• 제목/요약/키워드: Cable damage

검색결과 210건 처리시간 0.048초

Damage detection of bridges based on spectral sub-band features and hybrid modeling of PCA and KPCA methods

  • Bisheh, Hossein Babajanian;Amiri, Gholamreza Ghodrati
    • Structural Monitoring and Maintenance
    • /
    • 제9권2호
    • /
    • pp.179-200
    • /
    • 2022
  • This paper proposes a data-driven methodology for online early damage identification under changing environmental conditions. The proposed method relies on two data analysis methods: feature-based method and hybrid principal component analysis (PCA) and kernel PCA to separate damage from environmental influences. First, spectral sub-band features, namely, spectral sub-band centroids (SSCs) and log spectral sub-band energies (LSSEs), are proposed as damage-sensitive features to extract damage information from measured structural responses. Second, hybrid modeling by integrating PCA and kernel PCA is performed on the spectral sub-band feature matrix for data normalization to extract both linear and nonlinear features for nonlinear procedure monitoring. After feature normalization, suppressing environmental effects, the control charts (Hotelling T2 and SPE statistics) is implemented to novelty detection and distinguish damage in structures. The hybrid PCA-KPCA technique is compared to KPCA by applying support vector machine (SVM) to evaluate the effectiveness of its performance in detecting damage. The proposed method is verified through numerical and full-scale studies (a Bridge Health Monitoring (BHM) Benchmark Problem and a cable-stayed bridge in China). The results demonstrate that the proposed method can detect the structural damage accurately and reduce false alarms by suppressing the effects and interference of environmental variations.

YBCO 박막형 선재를 이용한 초전도 전류제한기의 연계에 따른 고온 초전도 케이블의 사고전류 통전 특성에 관한 연구 (Study on Transport Current Properties of HTS cable connected with SFCL by using YBCO Thin Film type wire)

  • 이동혁;김용진;한병성;두호익;한상철;이정필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.43-43
    • /
    • 2010
  • HTS(High Temperature Superconductor) cable has a high possibility of practical use due to the possibility of low voltage and high capacity transmission caused by its lower power loss than copper cable. On the other hand, when fault current occurred, resistance increase caused by superconductivity loss, the amount of power supplies has diminished, furthermore, it's necessary to take the possible danger of damage to HITS cable into account. Therefore, an effective plan for dealing with the above problem is to link HITS cable to SFCL. In this study, we researched the possibilities of normal transport current as well as the safety of HITS cable by analyzing the properties of transport current in HITS cable connected with SFCL.

  • PDF

Damage prevention and aerodynamics of cable-stayed bridges in heavy snowstorms: A case study

  • Mladen, Bulic;Mehmed, Causevic
    • Structural Engineering and Mechanics
    • /
    • 제85권1호
    • /
    • pp.81-88
    • /
    • 2023
  • This paper begins by analyzing cable vibrations due to external excitations and their effects on the overall dynamic behavior of cable-stayed bridges. It is concluded that if the natural frequency of a cable approaches any natural frequency of the bridge, the cable loses its rigidity and functionality. The results of this analysis explain the phenomenon that occurred on the Dubrovnik Bridge in Croatia during a storm and measures for its retrofit. A field test was conducted before the bridge was opened to traffic. It was concluded: "The Bridge excited unpleasant transverse superstructure vibration with the frequency of approximately 0.470 Hz. Hence, it seems possible that a pair of stays vibrating in phase may excite deck vibrations". Soon after this Bridge opened, a storm dumped heavy damp snow in the area, causing the six longest cable stay pairs of the main span to undergo large-amplitude vibrations, and the superstructure underwent considerable displacements in combined torsion-sway and bending modes. This necessitated rehabilitation measures for the Bridge including devices to suppress the large-amplitude vibrations of cables. The rehabilitation and monitoring of the Bridge are also presented here.

ABC 배전 접속 시스템에 대한 연구 (The Research into Connecting System for Aerial Bundled Cable in Distribution Line)

  • 이용순;최경선;주종민;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.495-498
    • /
    • 2001
  • The distribution line through which electricity is supplied from substation to customer generally varies by underground line and overhead line. In contrast that the underground line is shielded, the overhead lines do not have the shield layer. To overcome this weak point of the overhead lines, the aerial bundled cable(ABC) connection systems have been developed. The basic concept of the ABC connection system is the application of the underground cable system containing complete shield layer to the overhead cable system. The ABC system is the innovative technologies which enable the prevention of electric shocks, reduction of the maintenance charge and damage of the cable. This paper give a full detail of vertical connection system applied within a country.

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

케이블 접속재 부분방전 특성에 미치는 보이드의 영향 (Influence of Partial Discharge Properties due to Void in Cable Joint Parts)

  • 신종열;홍진웅
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

NbTi 초전도 케이블의 피로손상에 따른 RRR의 거동 (RRR Behavior due to Fatigue Damage in a NbTi Superconductor Cable)

  • 신형섭;배영준;하동우;오상수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.30-33
    • /
    • 1999
  • In this study, the fatigue test at room temperature and residual resistivity measurement test at 12K were carried out, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable, in order to investigate how the fatigue damage effects on critical properties. Through the fatigue test of a 9 strand Cu-Ni/NbTi/Cu composite cable, a conventional S-N curve was obtained even though there existed a possibility of fretting among strands. From the resistivity measurement of a NbTi strand after fatigue tests, it was found that with increase of the repeated number the RRR increased slightly, and the trend became significant with increase in maximum value of the applied stress amplitude.

  • PDF

Theoretical and experimental study on damage detection for beam string structure

  • He, Haoxiang;Yan, Weiming;Zhang, Ailin
    • Smart Structures and Systems
    • /
    • 제12권3_4호
    • /
    • pp.327-344
    • /
    • 2013
  • Beam string structure (BSS) is introduced as a new type of hybrid prestressed string structures. The composition and mechanics features of BSS are discussed. The main principles of wavelet packet transform (WPT), principal component analysis (PCA) and support vector machine (SVM) have been reviewed. WPT is applied to the structural response signals, and feature vectors are obtained by feature extraction and PCA. The feature vectors are used for training and classification as the inputs of the support vector machine. The method is used to a single one-way arched beam string structure for damage detection. The cable prestress loss and web members damage experiment for a beam string structure is carried through. Different prestressing forces are applied on the cable to simulate cable prestress loss, the prestressing forces are calculated by the frequencies which are solved by Fourier transform or wavelet transform under impulse excitation. Test results verify this method is accurate and convenient. The damage cases of web members on the beam are tested to validate the efficiency of the method presented in this study. Wavelet packet decomposition is applied to the structural response signals under ambient vibration, feature vectors are obtained by feature extraction method. The feature vectors are used for training and classification as the inputs of the support vector machine. The structural damage position and degree can be identified and classified, and the test result is highly accurate especially combined with principle component analysis.

PL법 환경하에서 열 충격에 따른 전력케이블의 재료분석 및 사고위험성 (The Accident Hazard and Material Analysis of Power Cable due to Thermal Stress under PL System)

  • 김영석;송길목;정진수;정종욱;김선구;김상현
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.82-87
    • /
    • 2008
  • It is impossible to database(DB) the patterns of power cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of power cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to cracking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). From the results, The 22.9kV calss A power cable was discolored on the surface and significantly reduced in the longitudinal direction. As the thermal weight properties of A power cable was definitely varied, we are able to guess the problem of manufacture. If the cable was defect by the manufacture, the victims would be able to claim for damage in the PL system.