Field Measurement and Analysis of Voltage Unbalance Factor (전압불평형율의 현장측정 및 분석)

  • Jeong, Jong-Ho;Park, Young-Jeen;Lee, Eun-Woong;Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

피로수명 계산용 Off-Line 전산 프로그램 개발

  • 김종석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.526-531
    • /
    • 1997
  • 기존의 발전소 피로수명 평가 프로그램들은 On-Line Fatigue Analysis애 중점을 두고 개발되어 운전 초기부터 Transient모니터링 프로그램이 설치되는 시점까지의 Transient 데이터가 확보되지 않은 오래된 발전소의 경우 전 수명기간 동안의 피로수명 계산에 어려움이 많다. 따라서 본 연구에서는 특별한 경우를 제외하고는 Off-Line 계산을 하는 것이 경제적이고 피로수명 평가에 문제가 되지 않는다고 판단하여 Transient 모니터링을 용해 Transient 종류를 파악하고 이를 데이터베이스화 한뒤 충분한 시간을 가지고 Transient 이력 과 응력데이타를 조합하여 CUF를 계산하는 등 프로그램 기능의 모듈화를 시도하여 필요한 기능을 지속적으로 보완 개발해 나갈 수 있도록 하였다. 본 Software는 국내 원전이 Transient Counting이나 피로분석의 전산화와 관련한 경험이 부족하고 또 외국 프로그램을 도입하여 사용하기에는 과거 데이터가 부족하여 활용에 어려움이 많을 것을 고려하여 기존의 수작업에 의한 Fatigue Evaluation 의 불편함을 보완하고 On-Line Analysis의 필요성과 Off-Line Analysis외 경제성을 적절히 조합하여 현재 발전소 환경에서 가장 적절히 사용할 수 있도록 개발 을 추진하였고 향후 필요한 기능은 지속적으로 보완함으로써 발전소 수명관리에 유용하게 사용될 것이다.

  • PDF

Fatigue Life Evaluation and Optimization for District Heating Pipes Considering Operating Temperature Transition Data (운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 최적화)

  • Ahn M.Y.;Jung S.W.;Lee S.M.;Chang Y.S.;Choi J.B.;Kim Y.J.;Kim S.H.;Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.581-584
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The objectives of this paper are to systematize data processing of transition temperature, investigate its effects on fatigue life of DH pipes and optimization for size of DH pipes. A relational database management system as well as reliable fatigue life evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria. Through the optimum design process, the cross section diminished 18.64% and the CUF diminished 23.35%. So, it can be used as useful information in the future for optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

  • PDF

A Study on Automatic Compensation for Head Lamps Cut-off Line Under Load Variation (차량 하중 변동에 따른 전조등 컷오프라인 자동 보상에 대한 연구)

  • Kim, Ki-Hyeon;Kim, Jun-Hyeon;Byeon, Dong-Kyu;Lee, Dong-Ik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.92-97
    • /
    • 2011
  • Vehicle lightings are very important for safe driving during night time. Since the eye recovery time after an exposure to oncoming headlights would take after several seconds, the aiming point of vehicle head lamps have to pass safety requirements. Despite the fact that vehicle inclination is variable with vehicle load conditions, the head lamps aiming point is usually fixed at a constant position which is set by car manufacturer. Consequently, vehicle head lamps under varying load conditions often make people in the opposing vehicle uncomfortable, and even worse, can cause an accident. This paper presents an active vehicle lighting mechanism to automatically adjust its aiming point, or cut-off line, in order to compensate the change in vehicle inclination resulting from load variations. The effectiveness of the proposed method is demonstrated through a set of simulations and experiments with a real vehicle.

Fatigue Assessment of Reactor Vessel Outlet Nozzle Weld Considering the LBZ and Welding Residual Stress Effect (국부 취화부와 용접 잔류응력 효과를 고려한 원자로 출구노즐 용접부의 피로강도 평가)

  • Lee, Se-Hwan
    • Journal of Welding and Joining
    • /
    • v.24 no.2
    • /
    • pp.48-56
    • /
    • 2006
  • The fatigue strength of the welds is affected by such factors as the weld geometry, microstructures, tensile properties and residual stresses caused by fabrication. It is very important to evaluate the structural integrity of the welds in nuclear power plant because the weldment undergoes the most of damage and failure mechanisms. In this study, the fatigue assessments for a reactor vessel outlet nozzle with the weldment to the piping system are performed considering the welding residual stresses as well as the effect of local brittle zone in the vicinity of the weld fusion line. The analytical approaches employed are the microstructure and mechanical properties prediction by semi-analytical method, the thermal and stress analysis including the welding residual stress analysis by finite element method, the fatigue life assessment by following the ASME Code rules. The calculated results of cumulative usage factors(CUF) are compared for cases of the elastic and elasto-plastic analysis, and with or without residual stress and local brittle zone effects, respectively. Finally, the fatigue life of reactor vessel outlet nozzle weld is slightly affected by the local brittle zone and welding residual stresses.

