• 제목/요약/키워드: Cable Connection Part

검색결과 16건 처리시간 0.02초

154kV 케이블 콘넥터의 설계와 특성 평가 연구 (Performance and Design of Cable Termination for 154kV Class)

  • 조한구;김광용;이철호;이용순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

배전용 특고압 케이블 접속재의 다변수 측정 분석 연구 (Study on Multi Parameter Measurement and Analysis of Distribution High Voltage Cable Connection Part)

  • 송기홍;배영철;김이곤
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-60
    • /
    • 2021
  • 고전압 CV 케이블은 편의성과 도시적 미관으로 인해 지하에 널리 설치되고 있습니다. 그러나 케이블 사고는 조립불량과 자연 열화로 인해 자주 발생하고 있다. 본 논문에서는 고전압 케이블 접속부의 최적 진단을 위한 다변수 측정 방법을 제안하고 그 기술적 유용성을 검증한다. 다변수 측정은 부분방전과 함께 진동과 열화상을 동시에 사용하여 케이블 연결 부품의 성능 저하를 진단하기 위한 기술이다. 다변수 측정의 유용성을 확인하기 위해 차폐 실험실에서 가속열화 실험을 수행하였고, 실험은 케이블 접속부의 열화를 12가지 유형으로 정의하여 각 열화 샘플을 제작하였다. 실험 결과, 진동신호 방법은 열화 진행과의 상관관계가 있는 결함 종류를 확인할 수 있었다. 열화상 검사의 경우 일부 결함의 진행과 관련하여 일관성이 발견되었다. 본 논문에서 제안된 방법은 현장에서 유용할 것으로 판단된다.

케이블 연결 소켓의 인장강도 (Tensile Strength on Connection Socket of Cables)

  • 박강근;이장복;하채원;김재봉
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.37-42
    • /
    • 2008
  • 구조물에서 케이블 부재는 압축이나 휨이 없이 인장력에 의해서 하중을 전달하는 시스템이다. 케이블 시스템은 대공간 구조의 지붕, 공기 지지구조, 프리스트레스 막구조, 케이블 네트워크 구조, 현수구조, 가이드 타워, 해양 프래트폼, 현수교 등의 구조물에 널리 사용되어 왔다. 케이블 부재는 부재 단부에 소켓, 스웨이징, 스프라이스 슬리브, 클립, 웨지, 루프 스프라이스 등에 의해서 하중을 전달 할 수 있다. 본 연구에서는 케이블 연결 소켓의 인장강도에 대한 실험을 수행하고자 한다. 실험결과에서 대부분의 시험체가 케이블이 파단하중에 도달하기 전에 소켓의 연결부에서 파단이 일어났다.

  • PDF

용접 및 볼트 연결부 균열을 고려한 사장교 케이블 정착부의 동특성 해석 (Dynamic Characteristics of Cable-Stayed Anchorage considering Cracks at Bolt and Welding Connection)

  • 김철영;김성보;정우태
    • 한국강구조학회 논문집
    • /
    • 제11권4호통권41호
    • /
    • pp.351-362
    • /
    • 1999
  • 용접 및 볼트 연결부 균열이 사장교 케이블 정착부의 동특성에 미치는 영향을 파악하여, 국부적으로 취약한 케이블 정착부의 손상을 현장에서 쉽게 탐지할 수 있는 가능성을 제시하였다. 해석대상 구조물로서 현재 서해안고속도로의 일부로 시공되고 있는 서해대교 케이블 정착부를 선택하였다. 케이블과 정착부의 연결판을 케이블요소 및 쉘요소로 함께 모델링하여 자유진동해석을 수행하였다. 해석결과 케이블 정착단에서 용접부 균열이 발생한 경우, 연결판의 고유진동수가 균열이 발생하지 않은 경우에 비하여 최대 16%정도 작아짐을 확인하였다. 따라서, 연결판의 고유진동수를 측정하여 케이블 정착부의 손상을 충분히 파악할 수 있다고 판단된다.

  • PDF

2주탑 콘크리트 사장교의 경계조건별 지진 취약도 분석 (Seismic Fragility Analysis by Boundary Conditions of a Two-pylon Concrete Cable-stayed Bridge)

  • 신연우;홍기남;연영모;지상원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.77-85
    • /
    • 2020
  • 본 연구에서는 2주탑 콘크리트 사장교를 대상으로 경계조건에 따른 지진 취약도 곡선을 작성하고, 경계조건이 교량의 지진 취약도에 미치는 영향을 평가하고자 한다. 대상교량에 대한 해석모델이 Midas Civil을 사용하여 구축되었고 Fiber요소와 콘크리트, 철근의 재료모델을 적용하여 비선형 시간이력해석을 수행하였다. 주탑과 보강형 사이의 경계조건을 강결, 비구속, 포트받침, 면진받침의 총 4가지로 구분하여 각각의 경계조건에 대해 지진 취약도 곡선을 작성하였다. 주탑의 소성힌지구간과 연결부, 케이블을 취약부재로 선정하고 이 부재들에 대해 지진 취약도 곡선을 작성하였다. 분석결과 주탑의 소성힌지구간과 연결부에서는 면진받침모델이 가장 낮은 손상확률을 나타내고, 케이블의 지진 취약도는 경계조건에 의한 영향이 다른 부재에 비해 크지 않은 것을 알 수 있다.

