• Title/Summary/Keyword: CYFRA 21-1

Search Result 30, Processing Time 0.042 seconds

Clinical Utility of Haptoglobin in Combination with CEA, NSE and CYFRA21-1 for Diagnosis of Lung Cancer

  • Wang, Bing;He, Yu-Jie;Tian, Ying-Xing;Yang, Rui-Ning;Zhu, Yue-Rong;Qiu, Hong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9611-9614
    • /
    • 2014
  • Purpose: To investigate the clinical value in lung cancer of a combination of four serum tumor markers, haptoglobin (Hp), carcinoembryonic antigen (CEA), neuron specific enolase (NSE) as well as the cytokeratin 19 fragment (CYFRA21-1). Materials and Methods: Serum Hp (with immune-turbidimetric method), CEA, NSE, CYFRA21-1 (with chemiluminescence method) level were assessed in 193 patients with lung cancer, 87 patients with benign lung disease and 150 healthy controls. Differences of expression were compared among groups, and joint effects of these tumor markers for the diagnosis of lung cancer were analyzed. Results: Serum tumor marker levels in patients with lung cancer were obviously higher than those with benign lung disease and normal controls (p<0.01). The sensitivities of Hp, CEA, NSE and CYFRA21-1 were 43.5%, 40.9%, 23.3% and 41.5%, with specificities of 90.7%, 99.2%, 97.9% and 97.9%. Four tumor markers combined together could produce a positive detection rate of 85.0%, significantly higher than that of any single test. With squamous carcinomas, the positive detection rates with Hp and CYFRA21-1 were higher than that of other markers. In the adenocarcinoma case, the positive detection rate of CEA was higher than that of other markers. For small cell carcinomas, the positive detection rate of NSE was highest. The area under receiver operating characteristic curve ($AUC^{ROC}$) of Hp in squamous carcinoma (0.805) was higher than in adenocarcinoma (0.664) and small cell carcinoma (0.665). Conclusions: Hp can be used as a new serum tumor marker for lung cancer. Combination detection of Hp, CEA, NSE and CYFRA21-1 could significantly improve the sensitivity and specificity in diagnosis of lung cancer, and could be useful for pathological typing.

Pathologic Correlation of Serum Carcinoembryonic Antigen and Cytokeratin 19 Fragment in Resected Nonsmall Cell Lung Cancer

  • Lee, Seokkee;Lee, Chang Young;Kim, Dae Joon;Hong, Dae Jin;Lee, Jin Gu;Chung, Kyung Young
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.192-196
    • /
    • 2013
  • Background: This study focused on the association between preoperative serum carcinoembryonic antigen (CEA) and cytokeratin 19 fragment (Cyfra 21-1) levels and pathologic parameters in patients with resected non-small-cell lung cancer (NSCLC). Materials and Methods: The records of 527 patients who underwent pulmonary resection of NSCLC were reviewed. The association between preoperative serum CEA and Cyfra 21-1 levels and variables that had p-values of less than 0.05 in a t-test or one-way analyses of variance was analyzed by multiple linear regression. Results: The mean serum CEA and Cyfra 21-1 levels prior to surgery were $6.8{\pm}23.1$ mg/dL (range, 0.01 to 390.8 mg/dL) and $5.4{\pm}12.3$ mg/dL (range, 0.65 to 140.2 mg/dL). The serum CEA levels were associated with tumor (T) and lymph node (N) stage and histology. The serum Cyfra 21-1 levels were associated with T stage, tumor size, and histology. Multiple linear regression indicated that serum CEA levels were associated with T (T3/4 vs. T1: ${\beta}$=8.463, p=0.010) and N stage (N2/3 vs. N0: ${\beta}$=9.208, p<0.001) and histology (adenocarcinoma vs. squamous cell: ${\beta}$=6.838, p=0.001), and serum Cyfra 21-1 levels were associated with tumor size (${\beta}$=2.579, p<0.001) and histology (squamous cell vs. adenocarcinoma: ${\beta}$=4.420, p=0.020). Conclusion: Serum CEA level was correlated with T and N stage, and Cyfra 21-1 with tumor size. CEA and Cyfra 21-1 showed histologic correlation. CEA is mainly elevated in adenocarcinoma and Cyfra 21-1 in squamous cell carcinoma. These results might be helpful for predicting pathologic status in preoperative NSCLC.

