• Title/Summary/Keyword: CT-LA

Search Result 31, Processing Time 0.031 seconds

Numerical and experimental flow visualization on nasal air flow (비강 내 공기유동에 대한 실험 및 전산유동가시화)

  • Kim, Sung-Kyun;Park, Jun-Hyeong;Huynh, Gwang-Rim
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.498-501
    • /
    • 2008
  • Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal, abnormal, and deformed nasal cavity models cavity models by PIV under both constant and periodic flow conditions. In this time normal and several deformed nasal cavity models, which simulate surgical operation, Turbinectomy, are investigated numerically by the FVM general purpose code and PIV analysis. The comparisons of these results are appreciated. Dense CT data and careful treatment of model surface under the ENT doctor's advice provide more sophisticated cavity models. The Davis (LaVision Co.) code is used for PIV flow analysis. Average and RMS distributions have been obtained for inspirational and expirational nasal airflows in the normal and deformed nasal cavities.

  • PDF

Systematic Design of High-Resolution High-Frequency Cascade Continuous-Time Sigma-Delta Modulators

  • Tortosa, Ramon;Castro-Lopez, Rafael;De La Rosa, J.M.;Roca, Elisenda;Rodriguez-Vazquez, Angel;Fernandez, F.V.
    • ETRI Journal
    • /
    • v.30 no.4
    • /
    • pp.535-545
    • /
    • 2008
  • This paper introduces a systematic top-down and bottom-up design methodology to assist the designer in the implementation of continuous-time (CT) cascade sigma-delta (${\Sigma}{\Delta}$) modulators. The salient features of this methodology are (a) flexible behavioral modeling for optimum accuracy-efficiency trade-offs at different stages of the top-down synthesis process, (b) direct synthesis in the continuous-time domain for minimum circuit complexity and sensitivity, (c) mixed knowledge-based and optimization-based architectural exploration and specification transmission for enhanced circuit performance, and (d) use of Pareto-optimal fronts of building blocks to reduce re-design iterations. The applicability of this methodology will be illustrated via the design of a 12-bit 20 MHz CT ${\Sigma}{\Delta}$ modulator in a 1.2 V 130 nm CMOS technology.

  • PDF

Numerical and Experimental Flow Visualization on Nasal Airflow (비강 내 공기유동에 대한 실험 및 전산 유동가시화)

  • Kim, Sung-Kyun;Park, Joon-Hyung;Huynh, Quang Liem
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.461-467
    • /
    • 2009
  • Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal, abnormal, and deformed nasal cavity models by PIV under both constant and periodic flow conditions. In this time normal and several deformed nasal cavity models, which simulate surgical operation, Turbinectomy, are investigated numerically by the FVM general purpose code and PIV analysis. The comparisons of these results are appreciated. Dense CT data and careful treatment of model surface under the ENT doctor's advice provide more sophisticated cavity models. The Davis (LaVision Co.) code is used for PIV flow analysis. Average and RMS distributions have been obtained for inspirational and expirational nasal airflows in the normal and deformed nasal cavities.

Endovascular Treatment of Congenital Portosystemic Shunt: A Single-Center Prospective Study

  • Ponce-Dorrego, Maria-Dolores;Hernandez-Cabrero, Teresa;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.2
    • /
    • pp.147-162
    • /
    • 2022
  • Purpose: To design a prospective study on endovascular closure of congenital portosystemic shunts. The primary endpoint was to assess the safety of endovascular closure. The secondary endpoint was to evaluate the clinical, analytical and imaging outcomes of treatment. Methods: Fifteen patients (age range: 2 days to 21 years; 10 male) were referred to our center due to congenital portosystemic shunts. The following data were collected prior to treatment: age, sex, medical history, clinical and analytical data, urine trimethylaminuria, abdominal-US, and body-CT. The following data were collected at the time of intervention: anatomical and hemodynamic characteristics of the shunts, device used, and closure success. The following data were collected at various post-intervention time points: during hospital stay (to confirm shunt closure and detect complications) and at one year after (for clinical, analytical, and imaging purposes). Results: The treatment was successful in 12 participants, migration of the device was observed in two, while acute splanchnic thrombosis was observed in one. Off-label devices were used in attempting to close the side-to-side shunts, and success was achieved using Amplatzer™ Ductus-Occluder and Amplatzer™ Muscular-Vascular-Septal-Defect-Occluder. The main changes were: increased prothrombin activity (p=0.043); decreased AST, ALT, GGT, and bilirubin (p=0.007, p=0.056, p=0.036, p=0.013); thrombocytopenia resolution (p=0.131); expansion of portal veins (p=0.005); normalization of Doppler portal flow (100%); regression of liver nodules (p=0.001); ammonia normalization (p=0.003); and disappearance of trimethylaminuria (p=0.285). Conclusion: Endovascular closure is effective. Our results support the indication of endovascular closure for side-to-side shunts and for cases of congenital absence of portal vein.

