Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가 (The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography)

  • 이지원;정강교;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.121-126
    • /
    • 2015
  • 다중검출기전산화단층촬영장치(Multi-Detector Computed Tomography; MDCT)를 이용한 뇌혈관 진단을 위해 뇌혈관전산화단층촬영검사(Brain Computed Tomography Angiography; BCTA)검사 시 동일한 조영제 주입 후 관전압 변화에 따라 변화되는 뇌동맥의 CT Number 값을 통해 방사선량과 영상의 질 변화를 알아보고자 하였다. BCTA검사를 받기 위해 내원한 환자 50명을 대상으로 각 25명씩 두 그룹으로 나누어 관전압(A그룹: 80kVp, B그룹: 120kVp)을 제외한 모든 조건을 동일한 조건[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0 mm, Increment 5.0 mm, Delay Time 3.0s, Care Dose 4D(Demension ; D)]으로 하여 검사를 실시하였다. 얻어진 모든 영상에서 좌 대뇌동맥, 우대뇌동맥, 후 대뇌동맥, 뇌 실질조직 등 네 부위에 관심영역(Region of Interest; ROI)을 설정하여 의료영상 저장 전송 시스템(Picture Archiving Communications System; PACS, G3, Infinitt, Korea)에서 CT Number 값을 측정하여 정량적 평가와 정성적 평가, 유효선량을 비교 하였다. BCTA검사에서 얻어진 각각의 영상에서 CT Number를 이용한 영상평가 결과 80kVp로 검사한 영상이 120kVp 검사에 비해 신호 대 잡음비(Signal to Noise Ratio; SNR) 18%, 대조도 대 잡음비(Contrast to Noise Ratio; CNR)가 19%이상 높게 나타났다. 그리고 피폭선량의 경우 관전압 80kVp에서 120kVp를 적용한 영상에 비해 50% 이상 감소됨을 확인할 수 있었다. A그룹(25명)은 관전압 80kVp로 촬영을 하였으며 B그룹(25명)은 관전압 120kVp로 검사를 하여 영상의 화질 및 선량을 비교 평가하였다. 기존의 고관전압과 비교하여 관전압을 낮게 설정하여 검사할 경우 진단에 영향 없이 방사선량을 감소시킬 수 있어 매우 유용하리라 판단된다.

Clinical Applications of Dual-Energy CT

  • Saira Hamid;Muhammad Umer Nasir;Aaron So;Gordon Andrews;Savvas Nicolaou;Sadia Raheez Qamar
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.970-982
    • /
    • 2021
  • Dual-energy CT (DECT) provides insights into the material properties of tissues and can differentiate between tissues with similar attenuation on conventional single-energy imaging. In the conventional CT scanner, differences in the X-ray attenuation between adjacent structures are dependent on the atomic number of the materials involved, whereas in DECT, the difference in the attenuation is dependent on both the atomic number and electron density. The basic principle of DECT is to obtain two datasets with different X-ray energy levels from the same anatomic region and material decomposition based on attenuation differences at different energy levels. In this article, we discuss the clinical applications of DECT and its potential robust improvements in performance and postprocessing capabilities.

X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구 (A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner)

  • 정재용;이충일;민정환;김연래;이성용;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2010
  • CT 촬영 장치를 기반으로 한 MAGAT (Methacrylic Acid, Gelatin gel And THPC) 정상 산소 중합체 겔 선량계의 화합물 조성비와 CT 영상 스캔 인자의 변화에 따른 선량 반응성을 평가하였다. 다양한 농도의 메타크릴산(MAA, MethAcrylic Acid)과 젤라틴을 조성하여 MAGAT 선량계를 제작하고 20 Gy까지의 방사선을 조사하였다. 조사된 겔 선량계는 CT 촬영 장치(Brilliance Big bore scanner, Phillps, Netherlands)를 이용하여 다양한 스캔 인자(관전압, 관전류, 단면두께)로 같은 위치에서 20회까지의 CT 영상을 획득하였다. 획득된 영상으로 $N_{CT}$-선량 반응곡선($N_{CT}$-dose response), 선량 감도(dose sensitivity), 선량 분해능(dose resolution)을 측정, 평가하였다. 각 조성비 별 MAGAT 선량계의 $N_{CT}$-선량 반응곡선에서 메타크릴산과 젤라틴의 양이 증가함에 따라 기울기와 절편이 증가하였다. 선량 감도는 $0.338{\pm}0.08$에서 $0.859{\pm}0.1$까지 나타났고 메타크릴산이 증가, 젤라틴이 감소할수록 증가하였으나 그 변화는 메타크릴산 농도의 증가에 따라 감도가 증가되는 것에 비해 아주 작은 변화를 보였다. 선량 분해능은 약 2.6에서 6 Gy까지 다양하게 나타났으며 감도와 영상 내의 노이즈에 의해 큰 변화를 보였다. 영상 스캔 인자의 변화에 대한 반응곡선은 관전압, 관전류, 단면두께의 변화에 따른 곡선의 기울기와 감도는 큰 변화를 보이지 않았으나 영상 내의 노이즈(평균 CT number의 표준편차)는 위의 3개의 인자가 증가할수록 감소함을 보였다. 본 연구는 CT 촬영장치를 이용한 MAGAT 중합체 겔의 선량 반응성을 평가하여 적정한 조성비와 스캔 인자를 얻을 수 있었으며 CT를 기반으로 한 3차원 선량계를 간단하고 효율적으로 임상에 적용할 수 있을 것으로 사료된다.

비외상성 급성 복부 통증 환자에게 시행한 복부 전산화단층촬 영과 복부 단순 촬영의 적정성 비교 (The Comparison of Appropriateness of Abdominal Computed Tomography (CT) and Abdominal Radiography Imaging Modality for Patients with Acute Nontraumatic Abdominal Pain)

  • 송정흡;염헌규
    • 한국의료질향상학회지
    • /
    • 제24권2호
    • /
    • pp.15-25
    • /
    • 2018
  • Purpose: To compare the Appropriateness of abdominal CT to abdominal radiography as an imaging modality in terms of the diagnostic value, medical costs and decision making times for patients presented to the emergency department with nontraumatic abdominal pain. Methods: This study used the records of 530 cases presented to the emergency department(ED) with nontraumatic abdominal pain from February to March 2012. Imaging modalities were categorized into abdominal radiography and CT (radiography first or CT first) or radiography alone or CT alone. The diagnostic value, total medical costs and effect on decision making time of the each imaging modalities were compared. Especially, in retrospective review, to evaluate the predictability of the abdominal radiography, alit was assumed that all the 530 cases performed that exam as initial imaging. Results: Among 530 cases, 255 cases underwent abdominal radiography only, 28 cases underwent abdominal CT only and the remnant 247 cases underwent abdominal CT with plain abdominal radiography. The diagnostic value was higher in the cases with abdominal CT (268/275, 97.5%) than in the cases with plain abdominal radiography (19/255, 7.5%).The number of cases predicted by abdominal radiography only as initial imaging were 39/530 (7.4%). In cases where the patients performed the abdominal CT as the first imaging modality thereby omitting the abdominal radiography, the total diagnostic imaging fee was lower than in cases with plain abdominal radiography first followed by the abdominal CT (277,140 vs. 284,226(mean, Korean Won)). Although diagnostic value of the plain abdominal radiography as first imaging modality was lower than the abdominal CT, Decision making time, average duration of hospital stay was longer and the total medical costs was higher than abdominal CT. Conclusion: As an imaging modality in the ED for patients with acute nontraumatic abdominal pain, plain abdominal radiography is an avoidable procedure when viewed in terms of the diagnostic value and total medical costs and decision making times comparing with abdominal CT.

CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상 (Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination)

  • 범희남;한재복;송종남;김욱;최남길
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.29-37
    • /
    • 2016
  • CT 조영검사 예약환자의 원활한 검사 진행과 조영검사로 인한 부작용을 줄일 수 있는 전처치 프로세스 시스템을 개발 및 적용하여 CT 조영검사 예약환자의 검사 만족도를 높이고자 하였다. 2014년 1월부터 2014년 2월까지 CT 조영검사를 예약하여 추적검사를 시행했던 2,846명의 환자들 중 예약시간에 검사를 시행하지 못하고 지연된 214명의 환자들을 대상으로 지연사유를 분석한 후 전처치 프로세스 시스템을 구상 및 개발하여 2015년 1월부터 2015년 2월까지 전처치 프로세스 시스템을 이용하여 전처치가 필요한 644명을 대상으로 SMS 전송 시행율, SMS 전송내역, 예약시간 준수율, 예약시간 지연 사유, 예약 시간보다 지연된 시간 등을 분석하였다. 2014년 1~2월 외래 CT 조영검사 예약환자는 2,846명이었고, 그 중 예약시간에 검사를 시행하지 못한 환자는 214건으로, 약 7.52%의 비중을 차지하고 있었다. 예약시간보다 지연된 세부적인 사례는 creatinine 미확인이 98건(46%), creatinine 1.3 이상이 40건(19%), 과거조영제부작용이 34건(16%), 금식 등 전처치 미흡이 25건(11%), 메트포민제제 당뇨약 복용이 4건(2%), 기타 이유가 13건(6%)으로 나타났으며, 평균 지연시간은 creatinine 미확인이 120분, creatinine 1.3이상이 30분, 과거조영제부작용이 40분, 금식 등 전처치 미흡이 120분, 메트포민제제 당뇨약 복용이 30분, 기타 사유가 60분으로 나타났다. 2015년 1월~2 월 전처치 프로세스 시스템을 적용하여 전처치가 필요한 대상자 644명중 SMS 전송시행율은 515건(80%)으로 나타났으며, SMS 전송내역을 분석한 결과 당일 검사가 283건(44%), 진료과 방문이 185건(29%), 전처치 불필요가 47건(7%), 외래과에서 전처치 프로세스 시스템 미확인으로 SMS 전송이 안 된 건수가 129(20%)건으로 나타났다. CT 조영검사 예약시간 준수율은 전체 644건 중 560건(87%)이 예약시간 안에 검사를 시행하였으며, 예약시간보다 지연된 세부적인 사례는 creatinine 미확인이 23건(28%), creatinine 1.3이상이 11건(13%), 과거조영제부작용이 7건(8%), 금식 등 전처치 미흡이 30건(36%), 메트포민제제 당뇨약 복용이 6건(7%), 기타 이유가 7건(8%) 이었다. 예약시간보다 평균 지연된 시간은 creatinine 미확인이 90분, creatinine 1.3이상이 20분, 과거조영제부작용이 30분, 금식 등 전처치 미흡이 120분, 메트포민제제 당뇨약 복용이 30분, 기타 사유가 60분으로 나타났다. 조영제 부작용의 효율적인 관리적 측면과 CT 조영검사 예약시간에 검사가 원활하게 진행될 수 있도록 전처치 프로세스 시스템을 적용해본 결과 적용 전에 비해 전처치 준비 시간이 줄어들고 CT실, 진료실, 채혈실, 주사처치실 등의 방문횟수 및 동선이 줄어들어 CT실을 찾는 고객들의 검사만족도와 의료서비스 향상에 기여가 될 것으로 사료된다.

Sparse-View CT Image Recovery Using Two-Step Iterative Shrinkage-Thresholding Algorithm

  • Chae, Byung Gyu;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제37권6호
    • /
    • pp.1251-1258
    • /
    • 2015
  • We investigate an image recovery method for sparse-view computed tomography (CT) using an iterative shrinkage algorithm based on a second-order approach. The two-step iterative shrinkage-thresholding (TwIST) algorithm including a total variation regularization technique is elucidated to be more robust than other first-order methods; it enables a perfect restoration of an original image even if given only a few projection views of a parallel-beam geometry. We find that the incoherency of a projection system matrix in CT geometry sufficiently satisfies the exact reconstruction principle even when the matrix itself has a large condition number. Image reconstruction from fan-beam CT can be well carried out, but the retrieval performance is very low when compared to a parallel-beam geometry. This is considered to be due to the matrix complexity of the projection geometry. We also evaluate the image retrieval performance of the TwIST algorithm -sing measured projection data.

Identification and Three-Dimensional Characterization of Micropore Networks Developed in Granite using Micro-Focus X-ray CT

  • Choo, Chang-Oh;Takahashi, Manabu;Jeong, Gyo-Cheol
    • 지질공학
    • /
    • 제24권2호
    • /
    • pp.179-189
    • /
    • 2014
  • We analyzed the three-dimensional distribution of micropores and internal structures in both fresh and weathered granite using micro-focus X-ray computed tomography (micro-CT). Results show that the pore radius in fresh granite is mostly in the range of $17-50{\mu}m$, the throat radius is in the range of $5-25{\mu}m$, and the coordination number (CN) of pores is less than 10. In contrast, the pore radius in weathered granite is mostly in the range of $20-80{\mu}m$, the throat radius is in the range of $8-30{\mu}m$, and the CN is less than 12. In general, a positive linear relationship exists between pore radius and CN. In addition, both the size and the density of pores increase with an increasing degree of rock weathering. The size of the throats that connect the pores also increases with an increasing degree of weathering, which induces fracture propagation in rocks. Micro-CT is a powerful and versatile approach for investigating the three-dimensional distributions of pores and fracture structures in rocks, and for quantitatively assessing the degree of pore connectivity.