Clinical Observations on the Association Between Diagnosis of Lung Cancer and Serum Tumor Markers in Combination

  • Wang, Wen-Jing;Tao, Zhen;Gu, Wei;Sun, Li-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.7
    • /
    • pp.4369-4371
    • /
    • 2013
  • Objective: To evaluate the association of a diagnosis of lung cancer and combined detection of serum carcinoembryonic antigen (CEA), carbohydrateantigen 19-9 (CA19-9), neuron specific enolase (NSE) as well as the cytokeratin 19 fragment (CYFRA21-1). Methods: Serum CEA, CA19-9, NSE and CYFRA21-1 were assessed in 150 patients with lung cancer, 100 patients with benign lung disease and 100 normal control subjects, and differences of expression were compared in each group, and joint effects of these tumor markers in the diagnosis of lung cancer were analyzed. Results: Serum CEA, CA19-9, NSE and CYFRA21-1 in patients with lung cancer were significantly higher than those with benign lung disease and normal controls (p<0.01). It is suggested that these four tumor markers combined together could produce a positive detection rate of 90.2%, significantly higher than that of any single test. Conclusion: Combination detection of CEA, CA19-9, NSE and CYFRA21-1 could significantly improve the sensitivity and specificity in diagnosis of lung cancer, and could be important in early detection.

Preliminary Evaluation of Clinical Utility of CYFRA 21-1, CA 72-4, NSE, CA19-9 and CEA in Stomach Cancer

  • Gwak, Hee Keun;Lee, Jai Hyuen;Park, Seok Gun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.4933-4938
    • /
    • 2014
  • Background: Although various tumor markers have been utilized in management of stomach cancer (SC), only a few reports have described relevance of examples such as CYFRA 21-1 and neuron-specific enolase (NSE). The purpose of this study was to evaluate the potential diagnostic performance of carcinoembryonic antigen (CEA), CA 19-9, CA72-4, CYFRA 21-1 and NSE in patients with SC. Materials and Methods: Ninety-six SC patients with pathologic confirmation between 2012 and 2013 were enrolled. Serum levels of five tumor markers were analyzed using a solid-phase immunoradiometric assay. Receiver operating characteristic (ROC) curves were plotted for the five tumor markers to investigate their diagnostic powers and adjusted cutoff values derived from analysis of ROC curves were evaluated to calculate the sensitivity of each for SC with recommended cutoff values. Results: Based on two different cutoff values (recommended and adjusted), CYFRA 21-1 (${\geq}2.0$ and 1.2 ng/ml) had a respective sensitivity of 50% and 78.1%, compared with 8.3% and 18.8% for CEA (${\geq}7.0$ and 3.9 ng/ml), 15.6% and 18.8% for CA 19-9 (${\geq}37$ and 26.7 ng/ml), 28.1% and 9.6% for CA 72-4 (${\geq}4.0$ and 13 ng/ml) and 7.3% and 7.3% for NSE (${\geq}14.7$ and 15.0 ng/ml) in the initial staging of primary SC. The area under the curve (AUC) for CYFRA 21-1, with a value of 0.978 (95% confidence interval, 0.964-0.991) was comparatively the highest. Univariate analysis revealed significant relationships between tumor marker level and lymph node involvement, metastasis and staging with CYFRA 21-1, CA 72-4 and NSE. Conclusions: CYFRA 21-1 was the most sensitive tumor marker and showed the most powerful diagnostic performance among the five SC tumor markers. NSE and CA 72-4 are significantly related to lymph node involvement, metastasis or stage. Further evaluations are warranted to clarify the clinical usefulness and prognostic prediction of these markers in SC.

