• 제목/요약/키워드: CT simulation

검색결과 365건 처리시간 0.028초

핵연료집합체 기계적특성 시험시설 구축과 기능시험 (Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility)

  • 이강희;강흥석;윤경호;양재호
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

변류기를 이용한 자가발전 장치의 설계와 특성 (Design and Properties of a Self Generation Equipment using Current Transformer)

  • 변우봉;김현식;김종령;이해연;이준희;지민권;이진;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.427-428
    • /
    • 2008
  • We have studied design and application about an self generation equipment for underground power transmission cable. The split CT(Current Transformer), which has the applicable underground power transmission cable, was manufactured through electromagnetic simulation of magnetic core. And manufactured the AC-DC converter that supplied stable DC power for PLC modem when current of power line has more than 150A. An self generation equipment using the CT and AC-DC converter get into operation the PLC modem consistently. As a result, the underground power transmission cable was showed the application possibility through the stable communication and network characteristics.

  • PDF

An Adaptive Mutiresolution Estimation Considering the Spatial and Spectral Characteristic

  • Kim, Kwang-Yong;Kim, Kyung-Ok
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.999-1002
    • /
    • 2002
  • In this paper, we proposes an adaptive method for reducing the computational overhead of fine-to-coarse MRME at the finest resolution level by considering for the spatial and spectral characteristics between wavelet decomposition levels simultaneously. As we know, there is high correlation between the adjacent blocks and it can give the very important clue to estimate motion at finest level. So, in this paper, using the initial motion vector and the adjacent motion vector in the coarsest level, we determine the optimal direction that will be minimized the estimation error in the finest level. In that direction, we define the potential searching region within the full searching region that is caused to increase much computational overhead in the FtC method. Last, in that region, we process the efficient 2-step motion estimation. and estimate the motion vector at finest resolution level. And then, this determined motion vector is scaled to coarser resolutions. As simulation result, this method is similar to computational complexity of the CtF MRME method and very significantly reduces that of the FtC MRME method. In addition, they provide higher quality than CtF MRME, both visually and quantitatively

  • PDF

HPGe 검출기의 PENELOPE 전산모사에 의한 특성 분석 (A Germanium Detector Structure PENEL OPE Characteristic Analysis by Computer Simulation)

  • 장은성;장보석
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.73-77
    • /
    • 2015
  • 검출기의 자세한 구조를 알고자 CT 스캐닝을 하였으며 크리스털 형상과 사층에 관한 세부적인 구조를 전산모사 계산법을 이용해 재현하였다. 낮은 에너지의 감마선에 대한 피크 효율이 거리가 작아질수록 감소, 보다 높은 에너지(400 keV) 아상에서의 전체 효율성은 검출기 코어를 조정함으로써 불확도를 줄일 수 있었다. PENELOPE 계산법을 이용해 얻은 공간적 의존성 사이에 적절한 일치점이 달성되었음을 확인 하였다. 이는 크리스털 코어, 모서리와 크리스털 코어의 라운딩을 설명해 주는 매개변수들을 조정함으로써 달성되었다.

CT기반의 소형 풍력발전 시스템 인버터 고장진단 알고리즘 개발 (Development of Inverter fault diagnostic algorithm based on CT for small-sized wind turbine system)

  • 문대선;김성호
    • 한국지능시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.767-774
    • /
    • 2011
  • 최근 풍력발전 시스템은 가장 빨리 발전하고 있는 신재생 에너지원중 하나로 각광을 받고 있으며, 세계 선진 국가들뿐만 아니라 국내에서도 개발과 보급에 많은 투자를 하고 있다. 풍력발전 시스템은 블레이드, 발전기 및 인버터 등으로 구성된 복잡한 시스템으로 최근 들어 풍력발전 시스템의 각 구성요소의 고장에 대한 연구가 활발히 진행되고 있다. 풍력발전과 관련된 고장진단은 주로 진동센서로부터의 신호처리에 의해 기계적인 고장을 검출 및 진단하는 것이 주를 이루고 있다. 이에 본 연구에서는 풍력발전시스템에 사용되고 있는 인버터의 고장진단에 적용될 수 있는 기법을 제안하고자 한다. 또한 시뮬레이션 및 실제 시스템에의 적용을 통해 제안된 제안된 기법의 유용성을 확인하고자 한다.

A356 합금 시편의 수축공 결함형상에 대한 피로해석용 형상 모델링 방법 (On Shrinkage Cavities Shape Modeling for Fatigue Simulation of A356 Alloy Specimen)

  • 곽시영;조인성
    • 한국주조공학회지
    • /
    • 제39권1호
    • /
    • pp.1-6
    • /
    • 2019
  • During the casting process, it is possible to minimize shrinkage and blowholes by modifying the casting design. However, it is impossible to eliminate these factors completely. Therefore, mechanical design engineers apply a sufficient safety factor owing to the possibility of insufficient performances of the cast products. In this paper, prediction method of the fatigue life of cast products containing shrinkage is conducted by using CT (computed tomography) and the SSM (shape simplification method), and additional fatigue analyses are carried out. The analysis results are then compared to results from actual experiments on samples with shrinkage defects. It is found to be that the considering actual shrinkage in cast products by means of stress and fatigue analyses is more accurate and effective. It is also considered that the proposed hot spot method provides us a good tool to predict the fatigue lifes of cast product.