Development and Application of Detailed Procedure to Evaluate Fatigue Integrity for Major Components Considering Operating Conditions in the Nuclear Power Plant (원전 운전환경을 고려한 주기기 피로 건전성 상세평가 절차개발 및 적용)

  • Kim, Byong-Sup;Kim, Tae-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.20-25
    • /
    • 2006
  • In the design of class 1 components to apply ASME code section III NB, a fatigue is considered as one of the important failure mechanisms. Fatigue analysis procedure and standard fatigue design curve(S-N curve) is suggested in ASME code, which had to be performed to meet the integrity of components at the design step. As the plant life extension for operating power plants and the long-lived plant design, however, are being progressed, the fact which the existing ASME fatigue design curve can not consider fatigue effects sufficiently comes to the fore. To find the technical solution for these problems, a number of researches and discussion are continued up to now. In this study, the detailed fatigue analyses using the 3 dimensional modeling for the fatigue-weakened components were performed to develop the optimized fatigue analysis procedure and their results are compared with other reference solutions.

Effect of Stress Concentration Factors on the Fatigue Evaluation of the Direct Vessel Injection Nozzle (원자로 직접주입노즐의 피로평가에 미치는 응력집중계수의 영향)

  • Kim, Tae-Soon;Lee, Jae-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.53-59
    • /
    • 2010
  • A fatigue damage caused by cyclic load is considered as one of the important failure mechanisms that threaten the integrity of structures and components in a nuclear power plant. In ASME code section III NB, the fatigue analysis procedure and standard S-N curves for the class 1 components are described and these criteria should be met at the design step of components. As the current ASME S-N curves are based on the very conservative assumptions such as a local stress concentration effect, immoderate transient frequencies and a constant Young's modulus, however, they can not precisely address the fatigue behavior of components. In order to find out the technical solution for these problems, a number of researches and discussion have been carried out continuously at home and abroad over the decades. In this study, detailed fatigue analyses for DVI nozzle with various mesh density of finite elements were performed to evaluate effect of stress concentration factors on the fatigue analysis procedure and the excessive conservatism of stress concentration factors are confirmed through the analysis results.

Power Output in Various Types of Solar Panels in the Central Region of Korea (한국 중부 지역의 태양광 모듈 타입에 따른 발전량 특성)

  • Chang, Hyo Sik
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.1
    • /
    • pp.37-44
    • /
    • 2018
  • Solar panels are modules made up of many cells, like the N-type monosilicon, P-type monosilicon, P-type multisilicon, amorphous thin-film silicon, and CIGS solar cells. An efficient photovoltaic (PV) power is important to use to determine what kind of cell types are used because residential solar systems receive attention. In this study, we used 3-type solar panels - such as N-type monosilicon, P-type monosilicon, and CIGS solar cells - to investigate what kind of solar panel on a house or building performs the best. PV systems were composed of 3-type solar panels on the roof with each ~1.8 kW nominal power. N-type monosilicon solar panel resulted in the best power generation when monitored. Capacity Utilization Factor (CUF) and Performance Ratio (PR) of the N-type Si solar panel were 14.6% and 75% respectively. In comparison, N-type monosilicon and CIGS solar panels showed higher performance in power generation than P-type monosilicon solar power with increasing solar irradiance.

Characteristics and Antimicrobial Effects of Novel Burkholderia cepacia No. 15-2 Isolated from Compost (퇴비로부터 분리된 Burkholderia cepacia No.15-2의 특성과 항균 효과)

  • Yun, Soon-Il
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.421-428
    • /
    • 2003
  • To develop the functional-compost containing antifungal substance by using antagonistic microorganisms, Spinacia oleracea L and Rhizoctonia solani Kuhn O-28 were used as a model plant and phytopathogen, respectively. Total 80 strains were isolated from the compost of various waste foods mixture processed for a year. Among them, No.15-2 strain was selected due to its highest antifungal activity against R. solani Kuhn O-28 and was identified phyno- and phylogenotypically as Burkholderia cepacia genomovar V. which is rare probability in pathogen, by 16S rDNA sequencing and specific primer pair PCR method. B. cepacia No.15-2 preferentially dominated during the compost and its cell numbers were maintained almost $${\times}$10^{13}$ cuf/g for 15 days. The morbidity caused by R. solani Kuhn O-28 in S. oleracea L cultivation was reduced to 40% by addition of B. cepacia No.15-2. In conclusion, the antifungal compost using B. cepacia No.15-2 could be applied to biocontrol of various crops blights caused by fungal pathogen.

An On-Line Measurement of Ethanol Concentration by Membrane Gas Sensor (막가스센서에 의한 에탄올 농도의 온라인 측정)

  • 김형찬;박민선
    • KSBB Journal
    • /
    • v.10 no.2
    • /
    • pp.126-130
    • /
    • 1995
  • A membrane gas sensor was developed for the measurement of ethanol concentration during acetic acid fermentation. The fermentation broth including ethanol was permeated through the silicone membrane by synthetic air as a carrier gas and was detected by a semiconductor gas sensor. The optimum conditions of membrane gas sensor were 20m1/min of flow rate and 0.5mm of membrane thickness. In acetic acid fermentation, an on-line measurement of ethanol concentration was conducted by the proposed membrane gas sensor and then the on-line sensor signal, was compared with the result of off-line analysis by gas chromatography. As a result, a correlated response over the range of $0∼70g/\ell$ was shown between membrane gas sensor and gas chromatography and this use of membrane gas sensor was experimentally ascertained for the monitoring and control of bioprocess like acetic acid fermentation.

  • PDF