• Title/Summary/Keyword: CT values

Search Result 685, Processing Time 0.032 seconds

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

Study of the Linkage of the Education System to foster Manpower of Culture Contents (문화콘텐츠 인력양성을 위한 교육시스템의 연동에 관한 연구)

  • 하판덕
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The values of material civilizations that dominated the last century have been replaced with invisible values such as knowledge, information, and culture. The central axis of the world economy is also rapidly shifting from a capital and labor-intensive industry to a knowledge-based industry of software and contents. From the perspective of the industrialization of culture as multinational corporations and dominance and subordination relationships between cultures thereof, and crisis of cultural identity, the issues of support and fostering a culture industry arise. These have become major issues of concern in deciding national policies. In response to this trend, new departments related to culture contents in various universities have been established for fostering manpower in the field and the government policy to foster related human resources. However, actual results have not been currently achieved, despite the increase in quantity. This is due to the fact that the walls between culture contents departments were too high and thus education and fostering excellent human resources have not been properly conducted. It is also due to the obscure direction of education and a deficiency in the system. To cope with these problems, a systematic manpower-fostering education program should be developed through enhancement of the understanding of culture contents via linking education programs with detailed major fields of study. Accordingly, this study aims to identify changes in the current culture contents industry at home and abroad according to digitalization for fostering manpower of culture contents required in a rapidly changing environment of the culture contents industry. Then, it will review what influence has been made on the education system through the identification of personnel types through work flow charts and contents delivery modes following integration, as well as a desirable method to construct culture contents. Therefore, this study is a preliminary study on the means of fostering core personnel in the culture contents industry through linkage with the education system.

  • PDF

STRESS ANALYSIS OF MAXILLARY PREMOLARS WITH COMPOSITE RESIN RESTORATION OF NOTCH-SHAPED CLASSⅤCAVITY AND ACCESS CAVITY ; THREE-DIMENSIONAL FINITE ELEMENT STUDY (쐐기형 5급 와동과 근관와동을 복합레진으로 수복한 상악 소구치에 대한 응력 분석: 3차원 유한요소법적 연구)

  • Lee, Seon-Hwa;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.570-579
    • /
    • 2008
  • The purpose of this study was to investigate the distribution of tensile stress of canal obturated maxillary second premolar with access cavity and notch-shaped class V cavity restored with composite resin using a 3D finite element analysis. The tested groups were classified as 8 situations by only access cavity or access cavity with notch-shaped class V cavity (S or N), loading condition (L1 or L2), and with or without glass ionomer cement base (R1 or R2). A static load of 500 N was applied at buccal and palatal cusps. Notch-shaped cavity and access cavity were filled microhybrid composite resin (Z100) with or without GIC base (Fuji II LC). The tensile stresses presented in the buccal cervical area, palatal cervical area and occlusal surface were analyzed using ANSYS. Tensile stress distributions were similar regardless of base. When the load was applied on the buccal cusp, excessive high tensile stress was concentrated around the loading point and along the central groove of occlusal surface. The tensile stress values of the tooth with class Ⅴ cavity were slightly higher than that of the tooth without class V cavity. When the load was applied the palatal cusp, excessive high tensile stress was concentrated around the loading point and along the central groove of occlusal surface. The tensile stress values of the tooth without class V cavity were slightly higher than that of the tooth with class V cavity.

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

Development of the Aircraft CO2 Measurement Data Assimilation System to Improve the Estimation of Surface CO2 Fluxes Using an Inverse Modeling System (인버스 모델링을 이용한 지표면 이산화탄소 플럭스 추정 향상을 위한 항공기 관측 이산화탄소 자료동화 체계 개발)

  • Kim, Hyunjung;Kim, Hyun Mee;Cho, Minkwang;Park, Jun;Kim, Dae-Hui
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.113-121
    • /
    • 2018
  • In order to monitor greenhouse gases including $CO_2$, various types of surface-, aircraft-, and satellite-based measurement projects have been conducted. These data help understand the variations of greenhouse gases and are used in atmospheric inverse modeling systems to simulate surface fluxes for greenhouse gases. CarbonTracker is a system for estimating surface $CO_2$ flux, using an atmospheric inverse modeling method, based on only surface observation data. Because of the insufficient surface observation data available for accurate estimation of the surface $CO_2$ flux, additional observations would be required. In this study, a system that assimilates aircraft $CO_2$ measurement data in CarbonTracker (CT2013B) is developed, and the estimated results from this data assimilation system are evaluated. The aircraft $CO_2$ measurement data used are obtained from the Comprehensive Observation Network for Trace gases by the Airliner (CONTRAIL) project. The developed system includes the preprocessor of the raw observation data, the observation operator, and the ensemble Kalman filter (EnKF) data assimilation process. After preprocessing the raw data, the modeled value corresponding spatially and temporally to each observation is calculated using the observation operator. These modeled values and observations are then averaged in space and time, and used in the EnKF data assimilation process. The modeled values are much closer to the observations and show smaller biases and root-mean-square errors, after the assimilation of the aircraft $CO_2$ measurement data. This system could also be used to assimilate other aircraft $CO_2$ measurement data in CarbonTracker.

