Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image (CT 영상을 이용한 불균질 조직의 선량보정 평가)

  • Kim, Gha-Jung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: In radiation therapy, precise calculation of dose toward malignant tumors or normal tissue would be a critical factor in determining whether the treatment would be successful. The Radiation Treatment Planning (RTP) system is one of most effective methods to make it effective to the correction of dose due to CT number through converting linear attenuation coefficient to density of the inhomogeneous tissue by means of CT based reconstruction. Materials and Methods: In this study, we carried out the measurement of CT number and calculation of mass density by using RTP system and the homemade inhomogeneous tissue Phantom and the values were obtained with reference to water. Moreover, we intended to investigate the effectiveness and accuracy for the correction of inhomogeneous tissue by the CT number through comparing the measured dose (nC) and calculated dose (Percentage Depth Dose, PDD) used CT image during radiation exposure with RTP. Results: The difference in mass density between the calculated tissue equivalent material and the true value was ranged from $0.005g/cm^3\;to\;0.069g/cm^3$. A relative error between PDD of RTP and calculated dose obtained by radiation therapy of machine ranged from -2.8 to +1.06%(effective range within 3%). Conclusion: In conclusion, we confirmed the effectiveness of correction for the inhomogeneous tissues through CT images. These results would be one of good information on the basic outline of Quality Assurance (QA) in RTP system.

  • PDF

IMPROVEMENT OF DOSE CALCULATION ACCURACY ON kV CBCT IMAGES WITH CORRECTED ELECTRON DENSITY TO CT NUMBER CURVE

  • Ahn, Beom Seok;Wu, Hong-Gyun;Yoo, Sook Hyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • To improve accuracy of dose calculation on kilovoltage cone beam computed tomography (kV CBCT) images, a custom-made phantom was fabricated to acquire an accurate CT number to electron density curve by full scatter of cone beam x-ray. To evaluate the dosimetric accuracy, 9 volumetric modulated arc therapy (VMAT) plans for head and neck (HN) cancer and 9 VMAT plans for lung cancer were generated with an anthropomorphic phantom. Both CT and CBCT images of the anthropomorphic phantom were acquired and dose-volumetric parameters on the CT images with CT density curve (CTCT), CBCT images with CT density curve ($CBCT_{CT}$) and CBCT images with CBCT density curve ($CBCT_{CBCT}$) were calculated for each VMAT plan. The differences between $CT_{CT}$ vs. $CBCT_{CT}$ were similar to those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for HN VMAT plans. However, the differences between $CT_{CT}$ vs. $CBCT_{CT}$ were larger than those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for lung VMAT plans. Especially, the differences in $D_{98%}$ and $D_{95%}$ of lung target volume were statistically significant (4.7% vs. 0.8% with p = 0.033 for $D_{98%}$ and 4.8% vs. 0.5% with p = 0.030 for $D_{95%}$). In order to calculate dose distributions accurately on the CBCT images, CBCT density curve generated with full scatter condition should be used especially for dose calculations in the region of large inhomogeneity.

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.

The Terminal and Internal Hairpin Loops of the ctRNA of Plasmid pJB01 Play Critical Roles in Regulating Copy Number

  • Kim, Sam Woong;Jeong, In Sil;Jeong, Eun Ju;Tak, Je Il;Lee, John Hwa;Eo, Seong Kug;Kang, Ho Young;Bahk, Jeong Dong
    • Molecules and Cells
    • /
    • v.26 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • The plasmid pJB01, a member of the pMV158 family isolated from Enterococcus faecium JC1, contains three open reading frames, copA, repB, and repC. Plasmids included in this family produce counter-transcribed RNA (ctRNA) that contributes to copy number control. The pJB01 ctRNA, a transcript which consists of 54 nucleotides (nts), is encoded on the opposite strand from the copA/repB intergenic region and partially overlaps an atypical ribosome binding site (ARBS) for repB. The ARBS is integrated by the two underlined conserved regions: 5'-TTTTTGTNNNNTAANNNNNNNNNATG-3', and the ctRNA is complementary only to the 5' conserved sequence 5'-TTTTTGT-3'. This complementary sequence is located at a distance from the terminal loop of the ctRNA secondary structure. The ctRNA structure predicted by the mfold program suggests the possible generation of a terminal and an internal hairpin loop. The amount of in vitro translation product of repB mRNA was inversely proportional to the ctRNA concentration. Mutations in the terminal and internal hairpin loops of the ctRNA had inhibitory effects on its binding to the target mRNA. We propose that the intact structures of the terminal and internal hairpin loops, respectively, play important roles in forming the initial kissing and extending complexes between the ctRNA and target mRNA and that these regulate the copy number of this plasmid.

Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study (토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험)

  • Daegun, Kim;Jaehong, Jung;Sungchul, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.709-718
    • /
    • 2022
  • We evaluated the effect of high-density aluminum, titanium, and steel metal inserts on computed tomography (CT) numbers and radiation treatment plans for Tomotherapy. CT images were obtained using a cylindrical TomoPhantom comprising cylindrical rods of various densities and metal inserts. Three CT image sets were evaluated for image quality as the mean CT number and standard deviation. Dose evaluation also performed. The reference values did not significantly differ between the CT image sets with the corrected metal inserts. The higher-density material exhibited the largest difference in the mean CT number and standard deviation. The conformity index at Iterative-Metal Artifact Reduction (iMAR) was approximately 20% better than that of non-iMAR. No significant target or organ at risk dose difference was observed between non-iMAR and iMAR. Therefore, iMAR is helpful for target or organ at risk delineation and for reducing uncertainty for three-dimensional conformal radiation therapy in Tomotherapy.

Analysis of utilization and profit for CT and MRI after implementation of insurance coverage for CT (CT 보험급여 전후의 CT 및 MRI검사의 이용량과 수익성 변화)

  • Suh, Chong-Rock;Yu, Seung-Hum;Chun, Ki-Hong;Nam, Chung-Mo
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • In order to analyze the shifts in the volume and profits of Computed Tomography(CT) and Magnetic Resonance Imaging(MRI) utilization for a year before and after the implementation of insurance coverage for CT, this study has been undertaken examining CT and MRI cost data from 'Y' University Hospital situated in Seoul, Korea. Following are the results of this study: 1. The medical insurance payment for CT, implemented on January 1, 1996, increased CT utilization from January 1996 to April 1996 due to low insurance premiums: however, from May 1996 the number of CT cases significantly decreased as a result of strengthened medical cost reviews and the new 'Detailed standards for approval of CT' announced near the end of April 1996 by the insurer. 2. Since the implementation of insurance coverage for CT, CT fee reduction rates for reimbursements by the insurer to the hospital were 50% and 40% for January and February, respectively, and 31% and 15% for March and April. A significant point in the lowering of the reduction rate was reached in May at 11%; furthermore, since June the reduction rate fell below the average reduction rate for reimbursements for all procedures. If the 'Detailed standards for approval of CT' had been announced before the implementation of insurance coverage for CT, CT utilization would not have been so high due to the need to meet those 'standards'. In addition, loss of hospital profits resulting from the reduction for reimbursements would not have occurred. 3. The shifts in MRI utilization showed that there was no particular change with the beginning of insurance coverage for CT, and the introduction of the 'Detailed standards for approval of CT' made MRI utilization increase because MRI is free of restrictions imposed by the insurer. 4. The relationship between CT utilization and MRI utilization showed that they were supplementary to each other before insurance coverage for CT, but that CT was substituted for MRI because of strengthened medical cost reviews after t~e beginning of insurance coverage for CT. 5. The shifts in volume by patient characteristics showed that the number of inappropriate case patients, according to the insurer's "Standards for approval", decreased more than the number of appropriate case patients after the introduction of insurance coverage for CT. Therefore, the health insurance fee schemes for CT have influenced patient care. 6. The shifts in profits from CT utilization showed a net profit decrease of 31.6%. In order to match the pre-coverage profit level, 5,471 more cases would need to be seen and productivity would need to be increased by 32.7%. This profit decrease resulted from a decrease of CT utilization and low reimbursements. With insurance coverage, net profits from CT were 24.4%, and a margin of safety ratio was 39.6%. Because of the net profits and margin of safety ratio, CT utilization fees for insured appropriate cases could not be considered inappropriate. 7. The shifts in profits from MRI utilization before and after the introduction of CT coverage showed that in order to match pre-CT coverage profit levels, 2,011 more cases would need to be seen and productivity would need to be increased by 9.2%. The reasons for needing to increase the number of cases and productivity result from cost burdens created by adding new MRI units. But with CT coverage already begun, MRI utilization increased. Combined with a minor increase in the MRI fee schedule, MRI utilization showed a net profit increase of 18.5%. Net profits of 62.8% and a 'margin of safety ratio' of 43.1% for MRI utilization showed that the hospital relied on this non-covered procedure for profits. 8. The shifts in profits from CT and MRI utilization showed the net profits from CT decreased by 2.33billion Won while the net profits from MRI increased by 815.7million Won. Overall, these two together showed a net profit decrease of 1.51billion Won. The shifts in utilization showed a functional substitutionary relationship, but the shifts in profits did not show a substitutionary relationship. From these results, We can conclude that if insurance is to be expanded to include previously uncovered procedures using expensive medical equipment, detailed standards should be prepared in advance. The decrease in profits from the shifts in coverage and changes in fees is a difficult burden that should be shared, not carried by the hospital alone. Also, a new or improved fee schedule system should include revised standards between items listed and the appropriateness of the fee schedule should constantly be ensured. This study focused on one university hospital in Seoul and is therefore limited in general applicability. But it is valuable for considering current issues and problems, such as the influence of CT coverage on hospital management. Future studies will hopefully expand the scope of the issues considered here.

  • PDF

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Study on a methodology for estimation of void ratio of very fine clayey soil by using micro X-ray CT scan (Micro X-ray CT 촬영을 통한 세립 점성토의 간극비 추정 방법 연구)

  • Heo, Seong-Jun;Kim, Kwang-Yeom;Kwon, Young-Cheul;Kim, Hong-Taek;Shin, Hyu-Soung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.392-403
    • /
    • 2010
  • In this study, a new methodology by using the X-ray CT scan is proposed for estimating void ratio of very fine clayey soil. Since the particle size of the clay is too fine to calculate the volume of void inside the clays, CT scanning tests with a number of clay specimens that were artificially set to have various designated void ratios have been carried out. From the tests, a relationship between the CT values and void ratios is given to be used for estimating the invisible void ratio of very fine clay from a representative CT value scanned. The linear relationship was able to be acquired finally. It is expected that micro X-ray CT scanning can be capable of capturing the void ratio of very fine soils without any errors inherent in the conventional specific gravity tests.

  • PDF

Studies on Quantitative Analysis of Salivary Gland using Computed Tomography (전산화단층사진을 이용한 타액선의 정량분석에 관한 연구)

  • Lee Sang-Chul;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.209-221
    • /
    • 1999
  • Purpose: The purpose of this study was to calculate the size and CT number of both normal parotid and submandibular gland. and evaluate their relation to sex, age and obesity using computed tomography. Materials and Methods: The computed tomography was performed parallel to the Frankfurt plane in 46 subjects with healthy salivary gland. The subjects were divided into the three groups (young, middle. old) according to their ages. The size of salivary gland was determined as maximum cross-sectional area and the CT number of salivary gland was determined as the mean CT number of three ROI's. The body mass index was calculated from weight and height. Results: The mean maximum cross-sectional area was 7.79(±1.25)cm² on parotid gland and 4.12(±0.83) cm² on submandibular gland. The mean CT number was -4.43(±23.87) HU on parotid gland and 50.01(±15.63) HU on submandibular gland. There was decreasing pattern of the maximum cross-sectional area of submandibular gland and the CT number of both parotid and submandibular gland according to age(p<0.05). As the body mass index increased. the maximum cross-sectional area of parotid gland increased and CT number of both parotid and submandibular gland decreased(p<0.05). The maximum cross-sectional area of submandibular gland in male was larger than that in female(p<0.05). As the maximum cross-sectional area and CT number of left salivary gland increased. those of right gland increased(p<0.05). Conclusion : Intra-individual differences in salivary gland size and CT number is considered in the age and individual obesity.

  • PDF

A comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy

  • Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Chang, Sei-Kyung;Ko, Seung-Young;Kim, Sung-Jun;Park, Dong-Soo;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The present study compared the difference between intraoperative transrectal ultrasound (iTRUS)-based prostate volume and preplan computed tomography (CT), preplan magnetic resonance imaging (MRI)-based prostate volume to estimate the number of seeds needed for appropriate dose coverage in permanent brachytherapy for prostate cancer. Materials and Methods: Between March 2007 and March 2011, among 112 patients who underwent permanent brachytherapy with $^{125}I$, 60 image scans of 56 patients who underwent preplan CT (pCT) or preplan MRI (pMRI) within 2 months before brachytherapy were retrospectively reviewed. Twenty-four cases among 30 cases with pCT and 26 cases among 30 cases with pMRI received neoadjuvant hormone therapy (NHT). In 34 cases, NHT started after acquisition of preplan image. The median duration of NHT after preplan image acquisition was 17 and 21 days for cases with pCT and pMRI, respectively. The prostate volume calculated by different modalities was compared. And retrospective planning with iTRUS image was performed to estimate the number of $^{125}I$ seed required to obtain recommended dose distribution according to prostate volume. Results: The mean difference in prostate volume was 9.05 mL between the pCT and iTRUS and 6.84 mL between the pMRI and iTRUS. The prostate volume was roughly overestimated by 1.36 times with pCT and by 1.33 times with pMRI. For 34 cases which received NHT after image acquisition, the prostate volume was roughly overestimated by 1.45 times with pCT and by 1.37 times with pMRI. A statistically significant difference was found between preplan image-based volume and iTRUS-based volume (p<0.001). The median number of wasted seeds is approximately 13, when the pCT or pMRI volume was accepted without modification to assess the required number of seeds for brachytherapy. Conclusion: pCT-based volume and pMRI-based volume tended to overestimate prostate volume in comparison to iTRUS-based volume. To reduce wasted seeds and cost of the brachytherapy, we should take the volume discrepancy into account when we estimate the number of $^{125}I$ seeds for permanent brachytherapy.