• 제목/요약/키워드: Cable Diagnosis

검색결과 153건 처리시간 0.039초

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Characteristic Analysis on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;정우성;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.1035-1042
    • /
    • 1998
  • After the 1990's, a computer-aided partial discharge(PD) measurement system was referred in part of aging diagnosis using digital signal processing as the new technology has been studied. The PD patterns and relevant information for pattern recognition are discussed in PD research area, because discharge quantity(q), the number of discharge pulse(n) and the applied boltage phase($\varphi$) was combined with the system information of the aging state. This paper investigates the discharge phase and quantity, as well as the number of discharge(n) with regard to discharge signals generated in power cable. therefore, according to characteristic analysis on the distribution of $\varphi$, q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

미약한 결함에 의한 반사 계수 변화를 이용한 제어 및 전력 케이블의 상태 진단 (Diagnosis of Power and Control Cables Using Change of Reflection Coefficients Due to Weak Fault)

  • 용환구;;채장범;김병성
    • 한국전자파학회논문지
    • /
    • 제25권12호
    • /
    • pp.1269-1274
    • /
    • 2014
  • 고주파에서 손실이 큰 전력 및 제어용 케이블은 주파수 대역폭이 좁기 때문에 기존의 반사 진단법을 이용해 미약한 손상을 진단하기 어렵다. 이는 미약 손상 지점에 의한 반사파가 초단 및 종단 반사파에 가려져 고장점 진단이 어렵기 때문이다. 본 논문에서는 전송선 이론에 기반하여 미약한 손상에 의한 반사파는 종단 반사파와 선형 중첩 파형으로 근사할 수 있음을 증명하고, 이 모델을 이용하여 손상 전후의 반사계수 차를 통해 미약 손상점을 진단할 수 있음을 실험을 통해 검증하였다.

발전설비의 성능진단 적용 무선계측 기술 (Wireless Measurement Technology for Power Plant Performance Diagnosis)

  • 김의환;이응곤;홍은기
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.9-16
    • /
    • 2017
  • The performance test is conducted for the purpose of determining the accurate thermal performance of the power generation facility or deriving the factors of thermal efficiency degradation. Compared to the acquisition method of power plant thermal performance test data by compensating cable or transmission cable, performance test using wireless instrument can acquire digital data in order to shorten the period due to installation and demolition of instrument and enhance safety of workers and relatively accurate data can be acquired thereby improving work efficiency. Wireless instruments have already been introduced to the market a long time ago, and some of them are used in industry such as petrochemical industry. However, there is no example which has been conducted for performance test of power generation facilities. In order to apply power generation facilities, a reliable system capable of acquiring performance data smoothly without affecting the control system is required. The wireless measurement system can eliminate the measurement defects and errors such as the damage due to the movement of the connecting cable, the extension due to the extension of the shield wire, the contact failure at the contact point between the measuring sensor and the connecting wire, This method has the advantage of collecting relatively accurate performance test data.

안테나를 이용한 전력용 케이블의 절연진단 연구 (Insulation Diagnosis Study of Power XLPE Cable by Used Atenna)

  • 이현철;최은혁;박광서;윤대희;지승욱;이상훈;김충년;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1805-1807
    • /
    • 2004
  • This simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. Asone of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMl, EMC. From results of this study, It was confirmed that discharge progress were possible to be estimated by the proposed method.

  • PDF

전력 케이블의 열화진단 (DIAGNOSIS OF DETERIORATION FOR HIGH VOLTAGE CABLE)

  • 최창수;김영;김장원;김영남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1353-1355
    • /
    • 1995
  • While the modern society has been highly diversified and civilized, the demand for the safty of a power transmission has been greatly increased. For the underground cable, the performance of the electrical equipments is being improved by developing a new technology, and the reliability of the power supply is being up graded by impressing the diagnostic and monitoring technology of the system. In this paper the aging procedure of O.F and XLPE cables are described, including the diagnostic and monitoring equipments and the future subject.

  • PDF

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술 (Partial Discharge Diagnosis technology of EHV Underline Transmission XLPE cable applied FSA)

  • 신동훈;이용성;양종석;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.153-154
    • /
    • 2006
  • We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.

  • PDF

전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작 (Design and Fabrication of a PD Detector for Power Cable Diagnosis)

  • 송재용;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

A Study on Partial Discharge Diagnostic System for Power Cable using RLCR

  • Park, Keeyoung;Choi, Hyungkee;Lee, Chulhee;Hong, Soomi
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.43-47
    • /
    • 2016
  • This system is a diagnosis system that checks whether it causes a partial discharge of a power cable or not. It is to classify normal from abnormal-normal, PD (Partial Discharge) sound through analysis of RLCR (Relative Level Crossing Rate) and spectrogram energy algorithm. Partial discharge diagnostic system has a function that stores PD sound and analyzes the data. The wave shape of PD sound is similar to noise and is systematically generated by partial discharge. Therefore, in this paper, we could discreminate between normal and abnormal case using relative level crossing rate (RLCR) and spectrogram of frequency energy rate.

22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구 (A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable)

  • 김용준;오용철;이건영
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.