• 제목/요약/키워드: Cable Crosstalk

Search Result 12, Processing Time 0.023 seconds

A Design of Microwave Measurement Board for Multi-channel Coaxial Cable Assembly (다중 채널 동축 케이블의 초고주파 측정용 보드 설계)

  • Moon, Soo-Deok;Kim, Jin-Kyu;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.169-175
    • /
    • 2007
  • In High-Speed DSP systems, crosstalk between transmission lines of multi-channel can degrade the performance of equipment operations. This paper presents a microwave board to measure multi-channel coaxial cable assembly. The designed board has good performances from DC to 3 GHz, which have improved characteristic impedance, reduced crosstalk by using via fence, and low transmission loss. Using the designed board, we can measure characteristics of DUT(Device Under Test) such as return loss, insertion loss, crosstalk phase delay, and characteristic impedance. The measured results are used to improve performances of a produced coaxial cable assembly.

  • PDF

A Cable Crosstalk Simulation method using Microwave Studio & T-matrix Cascading and Crosstalk Analysis of Twisted Wire Pairs(TWP) including Straight Sections (Microwave Studio와 전달행렬 캐스케이딩을 이용한 케이블 누화 시뮬레이션 방법과 직선구간을 포함하는 Twisted Wire Pairs(TWP) 누화 분석)

  • Min, Tae Hong
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.1
    • /
    • pp.47-54
    • /
    • 2017
  • This research explains a simulation method of cable crosstalk using Microwave Studio(MWS), Matlab and analyzes the crosstalk of Twisted Wire Pairs(TWP) applied to the aerospace or the military. TWP have a periodic configuration of long twisted wires along a axis. It is impossible to conduct the simulation of TWP due to the increased meshs according to the long length configuration. Transmission matrix(T-matrix) cascading method which is suitable to analyze the periodic configuration has been adopted to get the crosstalk of total cable so that the total simulation time has been decreased. In this paper, the crosstalk analysis of TWP including the connector modeled to straight sections has been performed.

Design of UTP LAN Cable With Enhanced Alien Crosstalk Characteristic (이질 누화 특성이 개선된 UTP LAN 케이블의 설계)

  • Kim, June-Hyong;Lee, Seong-Jun;Oh, Sung-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1115-1121
    • /
    • 2012
  • In this paper, the design of UTP LAN cable with enhanced alien crosstalk characteristic is proposed. Proposed LAN cable is made with jacket of the irregularly corrugation type. If necessary, it is possible to use the special cross-filler. The alien crosstalk characteristic is enhanced by using proposed cable with inner jacket of the irregularly corrugation type in wide frequency band. The design of the cable was based on parameters of the standard EIA/TIA 568-B.2-10.

Crosstalk Compatibility between Different Transmission Modes Operating in a Same Cable Sheath (동일 Cable 뭉치에서 동작하는 이종 디지탈 전송시스템 간의 누화측면에서의 호환성 고찰)

  • 이효영;김재근;박권철;박정기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.13 no.1
    • /
    • pp.85-93
    • /
    • 1988
  • Installation of the digital carrier system is increased rapidly in the telecommunication network, and most of systems are operating over a twisted pair conductor. Many systems are accommodated in multipair cable for their economical installation, therefore we must consider tha crosstalk interference between digital systesm. This paper considers the calculation method which determine crosstali interference between signals in multipair. And the transmission margin at a certain error rate is analyzed considering crosstalk power. Finally, this paper estimates the crosstalk noise susceptibility of 2.048Mbps relative to 1.544Mbps PCM system and 1.544Mbps relative to 2.048Mbps PCM system, and then considers the methos which both systems can operate together in a same cable.

  • PDF

A Low-Crosstalk Design of 1.25 Gbps Optical Triplexer Module for FTTH Systems

  • Kim, Sung-Il;Park, Sun-Tak;Moon, Jong-Tae;Lee, Hai-Young
    • ETRI Journal
    • /
    • v.28 no.1
    • /
    • pp.9-16
    • /
    • 2006
  • In this paper, we analyzed and measured the electrical crosstalk characteristics of a 1.25 Gbps triplexer module for Ethernet passive optical networks to realize fiber-tothe-home services. Electrical crosstalk characteristic of the 1.25 Gbps optical triplexer module on a resistive silicon substrate should be more serious than on a dielectric substrate. Consequently, using the finite element method, we analyze the electrical crosstalk phenomena and propose a silicon substrate structure with a dummy ground line that is the simplest low-crosstalk layout configuration in the 1.25 Gbps optical triplexer module. The triplexer module consists of a laser diode as a transmitter, a digital photodetector as a digital data receiver, and an analog photodetector as a cable television signal receiver. According to IEEE 802.3ah and ITU-T G.983.3, the digital receiver and analog receiver sensitivities have to meet -24 dBm at $BER=10^{-12}$ and -7.7 dBm at 44 dB SNR. The electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysis and measurement results, the proposed silicon substrate structure that contains the dummy line with $100\;{\mu}m$ space from the signal lines and 4 mm separations among the devices satisfies the electrical crosstalk level compared to a simple structure. This proposed structure can be easily implemented with design convenience and greatly reduce the silicon substrate size by about 50 %.

