• Title/Summary/Keyword: Cable Network

Search Result 370, Processing Time 0.027 seconds

The Effect of Discoloration on the Electrical Properties of Alumina Filled Epoxy (Alumina Filler가 충진된 에폭시 경화물(硬化物)의 변색(變色)이 전기적(電氣的) 특성(特性)에 미치는 영향(影響))

  • Hahn, K.M.;Kim, D.W.;Oh, M.W.;Kweon, H.S.;Kim, Y.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.59-62
    • /
    • 1993
  • This Paper studies on thermal oxidation of alumina filled epoxy network polymer used in Extra-High voltage application. The thermal oxidation of surface has investigated by yellow index variation and various electrical properties which are surface resistivity, tracking resistance and AC dielectric strength are estimated by yellow index.

  • PDF

FDTD Analsysis of Lightning-Induced Voltages on Shielded Telecommunication Cable with Multipoint Grounding

  • Ju, Jae-Cheol;Lee, Hyun-Young;Park, Dong-Chul;Chung, Nak-Sam
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.88-94
    • /
    • 2001
  • In this paper, the lightning-induced voltages on shielded twisted-pair wires with multipoint grounding on cable sheath are calculated by using finite-difference time domain (FDTD) method. The equivalent single-wire line that represents a bundle of twisted-pair wires is adopted for computational efficiency. A finitely conducting ground is also taken into account in both lightning electromagnetic field calculations and surge propagation along the shielded cable for a practical simulation. It is found that multipoint additional grounding on cable sheath provides more shielding effectiveness especially in the early time response of the lightning-induced voltages. From this study, the requirements for lighting surge protection devices in a telecommunication subscriber cab1e can be established.

  • PDF

Characteristics and Analysis of CATV Home Networks (CATV 홈 네트워크의 특성 분석)

  • Park, Sung-Wook;Park, Jong-Kwan;Ohm, Woo-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.286-291
    • /
    • 2013
  • Home CATV networks comprise coaxial cables and signal splitters which have less than ideal characteristics. Home network testing facilities use long lengths of coaxial cables, often undesirably coiling and bending the cable, stressing joints on connectors. Cable connectors, cable placement, bending and flexing can cause leakage of signals and can result in undesired signal paths in a system causing deteriorated performance. The purpose of this paper is to bring to light the issues of signal leakage and radiation from shielded media such as RG-59 and RG-6 coaxial cables, furthermore signal splitters have less than ideal characteristics.

FVT Signal Processing for Structural Identification of Cable-stayed Bridge (사장교의 구조식별을 위한 가진실험 데이터분석)

  • 이정휘;김정인;윤자걸
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.923-929
    • /
    • 2004
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neuralnetwork. 7he considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck. and vortical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used for the structural identification using arbitrarily added masses to the bridge.

Regulation of Violence: Violence Standards and Sanction (폭력물 규제: 심의규정과 제재조치 위반에 관한 분석)

  • Kim, Yoojung
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.164-175
    • /
    • 2014
  • The purpose of this study is to confirm violence regulation of television. Television programs that infringed the standards of violence and were sanctioned, were analyzed in terms of broadcasting violence standards and the level of sanction imposed, according to network and cable television. The results show that both network and cable television were mainly imposed on sanction of caution and recommendation. And violation of article 36 was most. But there were differences in violation of articles 36, 39, 51 between network and cable television.

Proposal Of Optimum Equalizer Hardware Architecture for Cable Modem and Analysis of Various LMS Algorithms (케이블모뎀용 등화기에 적용되는 다양한 LMS알고리즘에 관한 성능평가 및 최적의 등화기 하드웨어구조 제안)

  • Cho, Yeon-Gon;Yu, Hyeong-Seok;Kim, Byung-Wook;Cho, Jun-Dong;Kim, Jea-Woo;Lee, Jae-Kon;Park, Hyun-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2C
    • /
    • pp.150-159
    • /
    • 2002
  • This paper presents the convergence time, SER(Symbol Error Rate), MSE(Mean Square Error), hardware complexity and step-size(${\mu}$) about various LMS(Least Mean Square) algorithms in FS-DFE(Fractionally Spaced-Decision Feedback Equalize) for Cable Modem based on MCNS(Multimedia Cable Network System) DOCSIS(Data Over Cable Service Interface Specification) v1.0/v1.1 standards. We designed and simulated using ${SPW}^{TM}$ and synthesized using STD90 library through ${SYNOPSYS}^{TM}$. And also, we adopted the time-multiplexed multiplication and tap shared architecture in order to achieve the low hardware complexity. Simulation results show that DS-LMS algorithms[1][3] is the optimum solution about performace and hardware size. in high order QAM applications. Finally, we achieved area saving about 58% using DS-LMS algorithm compare with conventional equalizer architecture.

