• 제목/요약/키워드: Cabin Heating

검색결과 37건 처리시간 0.024초

HVAC 작동특성에 따른 자동차 실내 공기질 평가에 관한 수치해석적 연구 (A Numerical Study of the Air Quality Inside Automobiles According to the HVAC System Operating Conditions)

  • 윤성현;서진원;최윤호
    • 한국생산제조학회지
    • /
    • 제23권3호
    • /
    • pp.299-309
    • /
    • 2014
  • When using an automotive heating, ventilation, and air conditioning (HVAC) system, we can obtain fresh outside air while maintaining the interior vehicle temperature. In this study, a correction equation considering experimental data for automotive indoor air leakage is defined to simulate the ratio of fresh air to recirculated air in the automobile cabin. With this correction equation, numerical results are compared with experimental data and validated. The $CO_2$ concentration in the automotive cabin is evaluated by considering various boarding conditions and mass flow rates of the HVAC system. The $CO_2$ concentration model derived in this study is expected to be used to control the effective air conditioning and become a basic research tool for automotive air quality control system development.

차세대 객차용 청정시스템 개발 (Development of Air Cleaning System for Railroad Vehicles)

  • 박덕신;조영민;권순박;박은영;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2109-2113
    • /
    • 2008
  • As the standard of living is higher, the passengers using public transportations desire better qualities of environment as well as more comfortable indoor environment. In case of train, the passengers' comfort in passenger cabin is one of the most important elements to be competitive with other transport systems. The indoor air quality of the cabin should be managed properly, because many passengers travel for a long time in the small space of $144\;m^3$. For proper management of the air quality, the heating, ventilation and air conditioning (HVAC) system is required for the ventilation of the compartment. To maintain comfortable environment in the compartment, the automatic ventilation system is needed to exchange the indoor air with fresh air or clean indoor air. In this study, we investigated the indoor air quality (PM-10, $CO_2$, and VOCs) in the compartment of train. In addition, type and pattern of PM-10 has been analyzed through the clustering analysis. Based on the analysis, we could found that the fine particulate matters in the compartment can be a serious hazard to human. To control the concentration of PM-10 and $CO_2$ air cleaners were developed. Through this study, it is expected that people who take a train will be in a more comfortable environment.

  • PDF

IoT 마이크로 보일러에 대한 기초 연구 (Basic Study on the IoT Micro Boiler)

  • 장성철
    • 사물인터넷융복합논문지
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 2022
  • 본 연구의 개발대상 제품은 선박 및 발전용 EGB(Exhaust Gas Boiler-폐열보일러) 종류로써 디젤 엔진, 가스 엔진, 가스 터빈 등에서 나오는 배기 가스의 여열을 이용하여 물을 가열하여 고온·고압의 증기나 온수를 발생시키는 열회수 장치이다. 발생된 증기나 온수는 선박의 선실 난방 및 온수 시설이나 HFO Heating, 터빈 구동에 필요한 동력원으로 사용된다. 폐열보일러의 원리는 여열을 가진 고온의 배기 가스가 보일러의 Tube를 통과하면서 물을 데우는 역할을 한다. 데워진 물은 스팀 형태로 선실이나 터빈장치로 보내어져 사용하게 되는 구조이다. 본 연구에서는 EGB의 열전달 부품인 관형 튜브를 Plate Tube로 대체하여 열전달 표면을 늘려 효율을 극대화하는데 목표가 있다.

CFD를 이용한 지능형 객차 공기조화시스템 설계 (A Design of Intellectual Air-conditioning System using by CFD)

  • 배상호;박덕신;양우봉;박태영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.177-182
    • /
    • 2004
  • Railroad car is one of major public transportation because of an increase in population and heavy traffic problems. We design the concept with air filtration of HVAC system using CFD, select environment-friendly components and compose intellectual HVAC system. For this object, the research to connect HVAC system which control temperature, humidity, air flow with pollutant controlling system which can deal with particular dust, nasty smell. In case of train, fresh air should be provided continuously for pleasant environment of the cabin every season. The air will control outer dust, inner particular dust, $CO_2$ density by air conditioning, heating, humidity regulating, air filtering and ventilating. Ventilation system on passenger cars should be designed for the health and comfort of the passengers.

  • PDF

Intelligent Air Quality Sensor System with Back Propagation Neural Network in Automobile

  • Lee, Seung-Chul;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.468-471
    • /
    • 2005
  • The Air Quality Sensor(AQS), located near the fresh air inlet, serves to reduce the amount of pollution entering the vehicle cabin through the HVAC(heating, ventilating, and air conditioning) system by sending a signal to close the fresh air inlet door/ventilation flap when the vehicle enters a high pollution area. One chip sensor module which include above two sensing elements, humidity sensor and bad odor sensor was developed for AQS (air quality sensor) in automobile. With this sensor module, PIC microcontroller was designed with back propagation neural network to reduce detecting error when the motor vehicles pass through the dense fog area. The signal from neural network was modified to control the inlet of automobile and display the result or alarm the situation. One chip microcontroller, Atmega128L (ATmega Ltd., USA) was used. For the control and display. And our developed system can intelligently detect the bad odor when the motor vehicles pass through the polluted air zone such as cattle farm.