Three dimensional analysis of the upper airway and facial morphology in children with Class II malocclusion using cone-beam computed tomography (Cone-beam CT를 이용한 제II급 부정교합 아동의 상기도 형태에 관한 3차원적 연구)

  • Hong, Ji-Suk;Kim, Dae-Sung;Oh, Kyung-Min;Kim, Yoon-Ji;Lee, Kyu-Hong;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.134-144
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the volumes and areas of the upper airways in children with Class II malocclusion, using three dimensional cone-beam computed tomography (CBCT) and to compare the volumetric and cross-sectional measurements and cephalometric variables to investigate possible relationships between the upper airway and facial morphology. Methods: CBCT scans were obtained from 37 subjects (17 boys and 20 girls; average age, 11.02 years). The upper airway volumes and areas were measured, and compared with cephalometric variables. Results: The area of the PNS-posterior plane ($S_{PP}$) was significantly smaller in the Class II malocclusion group (p < 0.05). Also, the volumetric and cross-sectional measurements were lower in Class II than in Class I malocclusion groups, although the differences were not significant between the two groups (p > 0.05). The Class II malocclusion group showed significantly smaller values of PFH, mandibular body length, pog to N perp and showed larger values of FMA, ANB, and facial convexity than the Class I malocclusion group. The volume of the upper airway in front of PNS point (WN) showed negative correlation with ANB (p < 0.05). Conclusions: The Class II malocclusion group had a narrower upper airway associated with a decreased posterior facial height and a divergent growth pattern than the Class I malocclusion group.

Use of Flattening Filter Free Photon Beams for Off-axis Targets in Conformal Arc Stereotactic Body Radiation Therapy

  • Smith, Ashley;Kim, Siyong;Serago, Christopher;Hintenlang, Kathleen;Ko, Stephen;Vallow, Laura;Peterson, Jennifer;Hintenlang, David;Heckman, Michael;Buskirk, Steven
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.288-297
    • /
    • 2014
  • Dynamic conformal arc therapy (DCAT) and flattening-filter-free (FFF) beams are commonly adopted for efficient conformal dose delivery in stereotactic body radiation therapy (SBRT). Off-axis geometry (OAG) may be necessary to obtain full gantry rotation without collision, which has been shown to be beneficial for peripheral targets using flattened beams. In this study dose distributions in OAG using FFF were evaluated and the effect of mechanical rotation induced uncertainty was investigated. For the lateral target, OAG evaluation, sphere targets (2, 4, and 6 cm diameter) were placed at three locations (central axis, 3 cm off-axis, and 6 cm off-axis) in a representative patient CT set. For each target, DCAT plans under the same objective were obtained for 6X, 6FFF, 10X, and 10FFF. The parameters used to evaluate the quality of the plans were homogeneity index (HI), conformality indices (CI), and beam on time (BOT). Next, the mechanical rotation induced uncertainty was evaluated using five SBRT patient plans that were randomly selected from a group of patients with laterally located tumors. For each of the five cases, a plan was generated using OAG and CAG with the same prescription and coverage. Each was replanned to account for one degree collimator/couch rotation errors during delivery. Prescription isodose coverage, CI, and lung dose were evaluated. HI and CI values for the lateral target, OAG evaluation were similar for flattened and unflattened beams; however, 6FFF provided slightly better values than 10FFF in OAG. For all plans the HI and CI were acceptable with the maximum difference between flattened and unflattend beams being 0.1. FFF beams showed better conformality than flattened beams for low doses and small targets. Variation due to rotational error for isodose coverage, CI, and lung dose was generally smaller for CAG compared to OAG, with some of these comparisons reaching statistical significance. However, the variations in dose distributions for either treatment technique were small and may not be clinically significant. FFF beams showed acceptable dose distributions in OAG. Although 10FFF provides more dramatic BOT reduction, it generally provides less favorable dosimetric indices compared to 6FFF in OAG. Mechanical uncertainty in collimator and couch rotation had an increased effect for OAG compared to CAG; however, the variations in dose distributions for either treatment technique were minimal.

Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Algorithms in Patient Specific VMAT QA

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Background: The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Materials and Methods: Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. Results and Discussion: For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were $97.2%{\pm}2.3%$, and $99.4%{\pm}1.1%$, respectively while those for 15 MV were $98.5%{\pm}0.85%$ and $99.8%{\pm}0.2%$, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. Conclusion: The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device.