Prediction of Lung Cancer Based on Serum Biomarkers by Gene Expression Programming Methods

  • Yu, Zhuang;Chen, Xiao-Zheng;Cui, Lian-Hua;Si, Hong-Zong;Lu, Hai-Jiao;Liu, Shi-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9367-9373
    • /
    • 2014
  • In diagnosis of lung cancer, rapid distinction between small cell lung cancer (SCLC) and non-small cell lung cancer (NSCLC) tumors is very important. Serum markers, including lactate dehydrogenase (LDH), C-reactive protein (CRP), carcino-embryonic antigen (CEA), neurone specific enolase (NSE) and Cyfra21-1, are reported to reflect lung cancer characteristics. In this study classification of lung tumors was made based on biomarkers (measured in 120 NSCLC and 60 SCLC patients) by setting up optimal biomarker joint models with a powerful computerized tool - gene expression programming (GEP). GEP is a learning algorithm that combines the advantages of genetic programming (GP) and genetic algorithms (GA). It specifically focuses on relationships between variables in sets of data and then builds models to explain these relationships, and has been successfully used in formula finding and function mining. As a basis for defining a GEP environment for SCLC and NSCLC prediction, three explicit predictive models were constructed. CEA and NSE are requentlyused lung cancer markers in clinical trials, CRP, LDH and Cyfra21-1 have significant meaning in lung cancer, basis on CEA and NSE we set up three GEP models-GEP 1(CEA, NSE, Cyfra21-1), GEP2 (CEA, NSE, LDH), GEP3 (CEA, NSE, CRP). The best classification result of GEP gained when CEA, NSE and Cyfra21-1 were combined: 128 of 135 subjects in the training set and 40 of 45 subjects in the test set were classified correctly, the accuracy rate is 94.8% in training set; on collection of samples for testing, the accuracy rate is 88.9%. With GEP2, the accuracy was significantly decreased by 1.5% and 6.6% in training set and test set, in GEP3 was 0.82% and 4.45% respectively. Serum Cyfra21-1 is a useful and sensitive serum biomarker in discriminating between NSCLC and SCLC. GEP modeling is a promising and excellent tool in diagnosis of lung cancer.

Evaluation of Usefulness for $Monototal^{TM}$ in Non Small Cell Lung Cancer (비소세포성폐암 환자의 $Monototal^{TM}$ 유용성 평가)

  • Kim, Dae-Woon;Seo, Hyo-Yeol;Jang, Hyun-Young;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.171-174
    • /
    • 2009
  • Purpose: Cancerous death rate 1 place from 2008 year domestic is the lung cancer. The body count which is caused by in the lung cancer every year is increasing. At this lung cancer is the most non small cell lung cancer. $Monototal^{TM}$ test is short reaction time. it is known as the experiment where the example standard of living is high about non small cell lung cancer. This is the study evaluate usefulness of $Monototal^{TM}$ kit. Materials and Methods: $Monototal^{TM}$ were measured using IRMA kit, using 40 CEA positive patients sample which are diagnosed NSCLC, 15 SCC positive patients sample which are diagnosed NSCLC, 40 Cyfra 21-1 positive sample, 20 negative sample in Seoul national university from March to April, 2009. Results: According to result of the $Monototal^{TM}$ test, which is benignancy rate 87.5% in CEA positive patients sample, 93.3% SCC positive patients sample and 100% Cyfra 21-1 positive sample Conclusions: We recommend that using of $Monototal^{TM}$ parallel with different tumor markers. It was useful that diagnosis and convalescence presumption of Non small cell lung cancer.

  • PDF

Diagnostic Value of Serum Cytokeratin 8, 18 and 19 in Lung Cancer (폐암에서 혈중 Cytokeratin 8, 18, 19의 진단적 가치)