Performance Analysis Based on RAU Selection and Cooperation in Distributed Antenna Systems

  • Wang, Gang;Meng, Chao;Heng, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권12호
    • /
    • pp.5898-5916
    • /
    • 2018
  • In this paper, the downlink performance of multi-cell distributed antenna systems (DAS) with a single user in each cell is investigated. Assuming the channel state information is available at the transmitter, four transmission modes are formulated as combinations of remote antenna units (RAUs) selection and cooperative transmission, namely, non-cooperative transmission without RAU selection (NCT), cooperative transmission without RAU selection (CT), non-cooperative transmission with RAU selection (NCT_RAUS), and cooperative transmission with RAU selection (CT_RAUS). By using probability theory, the cumulative distribution function (CDF) of a user's signal to interference plus noise ratio (SINR) and the system ergodic capacity under the above four modes are determined, and their closed-form expressions are obtained. Furthermore, the system energy efficiency (EE) is studied by introducing a realistic power consumption model of DAS. An expression for determining EE is formulated, and the closed-form tradeoff relationship between spectral efficiency (SE) and EE is derived as well. Simulation results demonstrate their consistency with the theoretical analysis and reveal the factors constraining system EE, which provide a scientific basis for future design and optimization of DAS.

인공 슬관절 전치환술 시뮬레이션을 위한 형상 모델링 (A Total Knee Arthroplasty Simulation Using 3D Medical Images)

  • 서정우;전용태;박세형;최귀원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.896-902
    • /
    • 2005
  • An orthopedic surgeon normally gets the operational parameters of total knee arthroplasty from medical images(CT, MRI). Anatomical axis, mechanical axis, the width and height of femur, or tibia are the most important parameters related with accomplishment of TKA. This paper presents a methodology of simulation that virtually operates TKA according to 2D medical images. Using this simulator, some important parameters for operation can be achieved before hand. The simulator provides the 3D computational model of a knee joint and then derives the proper size of implant corresponding to the joint. The whole process of TKA can be simulated such as clipping a knee joint, assembling the joint and its implants, visualizing all the operation steps, deriving some crucial parameters such as anatomical axis and cutting thickness, and predicting the result of TKA. Some examples are given and discussed to validate the methodology.

  • PDF

삼상유도전동기의 부하시 토오크 측정에 관한 연구 (A study on the on-load torque measurement for three phase induction motor)

  • 이승원;김은배;황석영;강석윤
    • 전기의세계
    • /
    • 제30권11호
    • /
    • pp.734-746
    • /
    • 1981
  • This paper suggests on-load torque measurement for 3 phase induction motors by input -voltage and current utilizing symmetric coordinate analysis technique on the basis of the induction motor equivalent circuit. In this paper, two cases are treated with, i.e, one is the case where the motors' exciting current and primary leakage impedance voltage drop are compensated automatically, adopting the ideal wattmeter whose current coil impedance and voltage coil impedance are 0 and .inf. respectively, and the other is the case where non-ideal wattmeter is adopted and the compensation above is made by computation. As a result of the case study, following conclusions are obtained. 1) By proper combination of the error propagation law and the limit of power consumption, the desirable overall measurement error of the apparatus can be obtained on the basis of the inherent errors of CT and PT. 2) The measurement error is larger in current simulation circuit than in voltage simulation circuit. 3) Between the two cases, the latter is more advantageous than the former from the viewpoint of feasibility and the measurement error. 4) As the attachment of Ammeter in the current simulation circuit influences the measurement error considerably, its internal impedance should be large considerably. 5) The larger the consumption power of the apparatus is, the easier the feasibility is.

  • PDF

신속 조형 기술로 제작된 인체모형을 이용한 술전 모의 두개악안면성형수술 (3-Dimensional Model Simulation Craniomaxillofacial Surgery using Rapid Prototyping Technique)

  • 정경인;백롱민;임주환;박성규;허찬영;김명국;권순성
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.796-797
    • /
    • 2005
  • In plastic and reconstructive craniomaxillofacial surgery, careful preoperative planning is essential to get a successful outcome. Many craniomaxillofacial surgeons have used imaging modalities like conventional radiographs, computed tomography(CT) and magnetic resonance imaging(MRI) for supporting the planning process. But, there are a lot of limitations in the comprehension of the surgical anatomy with these modalities. Medical models made with rapid prototyping (RP) technique represent a new approach for preoperative planning and simulation surgery. With rapid prototyping models, surgical procedures can be simulated and performed interactively so that surgeon can get a realistic impression of complex structures before surgical intervention. The great advantage of rapid prototyping technique is the precise reproduction of objects from a 3-dimensional reconstruction image as a physical model. Craniomaxillofacial surgeon can establish treatment strategy through preoperative simulation surgery and predict the postoperative result.