sensitive to the rupture of wire damage in a specific cable and is robust to environmental effects, measurement noise, sensor fault and different traffic patterns. Using the damage sensitive feature in the proposed approach, the metrics such as accuracy, precision, recall and F1 score, which are used to evaluate the performance of damage detection, are 97.97%, 95.08%, 100% and 97.48%, respectively. These results indicate that the proposed approach can reliably detect the damage in stay cables. In addition, the proposed approach is efficient and promising with applications to the field monitoring of cables in cable-stayed bridges.

Partial Discharge Characteristics of the XLPE/EPDM Interface in Power Cable Joint (전력케이블 접속재 XLPE/EPDM 계면의 부분방전 특성)

  • Cho, Kyung-Soon;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.780-786
    • /
    • 2007
  • This paper describes the influence on partial discharge characteristics of defects at the model XLPE/EPDM interfaces of power cable joints. The defects of void and copper which could inadvertently be present at the joint interface. We measured ${\Phi}-n,\;{\Phi}-q$ patterns by a computer-aided partial discharge measuring system. Several parameters i, e, maximum discharge $q_{max}$ [pC], average discharge q [pC/cycle], and average angle of discharge ${\Theta}g$ [deg] were found to depend upon the defect type varying applied voltage. As the result of time evaluation, partial discharges are small different at copper defects, but is decreasing obviously about 20 minutes at void defect. It considered that difference of magnitude of total positive discharge of Q+ [pC] and total negative discharge of Q- [pC] is SPMD(swarming pulsive micro discharges).

A Study on the Predictive Diagnosis of the Cable Joint Using Ultrasonic Technique (초음파 측정기법을 사용한 케이블 접속부 예방진단 연구)

  • 곽희로;이동준;박동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.78-84
    • /
    • 2000
  • In this paper, the diagnosis technique was proposed by measuring and analyzing ultrasonic signals caused by partial discharge on the interface of cable joint. The measured ultrasonic signal was filtered by wavelet transform, and then the dominant signal of filtered signal was analyzed by fast fourier transform(FFT). As a result, it was confirmed that different characteristics were obtained with the moisture and the metal powder on the interface of cable joint and with voltage increment.

  • PDF

Study on the unidirectional compaction of terminal cables in the CICC joint

  • 남현일;이호진;박재학;홍계원
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.218-223
    • /
    • 2002
  • The void volume fraction of cables is one of the effective parameters to characterize the joints of superconducting magnet. Because electrical resistance and cooling stability in the CICC (Cable-in-Conduit Conductors) joint are governed by the void volume fraction, it should be controlled constantly in the termination of cable. The change of cross-section shape in the cable was fecund during the unidirectional compaction of terminal sleeve. The non-uniform thickness of the sleeve after compaction is expected because the loading is not taxi-symmetric, and the plastic flow is also not axi-symmetric. The CICC was compacted from 45% void volume fraction to 15% by using two-piece compaction jig, which could be pressed mini-directionally. Commercial code, ABAQUS, was used to analyze the plastic flow in the sleeve during the unidirectional compaction. The increment of radius of curvature of compaction jig could minimize the change of the deformed shape of cables. The calculated results were agreed with the experimental observations.

  • PDF

Protection of Insulation Joint Box and Analysis of Overvoltage in Underground Power Cable Systems (지중송전케이블계통에서 절연통 보호대책 및 과전압 해석)

  • Hong, Dong-Suk;Jin, Hye-Young;Jung, Che-Kyun;Lee, Jong-Beom;Cho, Han-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.380-382
    • /
    • 2001
  • This paper describes the protection of insulation joint box in combined transmission line which is connected with the 154kV underground power cables. An actual power cable system was selected to establish modeling and to analyze. Modeling was established in EMTP and ATPDraw. Simulation was carried out according to the buried method of cable and connection method of CCPU. Results presented in this paper will be applied to another power cable systems.

  • PDF

Research on the cable-driven endoscopic manipulator for fusion reactors

  • Guodong Qin;Yong Cheng;Aihong Ji;Hongtao Pan;Yang Yang;Zhixin Yao;Yuntao Song
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.498-505
    • /
    • 2024
  • In this paper, a cable-driven endoscopic manipulator (CEM) is designed for the Chinese latest compact fusion reactor. The whole CEM arm is more than 3000 mm long and includes end vision tools, an endoscopic manipulator/control system, a feeding system, a drag chain system, support systems, a neutron shield door, etc. It can cover a range of ±45° of the vacuum chamber by working in a wrap-around mode, etc., to meet the need for observation at any position and angle. By placing all drive motors in the end drive box via a cable drive, cooling, and radiation protection of the entire robot can be facilitated. To address the CEM motion control problem, a discrete trajectory tracking method is proposed. By restricting each joint of the CEM to the target curve through segmental fitting, the trajectory tracking control is completed. To avoid the joint rotation angle overrun, a joint limit rotation angle optimization method is proposed based on the equivalent rod length principle. Finally, the CEM simulation system is established. The rationality of the structure design and the effectiveness of the motion control algorithm are verified by the simulation.

Development of Accessories for 345kV XLPE Cable with Small Size Conductor (345kV XLPE 소도체 Cable용 접속함의 개발)

  • Kim, H.J;Kim, K.Y;Park, J.K.;Song, J.H.;Shin, H.D.;Park, K.L.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1775-1777
    • /
    • 2004
  • Taihan Electric Wire Co. developed accessories(PJ, EB-G, EB-A, EB-O) for 345kV XLPE $1C{\times}600mm^2$ cable as a small size conductor cable, after installed 345kV XLPE $1C{\times}600mm^2$ cable, PJ and EB-G on Youngseo${\sim}$Youngdeungpo project KEPCO planed in 2003. All of 345kV XLPE $1C{\times}600mm^2$ cable Accessories are finished the type tests successfully. Straight joint as a Prefabricated Joint(PJ) had shorter the days of assembling than those of TMJ used on the 154kV XLPE Cable. Particularly, the use of clean booth to prevent the dusts and the penetration of water also had made the quality of jointing improved.

  • PDF