Estimation of Shoot Development for a Single-stemmed Rose 'Vital' Based on Thermal Units in a Plant Factory System (식물공장 시스템에서 Thermal Units을 이용한 Single-Stemmed Rose 'Vital'의 신초발달 예측)

  • Yeo, Kyung-Hwan;Cho, Young-Yeol;Lee, Yong-Beom
    • Horticultural Science & Technology
    • /
    • v.28 no.5
    • /
    • pp.768-776
    • /
    • 2010
  • This study was conducted to predict number and fresh weight of leaves, and total leaf area of a single-stemmed rose 'Vital' based on the accumulated thermal units, and to develop a model of shoot development for the prediction of the time when the flowering shoot reaches a phenological stage in a plant factory system. The base temperature ($T_b$), optimum temperature ($T_{opt}$), and maximum temperature ($T_{max}$) were estimated by regressing the rate of shoot development against the temperature gradient. The rate of shoot development ($R$, $d^{-1}$) for the phase from cutting to bud break (CT-BB) was best described by a linear model $R_b$ ($d^{-1}$) = -0.0089 + $0.0016{\cdot}temp$. The rate of shoot development for the phase from bud break to harvest (BB-HV) was fitted to the parabolic model $R_h$ ($d^{-1}$) = $-0.0001{\cdot}temp^2$ + $0.0054{\cdot}temp$ - 0.0484. The $T_b$, $T_{opt}$, and $T_{max}$ values were 5.56, 27.0, and $42.7^{\circ}C$, respectively. The $T_b$ value was used in the thermal unit computations for the shoot development. Number of leaves, leaf area (LA), and leaf fresh weight showed sigmoidal curves regardless of the cut time. The shoot development and leaf area model was described as a sigmoidal function using thermal units. Leaf area was described as LA = 578.7 $[1+(thermal units/956.1)^{-8.54}]^{-1}$. Estimated and observed shoot length and leaf fresh weight showed a reasonably good fit with 1.060 ($R^2=0.976^{***}$) and 1.043 ($R^2=0.955^{***}$), respectively. The average thermal units required from cutting to transplant and from transplant to harvest stages were $426{\pm}42^{\circ}C{\cdot}d$ and $783{\pm}24^{\circ}C{\cdot}d$, respectively.

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

Retreatability of two endodontic sealers, EndoSequence BC Sealer and AH Plus: a micro-computed tomographic comparison

  • Oltra, Enrique;Cox, Timothy C.;LaCourse, Matthew R.;Johnson, James D.;Paranjpe, Avina
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: Recently, bioceramic sealers like EndoSequence BC Sealer (BC Sealer) have been introduced and are being used in endodontic practice. However, this sealer has limited research related to its retreatability. Hence, the aim of this study was to evaluate the retreatability of two sealers, BC Sealer as compared with AH Plus using micro-computed tomographic (micro-CT) analysis. Materials and Methods: Fifty-six extracted human maxillary incisors were instrumented and randomly divided into 4 groups of 14 teeth: 1A, gutta-percha, AH Plus retreated with chloroform; 1B, gutta-percha, AH Plus retreated without chloroform; 2A, gutta-percha, EndoSequence BC Sealer retreated with chloroform; 2B, gutta-percha, EndoSequence BC Sealer retreated without chloroform. Micro-CT scans were taken before and after obturation and retreatment and analyzed for the volume of residual material. The specimens were longitudinally sectioned and digitized images were taken with the dental operating microscope. Data was analyzed using an ANOVA and a post-hoc Tukey test. Fisher exact tests were performed to analyze the ability to regain patency. Results: There was significantly less residual root canal filling material in the AH Plus groups retreated with chloroform as compared to the others. The BC Sealer samples retreated with chloroform had better results than those retreated without chloroform. Furthermore, patency could be re-established in only 14% of teeth in the BC Sealer without chloroform group. Conclusion: The results of this study demonstrate that the BC Sealer group had significantly more residual filling material than the AH Plus group regardless of whether or not both sealers were retreated with chloroform.

