• 제목/요약/키워드: Cable Impedance

검색결과 132건 처리시간 0.02초

EMTP를 이용한 인버터 구동 고압 유도전동기의 스위칭 써지 특성 분석 (The Analysis on the Switching Surge of High-voltage Induction Motor fed by Inverter Using EMTP)

  • 송승엽;김재철;신중은;권영목;황돈하
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.58-62
    • /
    • 2004
  • The PWM inverter drive my cause motor terminals voltage surge and oscillation(ringing), which impose severe electric stresses on inter-turn insulation of motor windings. This paper describes the technique used to simulate the problems associated with the use of PWM ASD's(Adjustable Speed Drive) to drive induction motor. The characteristic of switching surge was analyzed by EMTP(Electromagnetic transient program) model. The effects of switching surge by surge impedance, rise-time and cable lengths are also discussed.

  • PDF

Inter-Phase Transformers를 이용한 고온초전도 케이블의 층간 전류 등분배 방안 (A method for uniform current distribution of HTS cable using Inter-Phase Transformers)

  • 최용선;임성우;심종욱;황시돌;박인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.973-975
    • /
    • 2003
  • Uniform current distribution among conductor layers in HTS cables using IPTS (inter-phase transformers) was proposed. Conventional methods for current distribution, in which resistors are inserted to conductor layers, causes additional loss. In contrast, IPTS, which use magnetic coupling, make it possible that the current in parallel circuits is distributed uniformly with any load, and minimize the loss. In this study, IPTS were designed and fabricated for examination of uniform current distribution in the conductor layers of HTS cables. The ITP was designed through calculation of its impedance that can cancel the inductance of the conduction layers.

  • PDF

하이브리드 반도체 변압기의 1차측 정보를 이용한 2차측 간접 정전압 제어 기법 (Secondary Indirect Constant Voltage Control Technique for Hybrid Solid State Transformer using Primary Side Information)

  • 이태영;윤춘기;조영훈
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.420-423
    • /
    • 2020
  • This study proposes an indirect constant voltage control algorithm for hybrid solid-state transformers (HSSTs) by using primary side information. Considering the structure of HSSTs, measuring voltage and current information on the primary side of a transformer is necessary to control the converter and inverter of the power converter. The secondary side output voltage is measured to apply the conventional secondary side constant voltage control algorithm, and thus, the digital control board requires the same rated insulation voltage as that of the transformer. To solve this problem, the secondary voltage of the transformer obtained from the tap voltage is used. Moreover, output voltage decreases as load increases because the proposed indirect constant voltage control scheme does not consider the cable impedance between the secondary output terminal and the load. This study also proposes a technique for compensating the secondary output voltage by using the primary current of the transformer and the resistance value of the cable. An experiment is conducted using a scale-down HSST prototype consisting of a 660 V/220 V tap transformer. The problem of the proposed indirect constant voltage control strategy and the improvement effect due to the application of the compensation method are compared using the derived experimental results.

승강기 Car용 고속응성 배터리 충전시스템에 적합한 제어알고리즘 (A Control Algorithm Suitable for High-speed Response Battery Charging System for Elevator Car)

  • 이정환;황보찬;박성준;박성미;고재하
    • 한국산업융합학회 논문집
    • /
    • 제25권6_2호
    • /
    • pp.1071-1081
    • /
    • 2022
  • As the demand for high-rise buildings increases, the demand for high-speed elevators is also increasing. In order to make a high-speed elevator, a method is needed to reduce the weight of the elevator's components, which is a constraint on the increase in speed. As a measure to reduce the weight, it is possible to remove the traveling cable for power and signal supply. Since the weight of the traveling cable varies depending on the position of the carriage, it is difficult to compensate the weight using the counter weight. The power supply is a structure in which a brush-rail type power input terminal is installed in the elevator hoistway to receive power in a contact-type manner while the carriage is moving. If a small-capacity ESS is installed in a passenger car, power can be supplied uninterruptedly inside the passenger car. A small-capacity ESS charging system to be applied to such an elevator system is required to perform several functions. First, the passenger Car must be able to charge as much as possible even during high-speed operation. A control algorithm with high responsiveness is required because charging starts and ends repeatedly by the partially installed input power stage. In addition, if the input-side line impedance is large due to the structure of the system and the response characteristic is increased, the stability of the system may be lowered. Accordingly, in this paper, we propose a control algorithm that has a stable steady-state output while having a fast response in a transient state. To verify the proposed control algorithm, simulation was conducted using PSIM, and the performance of the controller was verified by manufacturing a prototype buck conveter charger.

뇌보호시스템에서 인하도선의 효과적인 설치기법 (Effective Installation Methods of Down Conductors in Lightning Protection Systems)

  • 이복희;엄주홍;이승칠;강성만
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.8-14
    • /
    • 2002
  • 현대의 뇌보호시스템은 낙뢰로 인한 감전이나 건축물, 전기·전자기기의 파손과 같은 위험성을 제거하는 것이 요구되지만 종래의 뇌보호설비는 단지 인명의 피해나 건축물을 보호하는 것이 주된 역할이었다. 오늘날 컴퓨터, 정보통신설비 등을 효과적으로 보호할 수 있는 뇌보호설비가 필수적 요건으로 대두되었다. 본 논문에서는 뇌과전압으로부터 컴퓨터와 전자장비를 보호할 수 있는 기술을 개발할 목적으로 인하도선의 종류와 설치기법에 따라서 인하도선에 유도되는 전위상승 억제에 대한 연구를 수행하였다. 그 결과 인하도선의 전위상승에 의한 측면방전과 위험성을 줄이기 위해서는 인하도선으로 낮은 특성임피던스를 가지는 동축케이블이 적당하며, 인하도선과 금속관을 상단과 하단에서 본딩하는 방법이 효과가 높게 나타났다.

Design and characteristic investigations of superconducting wireless power transfer for electric vehicle charging system via resonance coupling method

  • Chung, Y.D.;Yim, Seong Woo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권3호
    • /
    • pp.21-25
    • /
    • 2014
  • As wireless power transfer (WPT) technology using strongly coupled electromagnetic resonators is a recently explored technique to realize the large power delivery and storage without any cable or wire, this technique is required for diffusion of electric vehicles (EVs) since it makes possible a convenient charging system. Typically, since the normal conducting coils are used as a transmitting coil in the CPT system, there is limited to deliver the large power promptly in the contactless EV charging system. From this reason, we proposed the combination CPT technology with HTS transmitting antenna, it is called as, superconducting contactless power transfer for EV (SUWPT4EV) system. As the HTS coil has an enough current density, it can deliver a mass amount of electric energy in spite of a small scale antenna. The SUCPT4EV system has been expected as a noble option to improve the transfer efficiency of large electric power. Such a system consists of two resonator coils; HTS transmitting antenna (Tx) coil and normal conducting receiver (Rx) coil. Especially, the impedance matching for each resonator is a sensitive and plays an important role to improve transfer efficiency as well as delivery distance. In this study, we examined the improvement of transmission efficiency and properties for HTS and copper antennas, respectively, within 45 cm distance. Thus, we obtained improved transfer efficiency with HTS antenna over 15% compared with copper antenna. In addition, we achieved effective impedance matching conditions between HTS antenna and copper receiver at radio frequency (RF) power of 370 kHz.

Analysis on Monopole Antenna for Moisture Determination in Oil Palm Fruit Using Finite Difference Method

  • Cheng, E.M.;Abbas, Z.;Rahim @ Samsuddin, H.A.;Lee, K.Y.;You, K.Y.;Hassan, J.;Zainuddin, H.;Khor, S.F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1754-1762
    • /
    • 2016
  • Finite difference analysis were applied to study the principle operation of monopole antenna for moisture determination in oil palm fruit at 2 GHz. The electromagnetic field interact with oil palm fruit on the interface between the antenna and oil palm fruit and cause a reflection. The reflection measurement is based on mismatch impedance or dielectric properties between two media. Reflection coefficient is used to quantify the level of reflection. The monopole antenna was made of RG405/U semi-rigid coaxial cable with an inner and outer diameter of 0.45 mm and 1.50 mm, respectively with 2.23 mm length of protruding conductor over 5.66 cm length of monopole antenna. This monopole antenna for moisture detection was compared with induced EMF method in terms of reflection coefficient at 2 GHz. The results show that the complex reflection coefficient measured using monopole antenna provides significant results to predict moisture content in oil palm fruit.

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구 (Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System)

  • 김이훈;박규현;원충연;김영석;최세완
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.546-555
    • /
    • 2001
  • 본 논문에서는 PWM 인버터-유도전동기 구동시스템의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구를 수행하였다. 전도노이즈는 고전압 입력, 고용량 구동시스템 그리고 긴 전동기 터미널 등의경우에서 크게 문제가 된다. 고압력을 갖는 시스템에서는 높은 압력에 비례한 직류 링크 전압을 갖고 이에 따라 스위칭 dv/dt가 순간 최대 CM 접지전류를 발생시킨다. 그러므로 이에 대한 대책이 필요하다. 따라서 최근 산업 현장에서 많이 사용되고 있는 PWM 인버터를 설계 제작하여 유도전동기를 구동하고 이에 따라 발생되는 전도노이즈 성분을 감쇠 시킬 수 있는 출력필터를 설계하였고 제작 및 실험을 통하여 그 타당성을 입증하였다.

  • PDF