  • PDF

Near-end Cross-talk Analysis of Unshielded Twisted Pair Cable using the Transmission Line Model (전송선로 모델을 이용한 UTP 케이블의 NEXT 해석)

  • Lee, Won-Hui;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.2
    • /
    • pp.59-63
    • /
    • 2009
  • The UTP cable has been widely used, recently it is being developed for use in the UHF frequency band. One important characteristic of the UTP cable is NEXT. This research is to develop a pitch selection technique for an UTP cable which leads to a satisfactory NEXT. The transmission line model involving mutual inductances and capacitances between line pairs is used, and the simulation was carried out for frequencies from 1 MHz to 600 MHz. With respect to the worst margin of the NEXT for a Cat. 6 cable the simulation and measurement results show a good agreement.

  • PDF

Study on the Removal of the Cable Braid Inside the Missile (유도탄 탄내케이블 브레이드 제거에 따른 고찰)

  • Eun, Hee-hyun;Kim, Ji-min;Lee, Min-hyoung;Jung, Jae-won
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • The North Korea nuclear issue is now posing a serious security threat to the Korea and Northeast Asia. Accordingly, the South Korean military is pushing for the introduction of long-range air-to-surface flights and the development of domestic nuclear facilities that can precisely hit North Korea headquarters building and nuclear facility even hundreds of kilometers above the border. In this paper, we removed the cable braid for securing the weight of the missile among several design elements for long-range air-to-surface missile development and estimated and analyzed the resulting performance. The possibility of braid removal was analyzed in terms of crosstalk inside the cable and CS114, RE101 of MIL-STD-461F.

Improved Method of Characteristics for Two way Subscriber Transmission Systems

  • Phetsomphou, Douangsamone;Tsuchiya, Naosuke;Tanaka, Kimio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1355-1359
    • /
    • 2004
  • The two way subscriber transmission systems have tendency to spread its carrier frequency bandwidth or information bit rate and average bit error rate according to popularization of high speed information through the digital communication system, transmission medium and the Internet. This fact is an important incentive to realize new systems. These two way subscriber transmission systems usually use same cable or same carrier frequency bandwidth for up stream channel and down stream channel. In the systems, the disturbances of noise, crosstalk or fading affect the characteristics. Specifically, these disturbances cause the decrease of information bit rate and degradation of transmission quality. This paper proposes the improved method of their degradations using the particular feature of two way subscriber transmission systems and it makes clear proposed method is effective by theoretically and some numerical examples.

  • PDF

Error Performance in DSL System for ISDN Basic Rate Access (ISDN 기본접속을 위한 DSL 시스템의 성능 평가)

  • 김득환;곽경섭;김진태;최병하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.29-39
    • /
    • 1993
  • For an economical or timely reason, the types of subscriber loops for ISDN basic rate access service will, at least initially, be that of the pre-existing telephone network, that is, 2-wire twisted-pair metallic cable. Therefore, it is important to assess the high-speed digital transmission capability of the 2-wire subscriber loops. In this paper, the impairments such as intersymbol interference, crosstalk, and impulse niose are modeled. And then, symbol error probabilities in terms of SNR in DSL system using ECH and 2B1Q line code are analytically derived and numerically calculated. Also, the relationship between the quality of service required in ISDN subscriber section and the loop parameters is investigated.

  • PDF

Analysis of Data Rate for Multimedia Network VDSL System (멀티미디어 통신망 VDSL 시스템의 전송속도 분석)

  • Park, In-Jeong;Yang, Geun-Mo;O, Seung-Rok
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.1
    • /
    • pp.75-81
    • /
    • 2002
  • In this paper, data rate of VDSL system was analyzed in noise and crosstalk environment. For this paper, Matlab tool was used to analyze the performance of VDSL system. Various "VDSL Test Loop" are used which is suggested by ANSI DSL Standard group T1E1.4. Many parameters, "Noise Model A", "Noise Model F", duplex method VDSL-998 which is suggested FDD plan by ANSI was used. The most of conditions for simulation are followed to the ANSI Standard "Spectrum management" Lots of data have been obtained according to the different conditions of the test loops. The result shows that the data rate of VDSL system is decreased due to the other DSL signals in the same cable bundle. And also there was more reduced data rate in case of Noise Model F than that of Noise Model A.