  • Choi, Chang Min;Kim, Woo Jin;Oh, Jin Young;Kang, Young Ae;Yoo, Chul Gyu;Lee, Choon Taek;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.388-394
    • /
    • 2003
  • Background : Monoclonal antibodies directed against well-known epitopes on cytokeratin (CK) 8, 18 and 19 (Monototal) have been used in the development of a new diagnostic tool for lung cancer. In the mid-1990s, CK 19 fragments (Cyfra 21-1) became popular and widely used for such diagnosis. This is the first study specifically designed to compare these two markers. Method : The serum levels of CK 8, 18 and 19 were measured using two-site monoclonal/polyclonal immunoradiometric assay kit in 57 healthy adults and 289 patients who were admitted to Seoul National University Hospital from May to September, 2002. The lung cancer group comprised 129 primary lung cancer patients; 116 with non-small cell lung cancer(NSCLC) and 13 with small cell lung cancer (SCLC). The control group comprised 160 non-malignant pulmonary lung disease patients and 57 healthy adults. A total of 166 twin Monototal and Cyfra 21-1 serum assays were obtained; 76 with lung cancer, 70 with non-malignant pulmonary lung disease and 20 healthy adults. Results : The mean serum value of Monototal was $412.47{\pm}455.45U/L$ in NSCLC, $237.08{\pm}145.15U/L$ in SCLC, $126.54{\pm}95.72U/L$ in non-malignant pulmonary lung disease, and $63.68{\pm}31.66U/L$ in healthy adults. The serum values of the lung cancer groups were significantly higher than those of the control group (p<0.01). Using a cut off value of 188U/L, sensitivity and specificity was 66.4% and 81.9% in NSCLC, and 43.8% and 81.9% in SCLC, respectively. The serum levels of CK 8, 18 and 19 were higher in advanced NSCLC than in early stage disease. Conclusion : The serum levels of CK 8, 18 and 19 may be useful in the diagnosis of NSCLC.

Human Lung Cancer Cell Xenografts Implanted under the Capsule of Kidney, Spleen and Liver (폐암 세포주를 사용한 신, 비장 및 간 피막하 분식법의 비교)

  • 김수현;김종인;이해영;조봉균;박성달;김송명
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.711-720
    • /
    • 2003
  • Bakground : Complete resection by the surgery has been selected as the treatment of choice in lung cancer patients, but in cases of recurrence after excision or inoperable cases, the importance of anticancer chemotherapy has been emphasized. If one can select a set of the sensitive chemotherapeutic agents before anticancer chemotherapy, it will give more favourable results. Subrenal capsular assay has been recognized as a useful in-vivo chemosensitivity test of thoracic and abdominal tumors and it can be done in a short time for a rapid interpretation of tumor responsiveness to anticancer chemotherapeutic drugs. It has been reported that various kinds of cancer cells can be implantable to the kidney, but so far there is no comparative study of xenogeneic cell implantation on liver, spleen and kidney. The author implanted the human lung cancer cells under the capsule of S.D rat's liver, spleen and kidney respectively and compared the pattern of growth and histology. Material and Method: After incubation of human lung cancer cell line (SW-900 G IV) in RPMI 1640 (Leibovitz L-15 medium) culture media, 3${\times}$3${\times}$3 mm size fibrin clots which contain 108 cancer cells were made. Thereafter the fibrin clots were implanted at subcapsule area of liver, spleen and kidney of S.D. female rat. For immune suppression, cyclosporin-A (80 mg/Kg) was injected subcutaneously daily from post-implantation first day to sixth day. The body weight was measured at pre and post implantation periods. The growth pattern and the size of tumor mass were observed and the pathologic examination and serum tumor marker tests were performed. Result: Body weight increased in both of control and experimental groups. Serum Cyfra 21-1 was not detected. Serum levels of CEA and NSE revealed no significant change. The SCC-Ag increased significantly in implanted group. The growth rate of human lung cancer cells which was implanted on spleen was higher than on liver or kidney. The surface area, thickness, and volume of tumor mass were predominant at spleen. The success rates of implantation were 80% on kidney, 76.7% on spleen and 43.3% on liver. Pathologic examination of implanted tumors showed characteristic findings according to different organs. Tumors that were implanted on kidney grew in a round shape, small and regular pattern. In the spleen, tumors grew well and microscopic neovascularization and tumor thrombi were also found, but the growth pattern was irregular representing frequent daughter mass. Human lung cancer cells that were implanted in the liver, invaded to the liver parenchyme, and had low success rate of implantation. Microscopically, coagulation necrosis and myxoid fibrous lesion were observed. Conclusion: The success rate of implantation was highest in the kidney. And the mass revealed regular growth that could be measured easily. The SCC-Ag was presented earlier than CEA or Cyfra21-1. The Cyfra21-1 was not detected at early time after implantation. The best model for tumor implantation experiment for chemosensitivity test was subrenal capsular analysis than liver and spleen and the useful serum tumor marker in early period of implantation was the SCC-Ag.