초고성능 콘크리트 하이브리드 사장교 바닥판 접합부 철근의 부착 성능에 대한 해석 (Analysis on Bond Characteristics of Reinforcements for UHPC Hybrid Cable-Stayed Bridge Deck Joints)

  • 선우윤호;박성균;곽임종;윤영수
    • 대한토목학회논문집
    • /
    • 제31권3A호
    • /
    • pp.207-214
    • /
    • 2011
  • 높은 강도와 우수한 연성을 가지는 초고성능 콘크리트(Ultra High Performance Concrete, UHPC)는 교량 부재의 두께 및 자중을 감소시키는데 적합하여, 교량의 장대화, 장경간화에 유리한 재료로 각광 받고 있다. 그러나 초고성능 콘크리트는 타설 과정이 복잡하고 어렵기 때문에 현장 타설을 통한 적용이 어려운 재료이다. 따라서 이에 대한 대안으로 프리캐스트 공법을 활용하는 방안이 중점적으로 연구되고 있다. 본 연구에서는 이와 같은 연구의 일환으로 초고성능 콘크리트의 재료 특성을 고려하여 하이브리드 사장교 바닥판 접합부의 철근 이음방법에 따른 구조적 성능을 평가하였다. 바닥판의 접합부에 적용할 수 있는 철근 이음을 형상에 따라 RC 부재에 적용하고, 이에 대한 비선형 해석을 통해 구조적 성능을 예측하였다. 또한 600 m급 사장교를 선정하여 단면력 해석을 통해 접합부에서 발생하는 부착 응력의 크기를 파악하고, 이를 접합부 형상에 따른 부착 강도의 크기와 비교하여 구조적 성능을 평가하였다. 해석 결과, 접합부 철근의 형상에 따라 U형 루프 타입이 가장 큰 하중을 견딜 수 있고, 직선형 타입이 가장 큰 부착 강도를 발현하는 것으로 예측되었다. 또한, 세 가지 형상의 접합부 철근 모두 초고성능 콘크리트의 사장교의 완성계에서 요구되는 부착 성능을 만족시켰다.

Validity of the Nielsen-type hanger arrangement in spatial arch bridges with straight decks

  • Mirian Canovas-Gonzalez;Juan M. Garcia-Guerrero;Juan J. Jorquera-Lucerga
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.51-69
    • /
    • 2023
  • In tied-arch bridges, a properly designed connection between the arch and the deck may become crucial, since the forces in the structure may be significantly reduced. This implies substantial material savings and, consequently, cheaper constructions. The introduction of the Nielsen cable arrangement (composed of V-shaped inclined hangers) in the last century was a milestone because it was able to reduce deflections and bending moments both in the arch and in the deck. So far, the Nielsen cable arrangement has proven to be successful in traditional vertical arch bridges. However, despite its advantages, it has not been widely applied to spatial arch bridges. Thus, this article analyses the difference between the structural behavior of spatial arch bridges with Nielsen-type cable arrangements with respect to those with classical vertical hanger configurations. The main goal is to verify whether the known effectiveness of the Nielsen cable arrangement for classical arch bridges is still preserved when applied to spatial arch bridges. In order to achieve this objective, and as the first part of our study, a set of different all-steel bridges composed of vertical and inclined arches with straight decks have been compared for both cable arrangements. As a major conclusion, for planar vertical arch bridges, the Nielsen-type cable arrangement is always the most effective. In addition, it also seems that, for spatial arch bridges composed of a straight deck and an inclined arch, it still keeps most of its effectiveness as long as the arch is moderately inclined.

태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가 (An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System)

  • 박찬엄;정진수;한운기;임현성;송영상
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.

PS 강봉으로 일체화된 강합성 라멘교의 거더-교대 접합부의 거동에 관한 실험적 연구 (An Experimental Study on the Girder-Abutment Connection for the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bars)

  • 이상윤;안영수;오민호;정지승;양성돈
    • 콘크리트학회논문집
    • /
    • 제24권4호
    • /
    • pp.453-463
    • /
    • 2012
  • 강합성 라멘교는 교대 일체식 교량과 같이 유지보수의 주된 원인이 되는 신축이음 및 받침이 생략되어 유지관리 및 구조적인 장점을 얻을 수 있는 교량 형식이다. 통상적인 강합성 라멘교는 강재로 제작된 거더의 일부를 교대에 매립하는 형태로 거더와 교대가 일체화된다. 거더를 교대에 매립하는 형태의 거더-교대 접합부는 시공상세가 복잡하고 접합부의 상세에 따라 공사비가 증가하는 원인이 될 수 있다. 최근, 기존 강합성 라멘교의 거더-교대 접합부의 시공상세를 간략화하여 시공효율 향상시킨 PIC 거더교가 제안되었다. PIC 거더교는, 거더를 교대에 매립하는 상세 대신, PS 강봉을 이용하여 거더와 교대를 일체화하는 접합부 상세를 가지고 있다. 이 연구에서는 PIC 거더교의 거더-교대 접합부에 대한 거동을 검토하기 위하여 실물모형실험체를 이용한 정적재하실험을 수행하였다. 실험 결과, PS 강봉에 의해 체결되는 거더-교대 접합부는 충분한 내력을 확보하고 있는 것으로 확인되었다. 다만, 균열에 대한 사용성을 확보하기 위해서는 교대 상부에 발생하는 균열을 제어하기 위한 철근 배근이 필요할 것으로 판단된다.

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF