• 제목/요약/키워드: CT scanning

검색결과 372건 처리시간 0.022초

발포제를 이용한 PET/CT의 유용성 (The Utility of Used a Blowing Agent in PET/CT)

  • 김기진;임재동;유세종;김정호
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.111-117
    • /
    • 2015
  • When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was $61.7{\pm}9.7mm$, horizontal length was $102.5{\pm}17.6mm$ and the vertical length of the Blowing agent group was $74.1{\pm}10.7mm$, horizontal length was $101.5{\pm}14.8mm$ in transverse section. Stomach extension was described as the vertical length of the Water drink group was $109.3{\pm}18.8mm$, horizontal length was $62.7{\pm}18.4mm$ and the vertical length of the Blowing agent group was $123.1{\pm}23.1mm$, horizontal length was $87.6{\pm}14.9mm$ in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.

단일구조 수복용 지르코니아와 Dental CAD/CAM System을 이용한 전악 임플란트 고정성 보철 수복 증례 (Full mouth rehabilitation of a patient using monolithic zirconia and dental CAD/CAM system: a case report)

  • 이상훈;윤형인;여인성;한중석;김성훈
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.196-207
    • /
    • 2018
  • 임플란트의 장기적인 안정을 위해서는 이상적인 위치와 각도로 임플란트를 식립하는 것이 중요하며, 이를 위해서는 정확한 계획에 따른 정확한 수술과 보철이 중요하다. 본 증례에서는 치조골 흡수가 심하게 진행된 환자에서 CT data 및 진단왁스업을 스캔한 data를 이용하여 CT guided surgery를 시행하고, 단일구조 수복용 지르코니아와 CAD/CAM technique을 이용하여 전악 임플란트 고정성 보철로 수복하여 기능 및 심미적으로 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

컴퓨터 단층촬영을 위한 요오드화 조영제 사용으로 인한 부작용 발생의 위험인자 연구 (Risk Factors for Adverse Reactions to Iodinated Contrast Media in Computed Tomography)

  • 강형림;이유정
    • 한국임상약학회지
    • /
    • 제26권1호
    • /
    • pp.40-45
    • /
    • 2016
  • Objective: The increasing use of imaging examinations such as computed tomography (CT) results in increased contrast media use, which increases contrast media-induced adverse reactions (AR). This study investigated the risk factors of ARs to nonionic iodinated contrast media. Methods: This study evaluated patients who were administered iodinated contrast media during CT scanning in Yeouido St. Mary's Hospital in Seoul, Korea in 2012. Among the subjects, those with contrast media-induced ARs were classified as the AR group. The control group included individuals without ARs who were selected through simple random sampling. The effects of sex, age, contrast media type and dose, CT region, previous contrast media administration, allergy history, and comorbidity were analyzed in the AR and control groups. Results: Multivariate logistic regression analyses were performed to evaluate the identified AR risk factors in 103 subjects in the AR group and 412 subjects in the control group. The results confirmed that the risk of developing ARs was significantly higher in females [odds ratio (OR): 2.206; 95% confidence interval (CI): 1.353-3.598], in individuals administered Iohexol (OR: 9.981; 95% CI: 2.361-42.193), in individuals with an allergy history (OR: 3.982; 95% CI: 1.742-9.101), and in individuals with comorbid asthma (OR: 6.619; 95% CI: 1.377-31.826). Most of the ARs were mild and immediate. Conclusion: In patients who were administered contrast media during CT scans, female gender, Iohexol use, allergy history, and asthma were risk factors for ARs. Therefore, special care is required for patients with such risk factors to prevent ARs.

모형물을 이용한 전산화 단층 촬영에서 3차원적 부피측정의 정확성 평가 (Three-Dimensional Volume Assessment Accuracy in Computed Tomography Using a Phantom)

  • 김현수;왕지환;임일혁;박기태;연성찬;이희천
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.268-272
    • /
    • 2013
  • The purpose of this study was to assess the effects of reconstruction kernel, and slice thickness on the accuracy of spiral CT-based volume assessment over a range of object sizes typical of synthetic simulated tumor. Spiral CT scanning was performed at various reconstruction kernels (soft tissue, standard, bone), and slice thickness (1, 2, 3 mm) using a phantom made of gelatin and 10 synthetic simulated tumors of different sizes (diameter 3.0-12.0 mm). Three-dimensional volume assessments were obtained using an automated software tool. Results were compared with the reference volume by calculating the percentage error. Statistical analysis was performed using ANOVA and setting statistical significance at P < 0.05. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were larger than the actual volumes by a common factor depending on slice thickness; in 100HU simulated tumors that had statistically significant, 1 mm slice thickness produced on average 27.41%, 2 mm slice thickness produced 45.61%, 3 mm slice thickness produced 93.36% overestimates of volume. However, there was no statistically significant difference in volume error for spiral CT scans taken with techniques where only reconstruction kernel was changed. These results supported that synthetic simulated tumor size, slice thickness were significant parameters in determining volume measurement errors. For an accurate volumetric measurement of an object, it is critical to select an appropriate slice thickness and to consider the size of an object.

CT 정도관리에서 ACR 팬텀을 이용한 딥러닝 모델 적용에 관한 연구 (A Study on the Application of Deep Learning Model by Using ACR Phantom in CT Quality Control)

  • 최은빈;김시온;최승원;김재희;김영균;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.535-542
    • /
    • 2023
  • This study aimed to implement a deep learning model that can perform quantitative quality control through ACTS software used for quantitative evaluation of ACR phantom in CT quality control and evaluate its usefulness. By changing the scanning conditions, images of three modules of the ACR phantom's slice thickness (ST), low contrast resolution (LC), and high contrast resolution (HC) were obtained and classified as ACTS software. The deep learning model used ResNet18, implementing three models in which ST, HC, and LC were learned with epoch 50 and an integrated model in which three modules were learned with Epoch 10, 30, and 50 at once. The performance of each model was evaluated through Accuracy and Loss. When comparing and evaluating the accuracy and loss function values of the deep learning models by ST, LC, and HC modules, the Accuracy and Loss of the HC model were the best with 100% and 0.0081, and in the integrated model according to the Epoch value, Accuracy and Loss with epoch 50 were the best with 96.29% and 0.1856. This paper showed that quantitative quality control is possible through a deep learning model, and it can be used as a basis and evidence for applying deep learning to the CT quality control.

전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가 (Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment)

  • 허효정;노경호
    • Korean Chemical Engineering Research
    • /
    • 제47권6호
    • /
    • pp.688-694
    • /
    • 2009
  • PCB의 먼지 제거용 세정제로 사용되는 스프레이형 세정제를 선정하여 이에 대한 청정도를 평가하였다. 친환경적인 대체 세정제를 채택하기 위해서는 세정제의 세정성, 환경성, 경제성을 평가하여 체계적인 선정절차에 의거하여 도입 및 적용하여야 한다. 객관적이고 효율적인 세정성 평가방법의 정립이 현시점에서 매우 중요하다. 본 연구에서는 여러 세정성 평가 방법들 중 표면관찰평가법인 SEM-EDX(Scanning Electron Microscopy/Energy-Dispersive X-ray) 분석과 적외선열화상카메라(THERMOVISION A20 model)를 이용하여 청정도를 평가하였다. CT-2770 모델의 사운드카드를 $2{\times}2cm$로 잘라내어 스프레이 세정 전과 후의 청정도를 SEM의 이미지 분석을 통해 관찰할 수 있었고 EDX의 성분분석을 통해 먼지의 제거율을 정량화할 수 있었다. 컴퓨터의 P4T-E 모델의 마더보드와 IPC-A-36 모델의 기판을 사용, 오염물로 먼지와 철가루를 사용하여 열화상카메라로 세정 전, 후의 상온과 $50^{\circ}C$ Oven에 방치된 시간의 차이에 따른 온도의 변화를 비교하였다.

장침 전기자극 시술이 복부지방과 비만지표에 미치는 효과 (The Effect of Electroacupuncture on Abdominal Fat Deposit and Parameters for Obesity)

  • 송성민;송윤경;임형호
    • 한방재활의학과학회지
    • /
    • 제20권2호
    • /
    • pp.113-127
    • /
    • 2010
  • Objectives : This study was performed to evaluate the effect of the electroacupuncture therapy on abdominal fat deposit without diet, exercise and herbal medication. It was also designed to check the changes of free fatty acid in blood and catecholamine in urine to observe the mechanism of the electroacupuncture efficacy. Methods : 10 volunteers over 85 cm(male, 90 cm) in waist circumferences were recruited, and 10 electroacupuncture treatments were applied on their abdominal subcutaneous fat area for 4-5 weeks. We measured anthropometric factors, abdominal fat area with CT scanning, and the changes of free fatty acid in blood and catecholamine in urine before treatment and after the last treatment. Results : In this study, significant changes were shown in weight, waist circumference, waist/hip ratio, body mass index and body fat percent after the electroacupuncture therapy. There were also significant decreases of visceral fat area, visceral/subcutaneous fat area ratio in CT scanning. The blood level of free fatty acid and the urine level of catecholamine were increased after treatments, but the changes were not statistically significant. Conclusions : This study showed the efficacy of the electroacupuncture therapy on the abdominal fat deposit. But significant changes couldn't be found out in free fatty acid and catecholamine. Further studies that compensate for the limitations of this study are required to confirm the mechanism of the electroacupuncture efficacy.

잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구 (Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis)

  • 구은희;권대철;김동성;최천규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권3호
    • /
    • pp.33-39
    • /
    • 2003
  • 잡견의 간흡충증에서 조영기법의 역동적 CT 영상과 MIP 기법을 적용한 자기공명 영상의 질을 비교하여 임상적 적용 가능성을 알아보고자 하였다. 20마리의 잡견(평균 20kg)에 실험적으로 간흡충증을 유발한 후 13주 동안에 간을 중심으로 CT 영상과 MR 영상을 얻었다. CT는 이중나선식방법으로 영상을 획득하였고, bolustracking 방법으로 조영제를 주입하여 arterial phase는 5초 후에 정맥기는 동맥기 scan후 15초에 시작하여 single dynamic scan을 하고, 데이터를 다 단면 영상을 얻기 위해 MnP로 재구성을 하였다. MR 영상은 circularly polarized phased away body coil을 사용하였고, HASTE, FLASH, TSE 기법을 이용하여 모두 2차원 영상을 얻었다. HASTE와 TSE는 해상력을 증가시키기 위하여 interpolation과 지방소거기법을 적용하였다. 데이터를 획득하는 방식으로는 담관을 중심으로 3방향으로 수집한 다음 최대강도투사법으로 재구성하였다. CT와 MR 영상의 평가 방법으로서는 간내담관의 확장, 동맥기에 담관벽의 조영증강, 담관 말단부의 확장, 간의 실질조직묘사, 배경유무를 기점으로 병리학과 의사 1명과 방사선과 의사 3명, 방사선사 5명이 시각적으로 평가를 하였다. MR 영상의 경우 sequence 비교를 위해 정량적분석방법인 CNR과 CR로 평가를 하였다. 감염 후 5마리의 잡견은 죽었으며, 15마리 잡견에서 CT와 MR 검사에서 간내 담관의 만성 확장을 보여 주었다. 조영증강기법인 CT 영상에서는 간 실질조직을 비롯하여 담관벽의 조영증강이 보였고, MR 영상에서는 간내담관 형태와 담관의 말단부의 확장이 MIP 기법을 이용하여 3차원적으로 관찰되었고, CNR과 CR 값이 HASTE($16{\pm}0.83$, 73.3%), TSE($7.06{\pm}3.0$, 62.3%), FLASH($1.19{\pm}0.2$, 6.4%) 순으로 나타났다. CT와 MR 영상은 짧은 검사기법과 다양한 검사기법을 포함하고 있어 간흡충증을 영상화하는데 있어서 진단적 가치가 있다. CT와 MR 영상 검사의 장 단점을 서로 보안하여 검사를 시행한다면 높은 임상적 적용 가능성이 있다.

  • PDF

PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구 (The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT)

  • 도용호;송호준;이형진;이홍재;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Siemens사의 CT 선량 감소 소프트웨어인 IRIS의 적용을 통하여 CT 선량 감소 시 노이즈 감소 효과와 해상력의 보존 그리고 ACCT에 IRIS 각 kernel의 적용 시 SUV 변화를 확인하는데 목적을 두었다. Biograph mCT 40 slice 스캐너를 이용하여 AAPM CT performance phantom, Anthropomorphic chest phantom을 관전압 120 kVp로 고정하고 100-10 mAs까지 15%감소하여 스캔 후 FBP, IRIS 각 kernel을 적용하여 재구성 하여 영상의 노이즈, 해상력, 영상 평가를 시행하였다. NEMA IEC body phantom을 이용하여 55.5 MBq를 background에 주입하고 열소와 배후 방사의 비를 8:1이 되도록 모형을 제작하였다. 120 kVp, 50 mAs 조건으로 1분, 2분, 3분, 4분 스캔하여 영상을 획득한 후 ACCT에 IRIS 각 kernel을 적용하여 기존 FBP 방식을 적용한 SUV와의 평가를 시행하였다. IRIS의 적용 시 기존 FBP 방식에 비하여 45% 선량을 감소하였음에도 불구하고 해상력 저하 없는 노이즈 감소 효과가 확인 되었으며 SUV 평가 실험에서 IRIS의 I70f kernel을 제외하고는 기존 FBP 방식을 통하여 획득된 SUV와 유의한 차이가 나타나지 않았다. 본 연구를 통하여 IRIS 적용 시 기존 FBP 방식에 비하여 CT 피폭선량 감소와 해상력 저하 없는 노이즈 감소 효과를 입증하였으며 IRIS kernel의 적절한 적용을 통하여 PET/CT 검사 시 환자 피폭선량 감소는 물론 FBP 방식에 비하여 우수한 영상의 획득이 가능할 것이라 사료된다.

  • PDF

양전자 방출 핵종(18F)의 감마에너지가 X선 CT영상에 미치는 영향 (Effect of Gamma Energy of Positron Emission Radionuclide on X-Ray CT Image)

  • 김가중;배석환;김기진;오혜경
    • 한국산학기술학회논문지
    • /
    • 제12권10호
    • /
    • pp.4418-4424
    • /
    • 2011
  • 양전자방출 방사성동위원소를 주입한 팬텀에서 방출되는 511keV 에너지의 감마선이 X-선 CT영상에 미치는 영향을 정량적으로 평가하고자 한다. 스캔방법은 증류수를 주입(0 mCi)한 기준영상과 양전자 방출핵종인 $^{18}F$(Fluorine) 의 용량을 1 mCi, 2 mCi, 5 mCi, 10 mCi로 변화시켜 획득된 영상의 CT 번호와 픽셀값을 측정하였다. 양전자 방출핵종($^{18}F$)을 주입한 팬텀 영상의 CT 번호(HU) 측정 결과, 기준물($-7.58{\pm}0.66$ HU), 1 mCi($-9.85{\pm}0.50$ HU), 2 mCi($-10.27{\pm}0.21$ HU), 5 mCi($-11.31{\pm}0.66$ HU), 10 mCi($-13.47{\pm}0.38$ HU)로 물을 채운 기준 영상과 비교하여 10 mCi에서는 5.89 HU, 5 mCi에서는 3.73 HU, 2 mCi에서는 2.69 HU, 1 mCi에서는 2 HU가 감소하였다. 팬텀 영상의 픽셀 값은 기준물($-2.70{\pm}0.75$), 1 mCi($-4.72{\pm}0.58$), 2 mCi($-6.01{\pm}0.78$), 5 mCi($-6.10{\pm}0.84$), 10 mCi($-8.20{\pm}0.60$)로 기준물영상과 비교한 픽셀 값의 변화는 10 mCi에서는 5.50, 5 mCi에서는 3.40, 2 mCi에서는 3.10, 1 mCi 에서는 2.02가 감소하는 것을 알 수 있었다. 본 실험을 통해 양전자 방출핵종($^{18}F$)의 용량(Dose) 증가에 따라 CT번호와 영상의 픽셀 값은 비례적으로 감소하였으며 감소폭 또한 비슷한 값을 나타냈다. 이에 PET/CT의 정도관리 항목에 양전자 방출핵종으로 인한 X선 CT 영상의 변화 정도와 그에 따른 적합기준을 마련하고 주기적 관리가 이루어져야 할 것이다.