Quantification of Serum Free RNA as a Predictive Biomarker for the Response to Chemotherapy in Patients with Lung Cancer: A Pilot Study

  • Um, Soo-Jung;Lee, Su-Mi;Lee, Soo-Keol;Son, Choon-Hee;Ko, Mee-Kyung;Roh, Mee-Sook;Lee, Ki-Nam;Choi, Pil-Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.4
    • /
    • pp.301-306
    • /
    • 2011
  • Background: It is well-known that cell-free nucleic acids rise in patients with many types of malignancies. Several recent experimental studies using cancer cell lines have shown that changes in cell-free RNA are predictive of the response to chemotherapy. The objective of this study was to determine whether quantification of free RNA can be used as a biomarker for clinical responses to chemotherapy in patients with lung cancer. Methods: Thirty-two patients with lung cancer (non-small cell lung cancer, n=24; small cell lung cancer, n=8) were divided into 2 groups according to their responses to chemotherapy (response group, n=19; non-response group, n=13). Blood samples were collected before and after two cycles of chemotherapy. Real-time quantitative RT-PCR was used for transcript quantification of the glyceraldehyde-3-phosphate dehydrogenase gene. Results: The pre chemotherapy values (Response group $41.36{\pm}1.72$ vs. Non-response group $41.33{\pm}1.54$, p=0.78) and post chemotherapy values (Response group $39.92{\pm}1.81$ vs. Non-response group $40.41{\pm}1.47$, p=0.40) for cell free RNA concentrations, expressed as Ct GAPDH (threshold cycle glyceraldehyde-3-phosphate dehydrogenase gene) levels, was not different between the two groups. There was no significant relationship between changes in the cell free RNA level clinical responses after chemotherapy (p=0.43). Conclusion: We did not find a correlation between quantification of serum cell free RNA levels and clinical responses to chemotherapy in patients with lung cancer. Further investigations are needed to determine whether the cell free RNA level is a useful predictor of responses to chemotherapy in patients with lung cancer.

Effects of Remote Ischemic Pre-Conditioning to Prevent Contrast-Induced Nephropathy after Intravenous Contrast Medium Injection: A Randomized Controlled Trial

  • Dihia Belabbas;Caroline Koch;Segolene Chaudru;Mathieu Lederlin;Bruno Laviolle;Estelle Le Pabic;Dominique Boulmier;Jean-Francois Heautot;Guillaume Mahe
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1230-1238
    • /
    • 2020
  • Objective: We aimed to assess the effects of remote ischemic pre-conditioning (RIPC) on the incidence of contrast-induced nephropathy (CIN) after an intravenous (IV) or intra-arterial injection of contrast medium (CM) in patient and control groups. Materials and Methods: This prospective, randomized, single-blinded, controlled trial included 26 patients who were hospitalized for the evaluation of the feasibility of transcatheter aortic valve implantation and underwent investigations including contrast-enhanced computed tomography (CT), with Mehran risk scores greater than or equal to six. All the patients underwent four cycles of five minute-blood pressure cuff inflation followed by five minutes of total deflation. In the RIPC group (n = 13), the cuff was inflated to 50 mm Hg above the patient's systolic blood pressure (SBP); in the control group (n = 13), it was inflated to 10 mm Hg below the patient's SBP. The primary endpoint was the occurrence of CIN. Additionally, variation in the serum levels of cystatin C was assessed. Results: One case of CIN was observed in the control group, whereas no cases were detected in the RIPC group (p = 0.48, analysis of 25 patients). Mean creatinine values at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 88 ± 32 μmol/L, 91 ± 28 μmol/L and 82 ± 29 μmol/L, respectively (p = 0.73) in the RIPC group, whereas in the control group, they were 100 ± 36 μmol/L, 110 ± 36 μmol/L, and 105 ± 34 μmol/L, respectively (p = 0.78). Cystatin C values (median [Q1, Q3]) at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 1.10 [1.08, 1.18] mg/L, 1.17 [0.97, 1.35] mg/L, and 1.12 [0.99, 1.24] mg/L, respectively (p = 0.88) in the RIPC group, whereas they were 1.11 [0.97, 1.28] mg/L, 1.13 [1.08, 1.25] mg/L, and 1.16 [1.03, 1.31] mg/L, respectively (p = 0.93), in the control group. Conclusion: The risk of CIN after an IV injection of CM is very low in patients with Mehran risk score greater than or equal to six and even in the patients who are unable to receive preventive hyperhydration. Hence, the Mehran risk score may not be an appropriate method for the estimation of the risk of CIN after IV CM injection.