Tensile Strength on Connection Socket of Cables (케이블 연결 소켓의 인장강도)

  • Park, Kang-Geun;Lee, Jang-Bok;Ha, Chae-Won;Kim, Jae-Bong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.37-42
    • /
    • 2008
  • Cable member in structure is tension systems in which the load carrying members transmit loads to support system by tensile stress with no compression or flexure allowed. Cable system have been widely used large span structure roof, air-supported structure, prestressed membrane, cable network roof, suspension structures, guyed tower, ocean platforms, suspension bridges. Cable member can transmit loads by the edge connected system such as socket, swaging, mechanical splice sleave, clip, wedge, loop splice etc. This study will shown an experimental results on the strength of connection socket of cables. In the results of experiment, most of cable connection specimen occurred the failure at the connection socket part before the cable arrived at tensile failure load.

  • PDF

Design of UTP LAN Cable With Enhanced Alien Crosstalk Characteristic (이질 누화 특성이 개선된 UTP LAN 케이블의 설계)

  • Kim, June-Hyong;Lee, Seong-Jun;Oh, Sung-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1115-1121
    • /
    • 2012
  • In this paper, the design of UTP LAN cable with enhanced alien crosstalk characteristic is proposed. Proposed LAN cable is made with jacket of the irregularly corrugation type. If necessary, it is possible to use the special cross-filler. The alien crosstalk characteristic is enhanced by using proposed cable with inner jacket of the irregularly corrugation type in wide frequency band. The design of the cable was based on parameters of the standard EIA/TIA 568-B.2-10.

Method for Power control of Wired and Wireless linkage Sensor Network for Low-power Wireless network (저전력 무선 네트워크를 위한 유무선 연동 센서 네트워크의 전력 제어 방법)

  • Lee, Kyung-Sook;Kim, Hyun-Deok
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2012
  • In this paper, using a new low-power consumption method for ZigBee device, which consume low-power using an output power control algorithm through RSSI monitoring as interlocking wireless network using ZigBee which has advantages of a low-power consumption, a low-cost, a compatibility and a draft international standardization enacted by IEEE and ZigBee Alliance, with wired network using built coaxial cable to overcome the disadvantage of the existing wireless sensor network, is proposed. Effectiveness of the output power control algorithm through RSSI monitoring has been verified by experimentation for more optimized low-power consumption.

Refinement of damage identification capability of neural network techniques in application to a suspension bridge

  • Wang, J.Y.;Ni, Y.Q.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.77-93
    • /
    • 2015
  • The idea of using measured dynamic characteristics for damage detection is attractive because it allows for a global evaluation of the structural health and condition. However, vibration-based damage detection for complex structures such as long-span cable-supported bridges still remains a challenge. As a suspension or cable-stayed bridge involves in general thousands of structural components, the conventional damage detection methods based on model updating and/or parameter identification might result in ill-conditioning and non-uniqueness in the solution of inverse problems. Alternatively, methods that utilize, to the utmost extent, information from forward problems and avoid direct solution to inverse problems would be more suitable for vibration-based damage detection of long-span cable-supported bridges. The auto-associative neural network (ANN) technique and the probabilistic neural network (PNN) technique, that both eschew inverse problems, have been proposed for identifying and locating damage in suspension and cable-stayed bridges. Without the help of a structural model, ANNs with appropriate configuration can be trained using only the measured modal frequencies from healthy structure under varying environmental conditions, and a new set of modal frequency data acquired from an unknown state of the structure is then fed into the trained ANNs for damage presence identification. With the help of a structural model, PNNs can be configured using the relative changes of modal frequencies before and after damage by assuming damage at different locations, and then the measured modal frequencies from the structure can be presented to locate the damage. However, such formulated ANNs and PNNs may still be incompetent to identify damage occurring at the deck members of a cable-supported bridge because of very low modal sensitivity to the damage. The present study endeavors to enhance the damage identification capability of ANNs and PNNs when being applied for identification of damage incurred at deck members. Effort is first made to construct combined modal parameters which are synthesized from measured modal frequencies and modal shape components to train ANNs for damage alarming. With the purpose of improving identification accuracy, effort is then made to configure PNNs for damage localization by adapting the smoothing parameter in the Bayesian classifier to different values for different pattern classes. The performance of the ANNs with their input being modal frequencies and the combined modal parameters respectively and the PNNs with constant and adaptive smoothing parameters respectively is evaluated through simulation studies of identifying damage inflicted on different deck members of the double-deck suspension Tsing Ma Bridge.