• Title/Summary/Keyword: CT values

Search Result 683, Processing Time 0.026 seconds

Properties of Rice Cakes for Topokki with Curry Powder (카레 분말이 첨가된 떡볶이 떡의 품질 특성)

  • Ahn, Jang-Woo
    • Korean journal of food and cookery science
    • /
    • v.25 no.4
    • /
    • pp.467-473
    • /
    • 2009
  • The principal objective of this study was to assess the quality characteristics of Topokki with different amounts of curry powder[0%(CT0), 2%(CT2), 4%(CT4), 6%(CT6) and 8%(CT8)], based on the amount of rice flour. The L values of the uncooked and cooked Topokki decreased significantly with increases in the amount of added curry powder. The a and b values of cooked Topokki increased significantly with increases in the amount of added curry powder. The weight gains(%) of CT0(11.40%), CT2(11.67%) and CT4(10.93%) were significantly higher and the volume increases(%) of CT2(12.53%) and CT4(12.23%) were higher than those of the other samples. Textural properties such as hardness, cohesiveness, springiness and gumminess were also assessed. Our sensory evaluation test demonstrated that the appearance of CT2(4.24), the color of CT2(4.24) and CT4(4.26), the flavor of CT2(4.34) and the overall acceptability of CT2(4.24) and CT4(4.26) were superior to those of the others. CT4, CT6 and CT8 evidenced more profound antimicrobial activities than the others. In conclusion, the addition of $2{\sim}4%$ curry powder to the rice flour proved the most acceptable for the preparation of Topokki with curry powder.

Evaluation of Antioxidant Activity of Cudrania tricuspidata (CT) Leaves, Fruit Powder and CT Fruit in Pork Patties during Storage

  • Kim, Haeun;Chin, Koo Bok
    • Food Science of Animal Resources
    • /
    • v.40 no.6
    • /
    • pp.881-895
    • /
    • 2020
  • The objective of this study was to assess antioxidant activities of leaves and fruit powder of Cudrania tricuspidata (CT) with different particle sizes (crude, 500 ㎛, 150 ㎛), and determine the physicochemical properties and microbial counts of pork patties with various levels of CT fruit powder (CTFP) during refrigerated storage. Total phenolic content of crude leaves had the highest value of 3.54 g/100 g (p<0.05). Overall, CT leaves (CTLP) had higher total phenolic content than CTFP (p<0.05). 1,1-Diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity of CTFP was higher than that of CTLP (p<0.05), which showed higher iron chelating ability and reducing power than CTFP (p<0.05). After pork patties were manufactured with 0.5% and 1.0% of CTFP at 500 ㎛, pH, color values, thiobarbituric acid reactive substance (TBARS), and peroxide values (POV) were then measured. The addition of CTFP into pork patties significantly (p<0.05) increased redness and yellowness values of patties. TBARS values of pork patties containing CTFP were lower (p<0.05) than those of CTFP-0 patties after 10 days of storage. Pork patties added with CTFP showed no significant (p>0.05) difference TBARS values among different storage periods. POV values of pork patties containing CTFP were lower than those of the control from 3 days up to the end of refrigerated storage (p<0.05). These results suggest that CTFP could be used as a natural antioxidant to retard lipid oxidation in meat products during refrigerated storage.

Acclimation temperature influences the critical thermal maxima (CTmax) of red-spotted grouper

  • Rahman, Md Mofizur;Lee, Young-Don;Baek, Hea Ja
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.7
    • /
    • pp.235-242
    • /
    • 2021
  • The present study investigated the critical thermal maxima (CTmax) of red-spotted grouper, Epinephelus akaara under different acclimation temperatures (Tacc). Fish were acclimated at 24℃, 28℃, and 32℃ water temperature for 2 weeks. Water temperature was increased at a rate of 1℃/h and CTmax level was measured following the critical thermal methodology (Paladino et al., 1980). The results showed that CTmax values of E. akaara were 35.61℃, 36.83℃, and 37.65℃ for fish acclimated at 24℃, 28℃, and 32℃, respectively. The acclimation response ratio (ARR) was 0.26. The CTmax values were significantly correlated with body size. Collectively, it is said that the CTmax value of red-spotted grouper can be affected by different adaptation temperature (24℃, 28℃, and 32℃) and the fish acclimated to a higher temperature has a higher CTmax level. Besides, the CTmax value of 35.61℃-37.65℃ indicating the upper thermal tolerance limit for E. akaara under different Tacc (24℃, 28℃, and 32℃). Understanding the thermal tolerance of E. akaara is of ecological importance in the conservation of this species.

Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media (요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.436-443
    • /
    • 2015
  • The purpose of this study was to develop a self-diagnostic linearity quality control techniques of computed tomography (CT) by using measured CT number values from the various concentrations of iodine contrast media (CM) is diluted with distilled water under each condition of the tube voltage. The equipment was used for four-channel MDCT, the iodine concentration were using 300 mgI/ml, 350 mgI/ml, 370 mgI/ml and 400mgI/ml. Dilution of CM in distilled water was increased by each 5% until the maximum CT number values were measured. We applied the tube voltages for 90 kVp, 120 kVp, 140 kVp. As a result, we was obtained to the nearest linearity as 0.993 of correlation coefficient between the iodinated CM from 5% to 25% in 400 mgI/ml and the CT number values by 90 kVp. In conclusion, the proposed self-diagnostic linearity quality assurance technique by using iodine CM can be utilized to replace the AAPM CT performance phantom.

Physio-mechanical and X-ray CT characterization of bentonite as sealing material in geological radioactive waste disposal

  • Melvin B. Diaz;Sang Seob Kim;Gyung Won Lee;Kwang Yeom Kim;Changsoo Lee;Jin-Seop Kim;Minseop Kim
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.449-459
    • /
    • 2023
  • The design and development of underground nuclear waste repositories should cover the performance evaluation of the different components such as the construction materials because the long term stability will depend on their response to the surrounding conditions. In South Korea, Gyeonju bentonite has been proposed as a candidate to be used as buffer and backfilling material, especially in the form of blocks to speed up the construction process. In this study, various cylindrical samples were prepared with different dry density and water content, and their physical and mechanical properties were analyzed and correlated with X-ray CT observations. The main objective was to characterize the samples and establish correlations for non-destructive estimation of physical and mechanical properties through the utilization of X-ray CT images. The results showed that the Uniaxial Compression Strength and the P-wave velocity have an increasing relationship with the dry density. Also, a higher water content increased the values of the measure parameters, especially for the P-wave velocity. The X-ray CT analysis indicated a clear relation between the mean CT value and the dry density, Uniaxial Compression Strength, and P-wave velocity. The effect of the higher water content was also captured by the mean CT value. Also, the relationship between the mean CT value and the dry density was used to plot CT dry densities using CT images only. Moreover, the histograms also provided information about the samples heterogeneity through the histograms' full width at half maximum values. Finally, the particle size and heterogeneity were also analyzed using the Madogram function. This function identified small particles in uniform samples and large particles in some samples as a result of poor mixing during preparation. Also, the μmax value correlated with the heterogeneity, and higher values represented samples with larger ranges of CT values or particle densities. These image-based tools have been shown to be useful on the non-destructive characterization of bentonite samples, and the establishment of correlations to obtain physical and mechanical parameters solely from CT images.

CT Evaluation of Age-Related Changes in Epaxial Muscle Attenuation and Cross-Sectional Area for Sarcopenia and Myosteatosis in Small Breed Dogs

  • Ji Yeong Lee;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.3
    • /
    • pp.182-188
    • /
    • 2023
  • Sarcopenia and myosteatosis can increase the risk of adverse effects in dogs and humans. However, such imaging study results for evaluating sarcopenia and myosteatosis in small dogs have not yet been available. The objective of this study was to assess age-related changes according to the breed in epaxial muscle cross-sectional area (CSA) and fat infiltration using CT to evaluate sarcopenia and age-related myosteatosis in small breed dogs. In 144 dogs (92 Maltese dogs, 27 Poodle dogs, and 25 Shih Tzu dogs), Hounsfield Unit (HU) values and CSA of left epaxial muscle were measured at the thirteenth thoracic vertebral level on non-contrast transverse CT images. Differences in HU values and CSA according to age and breed were analyzed. The geriatric group (≥12 years) had significantly lower HU values of epaxial muscle than mature adult group (2 to 6 years) of all breeds. The geriatric group had significantly lower CSA of epaxial muscle than mature adult and senior groups (7 to 11 years) of Maltese dogs. HU values of epaxial muscle were not significantly different among all age groups of all breeds. Maltese dogs had significantly lower CSA of epaxial muscle than Poodle and Shih Tzu dogs in all age groups. Results of this study showed that as age increased in small breed dogs, muscle mass and density decreased.

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

Evaluation of Cudrania tricuspidata Leaves on Antioxidant Activities and Physicochemical Properties of Pork Patties

  • Cuong, Tran Van;Chin, Koo Bok
    • Food Science of Animal Resources
    • /
    • v.38 no.5
    • /
    • pp.889-900
    • /
    • 2018
  • Characterization and utilization of the bioactive compounds from natural resources is one of the most concerns to maintain quality properties of foods, especially to prevent the oxidation of lipids in meat products. Phytochemical components and antioxidant activities of Cudrania tricuspidata (CT) leaves extracted using various solvents and their effects on physicochemical properties of pork patties during refrigerated storage were measured. The combined solvents of 80% ethanol, 80% methanol and pure double-distilled (dd)-water obtained the higher total phenolic compounds, flavonoids content, and antioxidant activities as compared to the pure solvent alone. Among the individual antioxidant components, catechin was the predominant polyphenol in CT leaves in all extracts. The addition of CT leaves extracts into pork patties showed high antioxidant activities since thiobarbituric acid-reactive substances (TBARS) values of added CT extracts were lower than those of the control (p<0.05). In conclusion, CT leaf phytochemical components displayed antioxidant activity that varied with the extract solvent used. CT extracts were superior to control in retarding lipid oxidation of pork patties, which was evident as reduced TBARS and peroxide values (POV).

Diagnostic Image Feature and Performance of CT and Gadoxetic Acid Disodium-Enhanced MRI in Distinction of Combined Hepatocellular-Cholangiocarcinoma from Hepatocellular Carcinoma

  • Kim, Hyunghu;Kim, Seung-seob;Lee, Sunyoung;Lee, Myeongjee;Kim, Myeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.313-322
    • /
    • 2021
  • Purpose: To find diagnostic image features, to compare diagnostic performance of multiphase CT versus gadoxetic acid disodium-enhanced MRI (GAD-MRI), and to evaluate the impact of analyzing Liver Imaging Reporting and Data System (LI-RADS) imaging features, for distinguishing combined hepatocellular-cholangiocarcinoma (CHC) from hepatocellular carcinoma (HCC). Materials and Methods: Ninety-six patients with pathologically proven CHC (n = 48) or HCC (n = 48), diagnosed June 2008 to May 2018 were retrospectively analyzed in random order by three radiologists with different experience levels. In the first analysis, the readers independently determined the probability of CHC based on their own knowledge and experiences. In the second analysis, they evaluated imaging features defined in LI-RADS 2018. Area under the curve (AUC) values for CHC diagnosis were compared between CT and MRI, and between the first and second analyses. Interobserver agreement was assessed using Cohen's weighted κ values. Results: Targetoid LR-M image features showed better specificities and positive predictive values (PPV) than the others. Among them, rim arterial phase hyperenhancement had the highest specificity and PPV. Average sensitivity, specificity, and AUC values were higher for MRI than for CT in both the first (P = 0.008, 0.005, 0.002, respectively) and second (P = 0.017, 0.026, 0.036) analyses. Interobserver agreements were higher for MRI in both analyses (κ = 0.307 for CT, κ = 0.332 for MRI in the first analysis; κ = 0.467 for CT, κ = 0.531 for MRI in the second analysis), with greater agreement in the second analysis for both CT (P = 0.001) and MRI (P < 0.001). Conclusion: Rim arterial phase hyperenhancement on GAD-MRI can be a good indicator suggesting CHC more than HCC. GAD-MRI may provide greater accuracy than CT for distinguishing CHC from HCC. Interobserver agreement can be improved for both CT and MRI by analyzing LI-RADS imaging features.

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF