• Title/Summary/Keyword: Cable Impedance

Search Result 132, Processing Time 0.03 seconds

Analysis of Sequence Impedances of 345kV Cable Transmission Systems (실계통 345kV 지중송전선 대칭좌표 임피던스의 해석)

  • Choi, Jong-Kee;Ahn, Yong-Ho;Yoon, Yong-Beum;Oh, Sei-Ill;Kwa, Yang-Ho;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables (웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.

Feasibility study on the inductive fault current limiting cable

  • Lee, Sang Yoon;Choi, Jongho;Kim, Dong Min;Sim, Kideok;Cho, Jeonwook;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.24-28
    • /
    • 2013
  • Fault current limiting (FCL) cable is a kind of superconducting cable which has a function of limiting the fault current at the fault of power grid. The superconducting cable detours the fault current through its stabilizer to keep the temperature as low as possible. On the other hands, the FCL cable permits the temperature rise within some acceptable limit and the fault current is limited by the consequent increase of the resistance of superconducting cable. This kind of FCL cable is called 'resistive FCL cable' because it uses resistive impedance to limit the fault current. In this paper, we suggest a novel concept of FCL cable, which is named as 'inductive FCL cable'. The inductive FCL cable is similar as the magnetic shielding fault current limiter in its operating mechanism. The magnetic field of superconducting cable is almost perfectly shielded by the induced current at the shielding layer during its normal operation. However, at the fault condition, quench occurs at the shielding layer by the induced current higher than its critical current and the magnetic field is spread out of the shielding layer. It will induce additional inductive impedance to the superconducting cable and the inductive impedance can be increased more by installing some material with high magnetic susceptibility around the superconducting cable. We examined the feasibility of inductive FCL cable with simple elemental experiments. The current limiting performance of inductive FCL cable was estimated considering an arbitrary power grid and its fault condition.

Shielding Effect Analysis of Communication Cables Using EN50289 for Transfer Impedance Measurement of Coaxial Cable (EN50289 동축케이블 전달 임피던스 측정 방법을 이용한 통신 케이블의 차폐 효과 분석)

  • Lee, Keunbong;Zhang, Nan;Jeon, Jiwoon;Song, Seungje;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1156-1163
    • /
    • 2014
  • In this work by measuring transfer impedance of communication cables using EN50289 its Shielding effect is analyzed. transfer impedance measurement triaxial method using EN50289 is defined in CENELEC, it is unlike triaxial method prescribed in IEC Standard 96-1, can be measured regardless of diameter of coaxial cable and outer conductor. in this paper, transfer impedance measurement device of coaxial cable is designed and made according to EN50289 standard, The analysis determines the reliable working frequency range of coaxial cable and examined the impact of different shielding methods on coaxial cable. The transfer impedance measurements show considerable variations in results with various shielding methods. also the measurement procedure is verified through comparison of calculated and measured transfer impedance of RG-58 cable.

Line Impedance Analysis of Underground Cable in Power Plant (발전소에 포설된 케이블 선로 임피던스 분석)

  • Ha, C.W.;Han, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.612-613
    • /
    • 2007
  • The line impedance is important data that are applied in all analysis fields of electric power system such as power flow, fault current, stability and relay calculation etc. Usually, the impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, the impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistances. Therefore, if there is a fault in cable system, these terms will severely be caused many errors for calculating impedance. In this paper, the line impedance is measured in a power system of underground cables, and is analyzed by a generalized circuit analysis program, EMTP(Electromagnetic Transient Program), for comparison with the measured value. These analysis results are considered to become foundation of impedance calculation for underground cables.

  • PDF

Wideband Impedance Transformer Using a Coaxial Cable (동축선을 이용한 광대역 임피던스 트랜스포머)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.789-794
    • /
    • 2011
  • A coaxial-cable impedance transformer used in wideband frequency range is generally restricted to the fixed impedance transformation ratio as n2:1 or 1:n2(n: the number of coaxial cables). In this paper, we propose a new coaxial-cable impedance transformer to have an arbitrary impedance transformation ratio. We have fabricated three impedance transformers($50-{\Omega}$ to $25-{\Omega}$, $50-{\Omega}$ to $20-{\Omega}$ and $50-{\Omega}$ to $9-{\Omega}$) to confirm the operation characteristic of the suggested impedance transformer. The reflection characteristics (S11) of the fabricated $50-{\Omega}$ to $25-{\Omega}$ and $50-{\Omega}$ to $20-{\Omega}$ impedance transformer were less than -15dB over about 3-octaves frequency range and the reflection characteristic (S11) of the fabricated $50-{\Omega}$ to $9-{\Omega}$ impedance transformer was less than -15dB over about 1-octave frequency range, respectively.

Wideband Power Divider Using a Coaxial Cable (동축선을 이용한 광대역 전력 분배기)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.661-668
    • /
    • 2012
  • A coaxial-cable impedance transformer that can be used in high power and wideband frequency range is an arbitrary impedance transformation ratio by an additional coaxial cable. The coaxial-cable impedance transformer to be 50-${\Omega}$ to 25-${\Omega}$ impedance transformation ratio is easily operated an wideband power divider by connecting two 50-${\Omega}$ lines at 25-${\Omega}$ impedance point. This wideband power divider has a poor output matching characteristic and a poor isolation characteristic between two output ports. In this paper, it proposes a coaxial-cable power divider to be a good output matching and isolation characteristics as it uses the singly terminated filter design theory. The odd-mode operation characteristic of the suggested power divider to use singly terminated low pass filter coefficient due to matching order and ripple value is examined by ADS program. And, it fabricates and measures the operation characteristic of 2-way power divider with 2nd-order and 4th-order matching circuit.

Impedance Calculation of an Underground Transmission Cable System Installed with a Sheath Current Reduction Device

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Wang, Xin Heng;Song, Yong Hua
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.236-242
    • /
    • 2004
  • Previous research results indicated that the designed current reduction device could effectively reduce the sheath circulating current and that its RDP protection device could shield it against both fault and lightning strokes. In this paper, cable impedance is analyzed using wavelet analysis and distance relay algorithm following the installation of these devices so that the operation of distance relay can be estimated. The test results confirm that in these devices, the fault inception angle and SVL bonding types have no impact on the change of cable impedance. In other words, the conventional distance relay can be used without a new relay setting. Thus we can finally assert that the designed current reduction device and its protection device are effective and can be safely installed on the cable transmission system without disturbance.

Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable (초전도 케이블의 퀜치 특성에 대한 계통안전성 제어방식)

  • Lee, Geun-Joon;Hwang, Si-Dol;Lee, Jeong-Phil;Kim, Chang-Hyun;Park, Hye-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.375-380
    • /
    • 2004
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, and HTS cable could be one of the countermeasure to solve the transfer limit as its higher current capacity and lower impedance[1]. However, the quench characteristic of HTS cable makes HTS cable to loss its superconductivity, and therefore change the impedance of the line and power system operating condition dramatically. This pheonominum threats not only HTS cable safety but also power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method by FCL(Fault Current Limiter) was suggested.

  • PDF