• Title/Summary/Keyword: CZE

Search Result 13, Processing Time 0.02 seconds

Analysis of Inorganic Acids by Capillary Zone Electrophoresis (Capillary Zone Electrophoresis를 이용한 음이온 동시분석에 관한 연구)

  • Park, Sung-Woo;Jin, Kwang-Ho;You, Jae-Hoon;Kim, Dong-Hwan;Seo, Baeseuk;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.213-221
    • /
    • 1998
  • The determination of inorganic anions by capillary zone electrophoresis is reported. A ten component synthetic mixture of anions of bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, perchlorate, chlorate and chlorite was separated by the capillary column and detected by indirect UV method. The running buffer contained 5 mM ammonium dichromate, 10 mM ammonium acetate, 20 mM diethylenetriamine, 10% methanol solution at pH 9.3. A potential of 15 kV at the cathode (reversed polarity) was utilized for the separation of inorganic anions. A complete separation of anions was achieved in less then 10 min and the applicabilities of the method for the analysis of real samples was demonstrated. We compare the concentration of anions in toluene inhaled humen's urine and in postmortem bloods obtained by capillary zone electrophoresis and ion chromatograph.

  • PDF

Development of analytical method capable of identifying the chemically or biologically oriented variants of human growth hormone by capillary electrophoresis

  • Shin, Hyoung-Goo;Hong, Sung-Tae;Son, Jae-Woon;Youn, Yu-Seok;Han, Hye-Seon;Lee, Kang-Choon
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.230.3-231
    • /
    • 2003
  • The therapeutic use of protein pharmaceuticals produced by recombinant DNA technology is increasing in recent decades. In order to investigate the quality of recombinant proteins, it is important to identify and assign the impurities produced in the process of recombination or in storage conditions. Capillary Electrophoresis is emerging technology exhibiting high sensitivity, selectivity and speed and may be most powerful tools for this application. In this study, human growth hormone (hGH) has been analyzed by various mode of capillary electrophoresis such as capillary zone electrophoresis (CZE), capillary gel electrophoresis (CGE), and capillary isoelectric focusing (cIEF) to indicate the chemically or biologically oriented variants and the degraded fragments. (omitted)

  • PDF

Isotachophoretically Assisted On-Line Complexation of Trace Metal Ions in a Highly Saline Matrix for Capillary Electrophoresis

  • Kim, Ji-Hye;Choi, Ki-Hwan;Cho, Sun-Young;Riaz, Asif;Chung, Doo-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.790-794
    • /
    • 2012
  • Trace metal ions such as $Cd^{2+}$, $Ni^{2+}$, and $Zn^{2+}$ in a highly saline sample were subjected to on-line complexation with 4-(2-thiazolylazo) resorcinol (TAR) dissolved in a background electrolyte (BGE) under transient isotachophoresis (TITP) conditions. A long plug of the saline sample, containing the trace metal ions but devoid of TAR, was injected into a coated capillary filled with a BGE composed of 150 mM 2-(cyclohexylamino) ethanesulfonic acid (CHES) and 110 mM triethylamine (TEA) at pH 9.7. Since the electrophoretic mobility of TAR fell between the mobilities of the anionic leading electrolyte ($Cl^-$ in the sample) and the anionic terminating background electrolyte ($CHES^-$), a highly concentrated zone of TAR from the BGE was formed at the rear of the sample matrix and then the metal cations toward the cathode were swept by isotachophoretically assisted on-line complexation (IAOC) between the metal ions and the isotachophoretically stacked TAR. As a result, anionic metal-TAR complexes were formed efficiently, which satisfy the TITP conditions between $Cl^-$ and $CHES^-$. The enrichment factors of metal ions including $Cd^{2+}$ were up to 780-fold compared to a conventional CZE mode using absorbance detection. The detection limits were 17 nM, 15 nM, and 27 nM for $Ni^{2+}$, $Zn^{2+}$, and $Cd^{2+}$ in a 250 mM NaCl matrix, respectively. Our method was successfully applied to the analysis of urine samples without desalting.