  • PDF

디젤을 이용한 차량용 히터의 연소특성 (Combustion characteristics of the heater for the vehicle)

  • 이상석;이진석;이도형;석경호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.253-256
    • /
    • 2006
  • Most heater being used in vehicles has been used to a cabin heating by being supplied from a heat loss of the engine coolant for heat source efficiency. Recently, the heat loss is reduced by high efficiency in the engine. It becomes to require the combustion heater that directly bums the heater used in vehicles to provide heat source of the heater. The purpose of this study is to research a burner which will applicate combustion heater by the numerical analysis. There are the 5 different types of burners, which is designed by differently each design of the swirler. N-DODECANE by used the burner fuel is performed by numerical analysis in every 5 burner. The burner's efficiency testing is evaluated on the basis of the Exhaust gas temperature.

  • PDF

철도차량 HVAC시스템의 광플라즈마 성능평가 (Efficiency of Photoplasma of HVAC System for Train)

  • 한환수;전승기;박태영;김봉상;박덕신;권순박
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1293-1296
    • /
    • 2007
  • An amenity requirement of the passenger using public traffic is rising continuously, and also The Ministry of Environment established "Indoor air quality management guidelines in public facilities(Dec. 2006)". To satisfy such requirement, the photoplasma device to decrease VOCs(Volatile Organic Compounds) and suspended bacillus is applied to the underframe mounted HVAC(Heating, Ventilating and Air-Conditioning) system for train. Air purifying method of photoplasma device is optical and chemical reaction that UV-light(wavelength less than 280nm) react with catalyst material(TiO2). To analyze the efficiency of photoplasma in this study, we measured the requirement time for toluene to decease down to 0.3ppm after contaminating the passenger cabin for train to toluene 1ppm.

  • PDF

The Effects of Activities and Working Conditions on Fire Accidents on Construction Sites

  • Yi, Kyoo-Jin
    • 한국건축시공학회지
    • /
    • 제20권4호
    • /
    • pp.383-389
    • /
    • 2020
  • Accidents on construction sites involving fires do not occur as often as accidents involving falls from height or collapses. However, once a fire accident occurs, there is a high risk of a large number of casualties. Fire on construction sites is affected by working conditions and the types of activities the construction workers are engaged in at the sites. This study aims to identify activities and working conditions at construction sites that are vulnerable to fire, and analyse how they correlate with each other and how they affect the causes and consequences of fire accidents at construction sties. I analysed 40 fire accident reports and listed the situations vulnerable to fire at construction sites considering direct causes, activities, and working conditions. The most dangerous combination of fire hazards can be the heating devices used during rest/sleep in the office/cabin/storage during cold weather. The next most hazardous combination can be sparks arising from painting, waterproofing, insulation, plumbing, or welding/melting work in an underground or confined space.

차체 기밀특성이 선루프 성능에 미치는 영향 연구 (Study of Effects of Body Leakage on Performance of a Sunroof)

  • 이영림
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.201-209
    • /
    • 2001
  • Some passenger cars with sunroofs open at tilted positions experience reverse flows into cabin rooms and wind noises much louder compared to other cars. In this study, flows around open sunroofs are numerically studied with the variations of body leakage. The effects of body leakage on ventilation and wind noise of a sun roof are examined, in particular. Furthermore, flow visualization, pressure, and noise measured from wind tunnel and road tests are presented. The results show that too small body leakage results in poor performance of ventilation and generates high wind noise around a sunroof. It is therefore very important to secure an adequate body leakage from the early design stage to achieve better performance of a sunroof as well as passengers' comfort related to HVAC(Heating, Ventilation, and Airconditioning).

  • PDF

노즐 형태의 토출구를 이용한 냉난방 시트 성능에 관한 실험적 연구 (A Experimental Study on the Performance of Climate Control Seats Using the Discharge Port of the Shape of Nozzle)

  • 정정훈;김성철;원종필;노상호;조용석
    • 한국자동차공학회논문집
    • /
    • 제17권3호
    • /
    • pp.110-116
    • /
    • 2009
  • Research for climate control seats is being vigorously pursued because requests for passenger's thermal comfort are increasing. Recently, thermoelectric devices have been applied to automotive seats for both cooling and heating operations. The climate control seats using thermoelectric devices can rapidly control the air temperature passing through the devices and directly affect the thermal comfort of passengers. The performance characteristics of the climate control seats were analyzed by experiments for two different types of a leather covered seat and a mesh applied seat. Experimental results show that the cooling and heating performance for the mesh applied seat by using the discharge port of the shape of nozzle was improved significantly in comparison with that for the leather covered seat. The variation of temperature between the inlet air and the outlet air of the climate control seat for the enhanced mesh applied type was by $-3.5^{\circ}C$ at cooling mode, and was by $15.0^{\circ}C$ at heating mode, after about 30 minutes, respectively. Also, it is possible to provide rapid thermal comfort to passengers sitting on the seat in the vehicle cabin by using the proposed climate control seat.