• Title/Summary/Keyword: CT scan range

Search Result 99, Processing Time 0.029 seconds

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

Outcomes in the Management of Spontaneous Cerebellar Hemorrhage

  • Moon, Kang-Seok;Park, Hyung-Ki;Yoon, Seok-Mann;Bae, Hack-Gun;Yun, Il-Gyu;Choi, Soon-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.234-238
    • /
    • 2006
  • Objective : The operative indications on cerebellar hemorrhage have been controversial especially when the patient condition is grave. Therefore we investigated whether it can be justifiable if we perform the surgery in poor clinical grade. Methods : Clinical records and computerized tomography[CT] films of the 89 patients, who were undergone hospital treatment due to spontaneous cerebellar hemorrhage between May 1997 and May 2004, were retrospectively researched. Results : The study population consisted of 36 males and 53 female patients. The mean age was 65years [range $23{\sim}89$]. As a result of treatment, the patients, whose Glasgow coma scale[GCS] score were higher, showed better outcomes [p=0.001]. 13 patients [14.6%] were below 5 in GCS score and 10 patients of these were operated. Among 10 patients, 4 patients [40%] showed good outcome and 5 patients [50%] had been dead. 3 patients [60%] of these dead patients had the findings of intraventricular hemorrhage, fourth ventricular obliteration and hydrocephalus in CT scan. Conclusion : This study suggests that operation may be justifiable in clinically poor grade patient with spontaneous intra cerebellar hemorrhage.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Evaluation of the Feasibility of Applying Metabolic Target Volume in 4D RT Using PET/CT Image (4D RT에서 PET/CT Image를 이용한 Metabolic Target Volume 적용의 유용성 평가)

  • Kim, Chang-Uk;Chun, Keum-Sung;Huh, Kyung-Hoon;Kim, Yeon-Shil;Jang, Hong-Seok;Jung, Won-Gyun;Xing, Lei;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.174-182
    • /
    • 2010
  • In this study, we evaluated feasibility of applying MTV (Metabolic Target Volume) to respiratory gated radiotherapy for more accurate treatment using various SUV (Standard Uptake Value) from PET images. We compared VOI (Volume of Interest) images from 50%, 30% and 5% SUV (standard uptake volume) from PET scan of an artificial target with GTV (Gross Tumor Volume) images defined by percentage of respiratory phase from 4D-CT scan for respiratory gated radiotherapy. It is found that the difference of VOI of 30% SUV is reduced noticeably comparing with that of 50% SUV in longitudinal direction with respect to total GTV of 4D-CT image. Difference of VOI of 30% SUV from 4D-PET image defined by respiratory phase from 25% inhalation to 25% exhalation, and GTV from 4D-CT with the same phase is shown below 0.6 cm in maximum. Thus, it is better to use 4D-PET images than conventional PET images for applying MTV to gated RT. From the result that VOI of 5% SUV from 4D-PET agrees well with reference image of 4D-CT in all direction, and the recommendation from department of nuclear medicine that 30% SUV be advised for defining tumor range, it is found that using less than 30%SUV will be more accurate and practical to apply MTV for respiratory gated radiotherapy.

An Extracting and Indexing Schema of Compressed Medical Images (축소변환된 의료 이미지의 질감 특징 추출과 인덱싱)

  • 위희정;엄기현
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2000.04a
    • /
    • pp.328-331
    • /
    • 2000
  • In this paper , we propose a texture feature extraction method of reduce the massive computational time on extracting texture, features of large sized medical such as MRI, CT-scan , and an index structure, called GLTFT, to speed up the retrieval performance. For these, the original image is transformed into a compressed image by Wavelet transform , and textural features such as contrast, energy, entropy, and homogeneity of the compressed image is extracted by using GLCM(Gray Level Co-occurrence Metrix) . The proposed index structure is organized by using the textural features. The processing in compressed domain can give the solution of storage space and the reduction of computational time of feature extracting . And , by GLTFT index structure, image retrieval performance can be expected to be improved by reducing the retrieval range . Our experiment on 270 MRIs as image database shows that shows that such expectation can be got.

  • PDF

A Case Report of Chylous Mesenteric Cyst (유미성 장간막 낭종 1예 보고)

  • Joo, In-Ho;Chun, Yong-Soon;Lee, Nan-Joo;Yoon, Won-Hwa
    • Advances in pediatric surgery
    • /
    • v.14 no.1
    • /
    • pp.98-103
    • /
    • 2008
  • Chylous mesenteric cyst is a rare variant of mesenteric cystic lesions. Pathologically there is lack of communication of the main lymphatic vessels, resulting in cystic mass formation. Clinical presentation is diverse and can range from an incidentally apparent abdominal mass to symptoms of an acute abdomen. A 5-year-old girl presented with abdominal distension without pain. CT scan showed a huge and thin-walled cystic mass without solid portion. Laparotomy showed a $20{\times}18cm$ sized huge mesenteric cyst containing chylous fluid. Pathological diagnosis was cystic lymphangioma.

  • PDF

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Influences of Anesthetics in term of Computed Tomography Bronchial Lumen to Pulmonary Artery Diameter Ratio in Beagle Dogs (비글견의 컴퓨터단층영상에서 기관내강과 폐동맥 직경비율의 마취제에 따른 영향평가)

  • Lim, Jong-su;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.6-9
    • /
    • 2016
  • Bronchoarterial (BA) ratio is a commonly used criterion to define airway dilatation despite the lack of normative human and animals. The objective of our study was to compare the range of normal bronchial to accompanying arterial diameter ratio with previous reports on CT scan of the thorax in dogs and assess influence anesthetics on BA ratio in dogs. Dogs undergoing multidetector CT scan of the chest for nonpulmonary conditions at a single center were prospectively identified. High-resolution reconstruction was performed on those included and both airway lumen and vessel diameters were measured in the lobar bronchi of the left cranial (cranial and caudal parts), right cranial, right middle, left caudal, and right caudal lung lobes. Eight dog were included; Mean of the mean BA ratios was $1.43{\pm}0.24$ (95% CI = 1.36 - 1.50) in inhalation anesthetic group. In propofol group, the mean of the mean BA ratios was $1.13{\pm}0.29$ (95% CI = 1.04 - 1.22). In medetomidine group, the mean of the mean BA ratios was $0.89{\pm}0.19$ (95% CI = 0.83 - 0.95). Comparing individual lobes within anesthetic category, there was no signicant difference in mean BA ratio between lung lobes or between dog according to inhalation, propofol, and medetomidine group (P = 0.630, P = 0.878, and P = 0.508, respectively). The BA ratio in these clinically normal dogs was consistent and may be a useful tool in evaluating for bronchiectasis on CT images. However, some different criteria for bronchiectasis were applied by the anesthetic methods.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF