• Title/Summary/Keyword: CT105

Search Result 120, Processing Time 0.023 seconds

The ability of panoramic radiography in assessing maxillary sinus inflammatory diseases

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.209-213
    • /
    • 2008
  • Purpose : To evaluate the relative diagnostic accuracy of panoramic radiography and Water's projection in maxillary sinus inflammatory diseases by comparing the radiodensities of the images with those of CT. Materials and Methods : Panoramic radiographs, Waters' projection, and CT images from 55 subjects (11O sinuses) were included in this retrospective study. The radiodensity of each maxillary sinus in panoramic radiography was recorded separately as upper and lower divided horizontally by hard palate. In Waters' projection, the overall sinus radiodensity was recorded. The CT images were considered as gold standard. Results : In panoramic radiography, 83 sinuses had same upper and lower radiodensity and 72 of these were consistent with those of CT, 26 sinuses had different upper and lower radiodensity and 15 of these, upper radiodensity was consistent with CT, the remaining 11, lower radiodensity was consistent with CT. One sinus had upper radiolucency with lower radiopacity and both were consistent with those of CT. Altogether 73 (66.4%) among 110 sinuses in panoramic radiography showed full agreement with CT, 26 (23.6%) showed partial agreement with CT. 9 sinuses had no lower image under the hard palate in panoramic radiography due to the smaller size of sinus. In Waters' projection, the radiodensity of 105 sinuses (95.5%) were consistent with that of CT. Conclusion : The panoramic radiography showed 90.0% of the sinus conditions fully or partially which may appear less accurate than that of Water's view (95.5%) but with more detailed information of the inferior part of sinuses. (Korean J Oral Maxillofac Radiol 2008; 38 : 209-13)

  • PDF

Creep Crack Propagation Properties of Rotor Steel under Constant Load and Constant Ct Condition (일정하중 및 일정Ct에서 로터강의 크리프 귤열전파 특성)

  • Jeong, Soon-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.105-111
    • /
    • 2001
  • The creep crack growth properties in 3.3NiCrMoV steel were investigated at 55$0^{\circ}C$ by using CT specimen under constant load and constant Ct condition that was held during crack growth of Imm distance. Ct lelied on load line displacement rate, C*usually increased with crack length though load is reduced in order to maintain constant Ct value as crack growth and appeared scatter band. At constant load and Ct region, crack growth slope was 0.900 and 0.844 each, on the other hand C* slope was 0.480. Fully coalesced area(FCA) ahead of crack tip increased as Ct increase to the critical value, and after that value FCA decreased. For the tertiary creep stage of crack growth test, the most of displacement was due to the steady state creep, except only small part due to the primary creep and other effects. Therefore, tests were mainly interrupted in the tertiary stage to obtain high value of Ct.

  • PDF

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Studies on the Treatment and Prevention of Dementia by Green-Tea extracts (녹차(綠茶)추출물에 의한 치매 치료 및 예방에 관한 연구)

  • Lim, Jong-Soon
    • Journal of Haehwa Medicine
    • /
    • v.12 no.1
    • /
    • pp.11-26
    • /
    • 2003
  • Alzheimer's disease (AD) is characterized by amyloid deposition and associated loss of neunons in brain regions involved in learning and memory processes. Several causes of evidence support that the congnitive disturbance is closed associated with the deficit of cerebral acetylcholine neurotransmission, and the effect of carboxyl terminal 105 amino acid fragment (CT105) of the amyloid precursor protein (APP) on the gene expression of proinflammatory cytokines. We tested it on the scopolamine-induced amnesia model of the ICR mouse using the Morris water maze with repeated orally administration of 1st Green-Tea extract (200 mg/kg) and 2nd Green-Tea extract (200 mg/kg). The Green-Tea prevents impairment of learning and memory and neuronal loss in mouse models of cognitive disturbance and it demonstrated selectivity for inhibition of acetylcholinesterase (AChE). Furthermore, the repeated administration of Green-Tea, CT105-induced alzheimer's mouse model showed central cholinergic activity by ameliorates learning and memory impairment, and isolation of CD14 microglia showed significantly decreases intracellular release of the proinflammatory cytokines tumor necrosis factor-${\alpha}$, interleukin-$1{\beta}$ and reactive oxygen species (ROS). Because of its composite profile, oral therapeutic index and a prophylactic, Green-Tea is considered the better therapeutic candidate for the treatment of Alzheimer's disease.

  • PDF

Clinical outcomes of traumatic brain injury dogs underwent CT or MRI

  • Unghui Kim;Woo-Jin Song
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.2
    • /
    • pp.101-105
    • /
    • 2024
  • Three dogs (7-year-old, neutered male Chihuahua; case 1, 1-year-old, spayed female mixed breed; case 2, 10-month-old, female Maltese; case 3) were referred to Jeju Veterinary Medicine Teaching Hospital for traumatic brain injury. All three patients exhibited abnormal neurological symptoms. The patients were diagnosed through medical history obtained from their caregivers and through computed tomography (CT) or magnetic resonance imaging (MRI) scans. Structural brain abnormalities were observed in two dogs through CT scans and in one dog through MRI. Decompression therapy with mannitol was administered to all three dogs. Case 1, which showed CT findings of pulmonary hemorrhage but no significant brain injury, and case 2, which had mild brain damage on CT imaging, showed improvement in neurological symptoms and gait abnormalities after decompression therapy. However, case 3, which showed suspected brain hemorrhage and brain edema on MRI, did not respond to decompression therapy and was euthanized one month later. Imaging evaluation through CT or MRI in dogs with traumatic brain injury can assist clinical veterinarians in assessing the prognosis of patients.

A Study of the Connection between Achievement Criteria and Computational Thinking in the Areas of Algorithms, Programming and Robotics, and Computing (알고리즘, 프로그래밍, 로봇과 컴퓨팅 영역의 성취 기준과 컴퓨팅 사고력의 관련성 연구)

  • Jeong, Youngsik;Shin, Soobum;Sung, Younghoon
    • Journal of The Korean Association of Information Education
    • /
    • v.21 no.1
    • /
    • pp.105-114
    • /
    • 2017
  • Because the concepts and components of computational thinking included in the Information Education Curriculum and the Software Education Guidelines are different, it has been difficult to establish computational thinking-based software education in schools. Therefore, this study, which is based on the Delphi survey results from 39 experts, we defined computational thinking as 'computing thinking' and separated the components of computational thinking into five main categories: (1) problem definition, (2) data analysis, (3) abstraction, (4) automation, and (5) generalization. In addition, we selected software areas that are strongly related to computational thinking in the KAIE's information Curriculum Standard Model and surveyed experts to decide which computing thinking components are related to the achievement criteria of the software areas.

Improvement of Analytic Reconstruction Algorithms Using a Sinogram Interpolation Method for Sparse-angular Sampling with a Photon-counting Detector

  • Kim, Dohyeon;Jo, Byungdu;Park, Su-Jin;Kim, Hyemi;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.105-110
    • /
    • 2016
  • Sparse angular sampling has been studied recently owing to its potential to decrease the radiation exposure from computed tomography (CT). In this study, we investigated the analytic reconstruction algorithm in sparse angular sampling using the sinogram interpolation method for improving image quality and computation speed. A prototype of the spectral CT system, which has a 64-pixel Cadmium Zinc Telluride (CZT)-based photon-counting detector, was used. The source-to-detector distance and the source-to-center of rotation distance were 1,200 and 1,015 mm, respectively. Two energy bins (23~33 keV and 34~44 keV) were set to obtain two reconstruction images. We used a PMMA phantom with height and radius of 50.0 mm and 17.5 mm, respectively. The phantom contained iodine, gadolinium, calcification, and lipid. The Feld-kamp-Davis-Kress (FDK) with the sinogram interpolation method and Maximum Likelihood Expectation Maximization (MLEM) algorithm were used to reconstruct the images. We evaluated the signal-to-noise ratio (SNR) of the materials. The SNRs of iodine, calcification, and liquid lipid were increased by 167.03%, 157.93%, and 41.77%, respectively, with the 23~33 keV energy bin using the sinogram interpolation method. The SNRs of iodine, calcification, and liquid state lipid were also increased by 107.01%, 13.58%, and 27.39%, respectively, with the 34~44 keV energy bin using the sinogram interpolation method. Although the FDK algorithm with the sinogram interpolation did not produce better results than the MLEM algorithm, it did result in comparable image quality to that of the MLEM algorithm. We believe that the sinogram interpolation method can be applied in various reconstruction studies using the analytic reconstruction algorithm. Therefore, the sinogram interpolation method can improve the image quality in sparse-angular sampling and be applied to CT applications.

Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients

  • Won, Tristan;Lee, Ae-Kyoung;Choi, Hyung-do;Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.98-105
    • /
    • 2021
  • Background: In recent events of the coronavirus disease 2019 (COVID-19) pandemic, computed tomography (CT) scans are being globally used as a complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. It will be important to be aware of major organ dose levels, which are more relevant quantity to derive potential long-term adverse effect, for Korean pediatric and adult patients undergoing CT for COVID-19. Materials and Methods: We calculated organ dose conversion coefficients for Korean pediatric and adult CT patients directly from Korean pediatric and adult computational phantoms combined with Monte Carlo radiation transport techniques. We then estimated major organ doses delivered to the Korean child and adult patients undergoing CT for COVID-19 combining the dose conversion coefficients and the international survey data. We also compared our Korean dose conversion coefficients with those from Caucasian reference pediatric and adult phantoms. Results and Discussion: Based on the dose conversion coefficients we established in this study and the international survey data of COVID-19-related CT scans, we found that Korean 7-year-old child and adult males may receive about 4-32 mGy and 3-21 mGy of lung dose, respectively. We learned that the lung dose conversion coefficient for the Korean child phantom was up to 1.5-fold greater than that for the Korean adult phantom. We also found no substantial difference in dose conversion coefficients between Korean and Caucasian phantoms. Conclusion: We estimated radiation dose delivered to the Korean child and adult phantoms undergoing COVID-19-related CT examinations. The dose conversion coefficients derived for different CT scan types can be also used universally for other dosimetry studies concerning Korean CT scans. We also confirmed that the Caucasian-based CT organ dose calculation tools may be used for the Korean population with reasonable accuracy.

초고속 통신망을 이용한 척추 경나사못 삽입술 Simulator

  • 윤승식;성정환;최희원;김영호;강석호;염진섭
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1999.04a
    • /
    • pp.105-107
    • /
    • 1999
  • 본 연구의 목적은 CT장비로부터 얻어지는 단면 영상을 이용하여 재구성한 3차원 Voxel 정보를 기반으로 의료 시술 중 위험도가 높으며 장기간의 수술 훈련이 필요한 수술인 척추경나사 삽입술에 대한 모의 시술기를 개발하는 것이다. 모의 시술기의 입력은 환자의 환부에 대한 CT와 모의 시술을 해보고자 하는 의사 (사용자)의 입력 (경나사의 진입 위치와 각도)이 되며 출력은 의사들이 시술장에서 받을 수 있는 유일한 방법인 Voxel데이터로부터 재생성된 X-Ray이미지, 혹은 C-Arm의 동영상이며, 최종 결과 출력은 나사못이 삽입된 재구성 CT 이미지들과 3차원 정보를 볼 수 있는 Image Based Rendering의 Image data set이 된다. 본 연구에서는 각 시각화 부분의 특성을 고려하여 direct volume projection, surface modeling, 그리고 최근 많은 관심을 받고 있는 Image Based Rendering 기법을 intergrate하여 사용하였으며 각 시각화 모듈의 초고속 정보 통신망에서의 정보 교환에 대한 방법론에 대해 다루고 있다.

  • PDF

Robotized Percutaneous Biopsy (로봇을 이용한 경피 생체 검사)

  • Son, Jaebum;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.105-113
    • /
    • 2012
  • Biopsy is a type of histopathological examinations, in which a physician samples cells or tissues from a patient's suspicious lesion. Such a lesion frequently resides deep inside human body, and then a percutaneous biopsy is therefore performed using a thick needle with the assistance of medical imaging such as computed tomography(CT) and magnetic resonance imaging(MRI). Recently modern robotic technology is being introduced to percutaneous biopsy in order to reduce any possible human error and hazard on physicians caused by medical imaging. After medical imaging locates the exact location of lesion, an optimization algorithm plans the path for a biopsy needle. Subsequently, a robot system moves the biopsy needle to the lesion in accurate and safe way with the control of a practitioner or automatically. In this article, we try to look into the state-of-art of percutaneous biopsy using such robotic technology. We classified percutaneous biopsy robots by mechanical characteristics and by imaging technology. Then, advantage and disadvantage of each class type are described as well as the basic description, and a few representative designs for each type are introduced. Current research issues of robotized percutaneous biopsy are subjectively selected for the readers' convenience. We emphasize the basic technology of actuator and sensors compatible with imaging technology to conclude this review.