• 제목/요약/키워드: CT simulation

검색결과 365건 처리시간 0.037초

3 Dimensional Computer Simulated Cutting Guide for the Mandibuloplasty : A Preliminary Case Report

  • Choi, Jong-Woo;Jeong, Woo Shik;Oh, Tae Suk
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.80-82
    • /
    • 2015
  • The mandibuloplasty for the facial aesthetic reason has been the one of the most popular procedures in aesthetic facial bone surgery in East Asia. Most East Asian women prefer smaller-looking and smooth-shaped facial contour. Prominent mandible angle which are common in Asia would be the main problem for smooth facial contour. In addition, recently, the mandibular body and broad chin shape also are known to be remodeled in order to get the ideal smooth facial shape. However, mandibuloplasty is not that easy to cut because many patients has inward mandibular angle and the visual field in operation is limited. The aim of this trial is to try to provide the prefabricated cutting guide for the symmetric and appropriate mandibuloplasty with the surgeons. Preoperative computed tomography(CT) data were processed for the patient and computer simulation model was produced. Then, mandibuloplasty was done on the computer simulation screen. Based on this data, customized cutting guide was made. This prefabricated cutting guide was used in real mandibuloplasty bilaterally. Premade cutting guide for the mandibuloplasty based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the patients in near future.

Penelope Simulation에 의한 불감층 두께 효과 및 HPGe 검출기 분석 (Analysis of the Dead Layer Thickness effect and HPGe Detector by Penelope Simulation)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.801-806
    • /
    • 2018
  • 게르마늄 결정은 검출에 유용하지 않지만, 광자를 강하게 약화하기 때문에 효율성 저하를 일어키는 불감층을 가지고 있다. 따라서 제조업체가 제공하는 데이터를 검출기 시뮬레이션 모델에 사용하면 계산된 효율성과 측정된 효율성 사이에 약간의 큰 차이가 나타난다. 고순도 게르마늄(HPGe) 검출기의 모양과 치수는 CT 스캔을 통해 몬테카롤롤 시뮬레이션을 위해 형상을 정확하게 형상화하였다. 이 결과 불감층 두께 증가가 효율 감소과정에 미치는 영향을 연구하고자 한다. 불감층의 조정은 50 - 1500 keV의 에너지 범위에서 측정 효율과 시뮬레이션 효율 사이의 ${\pm}3%$의 상대편차와 함께 좋은 일치임을 확인하였다. 불감층 두께에 변화를 주어 시뮬레이션 데이터를 비교하였다. 몬테카롤로 시뮬레이션 결과를 실험 결과와 비교하여 새로운 불감층 두꼐를 얻었다. 1.4와 1.6 mm 두께의 End Cap 시뮬레이션 모델에서 1.5mm 두께의 End Cap시뮬레이션 모델에 대한 불감층 두꼐 결과의 차이는 End Cap 치수의 정확성으로 인한 체계적인 오류였다. 통계적 오류와 체계적 오류를 고려한 후, 검출기의 불감충 두께는 $1.02{\pm}0.14mm$로 도출되었다. 따라서 불감층 두께의 증가는 효율성 감소에 영향을 미치는 것을 확인하였다.

전립선암 환자의 방사선 치료 시 방광 체적 변화 (Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate)

  • 이레나;이지혜;이경자;지영훈
    • Journal of Radiation Protection and Research
    • /
    • 제33권2호
    • /
    • pp.61-65
    • /
    • 2008
  • 목 적: 전립선암 환자의 방사선 치료 시 전립선의 위치 변화 및 비뇨기계 부작용을 줄이기 위해 방광의 체적을 일정하게 유지하도록 한 후 초음파를 이용하여 방광의 체적 변화를 측정 하였다. 대상 및 방법: 2002년 12월부터 2007년 8월 까지 이대 목동병원에서 전립선 암으로 진단받고 근치적 목적의 방사선 치료를 받은 환자 26명을 대상으로 하였다. 13명의 실험군 환자는 방광의 체적을 일정하게 유지하기 위하여 모의조사, CT 스캔, 및 치료 1시간 전에 450 cc의 물을 마시도록 하였다. 나머지 13명의 대조군 환자에 대해서는 특별한 지시를 하지 않았다. 각 환자의 CT영상에서 방광의 체적을 측정하였다. 3차원 입체 조형 치료 계획이 설계되었고 처방선량 70.2 Gy 조사할 경우 방광과 직장의 유효체적을 계산 하였다. 실험군에 속해 있는 환자에 대해 방사선 치료 전 방광의 체적을 초음파를 이용하여 6-8주 간 매주 측정하였고 방광의 체적 변화를 분석하였다. 결과: CT상에서 측정 한 방광의 평균 체적 및 표준 오차는 실험군의 경우 $283.5{\pm}114.0\;cc$ (40%) 이고 대조군의 경우 $181.2{\pm}120.1\;cc$ (66%) 이다. 실험군의 경우 CT 상의 방광 체적과 CT scan 전에 획득한 초음파 영상상의 방광 체적은 통계적으로 유의하지 않으나 상관관계가 있는 것으로 보이고 초음파를 이용하여 측정한 방광의 체적은 CT상에서의 체적의 평균 62% 이다. 실험군에 있어서 초음파 시스템을 이용하여 주간 측정한 방광의 체적의 변화는 상당히 컸으며 최소 33%에서 최대 75%까지 변화 하였다. 결론: CT 스캔 전에 일정한 양의 물을 마시도록 지시한 실험군의 환자들의 경우 대조군대비 평균 방광의 체적을 크게 유지할 수 있었다. 그러나 일정한 양의 물을 마시도록 지시하더라도 6-8주간의 치료 기간 중에 방광의 체적을 일정히 유지 하는데는 어려움이 있었다.

관개지구 물관리기법에 따른 농업용 저수지 공급량 평가 (Impact of Water Management Techniques on Agricultural Reservoir Water Supply)

  • 류정훈;송정헌;강석만;장중석;강문성
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.121-132
    • /
    • 2018
  • Along with climate change, it is reported that the extreme climate events such as severe drought could cause difficulties of agricultural water supply. To minimize such damages, it is necessary to secure the agricultural water resources by using or saving the amount of irrigation water efficiently. The objectives of this study were to develop paddy water management scenarios and to evaluate their effectiveness on water saving. Three water management scenarios (a) deep irrigation with ponding depth of 20~80 mm (control, CT), (b) no/intermittent irrigation until paddy cracks (water management A, WM-A), and (c) intermittent irrigation with ponding depth under 20 mm (water management B, WM-B) were developed. Water saving effects were analyzed using monitored data from experimental paddy fields, and agricultural water supply was analyzed on a reservoir-scale using MASA model. The observed irrigation amounts were reduced by 21 % and 17 % for WM-A and WM-B compared to CT, respectively, and mainly occurred by the increase of effective rainfall. The simulation results showed that water management scenarios could reduce irrigation by 21~51 % and total inflow by 10~24 % compared to CT. The long-term simulated water level change of agricultural reservoir resulted in the decrease of dead level occurrence for WM-A and WM-B. The study results showed that WT-A and WT-B have more benefit than CT in the aspect of agricultural reservoir water supply.

로켓추진을 이용한 고속 수중운동체의 수중 주행성능 측정 결과(II) (Measurement of Performance of High Speed Under Water Vehicle by Using Solid Rocket Motor(II))

  • 윤현걸;이효남;차정민;임설;서석훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.131-136
    • /
    • 2017
  • 고체 로켓추진기관을 이용한 자연공동형 수중운동체를 수중주행 시험하였다. 수중운동체의 속도 및 주행거리를 측정하고, 수중운동체 표면에 압력센서를 설치하여 초공동이 발달됨에 따라 표면 압력이 어떻게 변화하는지를 조사하였으며, 수중카메라를 설치하여 시험시 수중운동체에 초공동이 발생하여 진행하는 과정을 기록하였으며, 이를 이차원 비점성 이론해석법에 근거한 CNU-SuperCT 프로그램을 사용하여 계산한 시뮬레이션 결과와 비교하였다. CNU-SuperCT 프로그램은 수중운동체의 조종면을 포함하지 않고 계산한 것을 고려하면, 시뮬레이션 결과와 측정결과가 잘 맞는다고 판단되며, 수중촬영결과도 이와 동일한 결과를 보인다.

  • PDF

로켓추진을 이용한 고속 수중운동체의 수중 주행성능 측정 결과(II) (Measurement of Performance of High Speed Underwater Vehicle with Solid Rocket Motor(II))

  • 윤현걸;이효남;차정민;임설;서석훈
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.12-17
    • /
    • 2018
  • 고체 로켓추진기관을 이용한 자연공동형 수중운동체를 수중주행 시험하였다. 수중운동체의 속도 및 주행거리를 측정하고, 수중운동체 표면에 설치한 압력센서로 초공동의 발달에 따른 표면 압력 변화를 조사하였고, 수중카메라로 수중운동체에 초공동이 발생하여 진행하는 과정을 기록하였으며, 이를 이차원 비점성 이론해석법에 근거한 CNU-SuperCT 프로그램을 사용하여 계산한 시뮬레이션 결과와 비교하였다. CNU-SuperCT 프로그램은 수중운동체의 조종면을 포함하지 않고 계산하는 것을 고려하면, 시뮬레이션 결과와 측정결과가 잘 맞는다고 판단되며, 수중촬영결과도 이와 동일한 결과를 보인다.

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

THE ADAPTATION METHOD IN THE MONTE CARLO SIMULATION FOR COMPUTED TOMOGRAPHY

  • LEE, HYOUNGGUN;YOON, CHANGYEON;CHO, SEUNGRYONG;PARK, SUNG HO;LEE, WONHO
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.472-478
    • /
    • 2015
  • The patient dose incurred from diagnostic procedures during advanced radiotherapy has become an important issue. Many researchers in medical physics are using computational simulations to calculate complex parameters in experiments. However, extended computation times make it difficult for personal computers to run the conventional Monte Carlo method to simulate radiological images with high-flux photons such as images produced by computed tomography (CT). To minimize the computation time without degrading imaging quality, we applied a deterministic adaptation to the Monte Carlo calculation and verified its effectiveness by simulating CT image reconstruction for an image evaluation phantom (Catphan; Phantom Laboratory, New York NY, USA) and a human-like voxel phantom (KTMAN-2) (Los Alamos National Laboratory, Los Alamos, NM, USA). For the deterministic adaptation, the relationship between iteration numbers and the simulations was estimated and the option to simulate scattered radiation was evaluated. The processing times of simulations using the adaptive method were at least 500 times faster than those using a conventional statistical process. In addition, compared with the conventional statistical method, the adaptive method provided images that were more similar to the experimental images, which proved that the adaptive method was highly effective for a simulation that requires a large number of iterations-assuming no radiation scattering in the vicinity of detectors minimized artifacts in the reconstructed image.

비단열 모세관의 영향을 고려한 냉동 사이클 시뮬레이션 (Simulation of the effects of a non-adiabatic capillary tube on refrigeration cycle)

  • 박상구;손기동;정지환;김윤수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.255-262
    • /
    • 2008
  • The simulation of refrigeration cycle is important since the experimental approach is too costly and time-consuming. The present simulation focuses on the effect of capillary tube-suction line heat exchangers (CT-SLHX), which are widely used in small vapor compression refrigeration systems. The simulation of steady states is based on fundamental conservation equations of mass and energy. These equations are solved simultaneously through iterative process. The non-adiabatic capillary tube model is based on homogeneous two-phase model. This model is used to understand the refrigerant flow behavior inside the non-adiabatic capillary tubes. The simulation results show that both of the location and length of heat exchange section influence the coefficient of performance (COP). These results can be used in either design calculation of capillary tube length for refrigeration cycle or effect of suction line heat exchanging on refrigeration cycle.

  • PDF

폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석 (Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선;정재욱
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.263-268
    • /
    • 2008
  • 방사선치료 시 환자 호흡에 의한 종양의 움직임 영향을 줄이기 위해 사용하는 호흡연동 방사선치료 방법을 폐암 환자의 방사선수술에 적용하였을 경우와 종양의 움직임 영역을 모두 고려하여 계획용표적체적(PTV)을 설정한 일반적인 방사선 수술 경우를 비교, 평가하고자, 각 치료계획에서 계산한 종양 주변의 중요 장기에 조사되는 선량분포의 변화를 분석하고, 그 영향을 고찰하였다. 총 5명의 방사선수술 대상 비소세포성 폐암 환자의 4차원 전산화단층촬영(CT) 모의치료 영상을 획득한 후, 호흡주기 내 50% 위상에서 구성한 CT 영상을 기반으로 호흡연동 방사선치료 방법의 방사선수술 계획을 수립하고, 호흡주기 내 모든 위상에서의 CT 영상들에서 생성한 내부표적체적(ITV)을 기반으로 한 방사선수술 계획을 수립하여 각 계획에서 계산된 중요장기들의 선량체적히스토그램(DVH)을 비교, 분석하였다. 호흡연동 방법을 적용하지 않은 ITV를 기반으로 한 치료계획과 비교한 결과, 호흡연동 방사선치료 방법을 적용하였을 경우의 중요장기 평균선량이 기관지는 평균 $16.88{\pm}9.97%$, 척수는 평균 $34.13{\pm}19.15%$, 흉벽은 평균 $28.42{\pm}18.49%$, 폐의 경우는 평균 $32.48{\pm}16.66%$의 상대적인 감소를 보여, 폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법 적용의 유용성 및 타당성을 확인할 수 있었다.

  • PDF