Effects of Tropical High Tannin Non Legume and Low Tannin Legume Browse Mixtures on Fermentation Parameters and Methanogenesis Using Gas Production Technique

  • Seresinhe, Thakshala;Madushika, S.A.C.;Seresinhe, Y.;La, P.K.;Orskov, E.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.10
    • /
    • pp.1404-1410
    • /
    • 2012
  • In vitro experiments were conducted to evaluate the suitability of several mixtures of high tanniniferous non legumes with low tanniniferous legumes on in vitro gas production (IVGP), dry matter degradation, Ammonia-N, methane production and microbial population. Eight treatments were examined in a randomized complete block design using four non-legumes and two legumes (Carallia integerrima${\times}$Leucaena leucocephala (LL) (Trt 1), C. integerrima${\times}$Gliricidia sepium (GS) (Trt 2), Aporosa lindeliyana${\times}$LL (Trt 3), A. lindeliyana${\times}$GS (Trt 4), Ceiba perntandra${\times}$LL (Trt 5), C. perntandra${\times}$GS (Trt 6), Artocarpus heterophyllus${\times}$LL (Trt 7), A. heterophyllus${\times}$GS (Trt 8). The condensed tannin (CT) content of non legumes ranged from 6.2% (Carallia integerrima) to 4.9% (Ceiba perntandra) while the CT of legumes were 1.58% (Leucaena leucocephala) and 0.78% (Gliricidia sepium). Forage mixtures contained more than 14% of crude protein (CP) while the CT content ranged from 2.8% to 4.0% respectively. Differences (p<0.05) were observed in in vitro gas production (IGVP) within treatments over a 48 h period dominated by C. perntandra${\times}$G. sepium (Trt 6). The net gas production (p<0.05) was also high with Trt6 followed by A. heterophyllus${\times}$L. leucocephala (Trt 7) and A. heterophyllus${\times}$G. sepium (Trt 8). Highest (p>0.05) NH3-N (ml/200 mg DM) production was observed with the A. heterophyllus${\times}$G. sepium (Trt 8) mixture which may be attributed with it's highest CP content. The correlation between IVGP and CT was 0.675 while IVGP and CP was 0.610. In vitro dry matter degradation (IVDMD) was highest in Trt 8 as well. Methane production ranged from 2.57 to 4.79 (ml/200 mg DM) to be synonimous with IVGP. A higher bacteria population (p<0.05) was found in C. perntandra${\times}$G. sepium (Trt 6) followed by Artocarpus heterophyllus+G. sepium (Trt 8) and the same trend was observed with the protozoa population as well. The results show that supplementing high tannin non leguminous forages by incremental substitution of legume forage increased gas production parameters, NH3-N, IVDMD and microbial population in the fermentation liquid. Methane production was not significantly affected by the presence of CT or different levels of CP in forage mixtures. Among non legumes, Ceiba perntandra and Artocarpus heterophyllus performed better in mixture with L. leucocephala and G. sepium.

Surgical treatmetn of aortic dissection(DeBakey type IIIa) -A case report- (대동맥 박리증 (DeBakey type IIIa) 의 수술적 치료 -치험 1례-)

  • Im, Tae-Geun;Choe, Sun-Ho
    • Journal of Chest Surgery
    • /
    • v.24 no.5
    • /
    • pp.522-528
    • /
    • 1991
  • A successful repair of aortic dissection of descending thoracic aorta was performed in a 48 year old man. The patient was visited ER because of abruptly onset chest pain. On admission, Chest film showed mediastinal widening and undertaken chest CT, echocardiogram and angiogram There was evidence of dilation on descending aorta with internal separation of intimal calcification. Aneurysmal sac with dissection was noted from just below left subclavian artery to 2cm above of diaphragm. He underwent thoracotomy and the impending ruptured aneurysm of the aorta was replaced with a Woven Dacron graft[20Yo Albumin preclotted] using LA-femoral bypass. Postoperative course was uneventful.

  • PDF

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.